Nilfisk-Advance America AX 650 manual PICK-UP Tool Maintenance, Spray Nozzle Maintenance

Page 12

12 ENGLISH

PICK-UP TOOL MAINTENANCE

Check the pick-up tools daily. Remove any built-up string, hair or carpet fibers.

SPRAY NOZZLE MAINTENANCE

Remove the spray nozzles once a week. Soak the nozzles overnight in a vinegar and water solution to remove chemical deposits.

LUBRICATING THE MACHINE

Once a month (or every 30 hours), lubricate all pivot points on the pick-up tool assembly. For best results, use a spray silicone lubricant.

Once a month, pump grease into the grease fittings on the caster wheels until it seeps out around the bearing. Wipe off the excess grease to avoid staining carpet.

CLEANING THE VACUUM MOTOR FILTERS

Clean the vacuum motor filters daily with compressed air. For extremely dirty filters, wash with warm, soapy water and rinse thoroughly with clean water. Allow the filters to dry completely before re-installing in the machine. MAINTENANCE NOTE: Keep a second set of filters on hand to use while first set is drying.

ADJUSTING THE BRUSH HEIGHT

Simply turn the Brush Height Adjustment Knob (19) clockwise to raise and counter-clockwise to lower the brush deck. NOTE: The Brush Pressure Indicator (8) should read 8-15 amps when properly adjusted.

POWER BRUSH MAINTENANCE

Check the brush daily. Remove any built-up string, hair or carpet fibers. Check the bristle length. Have a service technician change the brush when the brush bristles are worn to 1/2 inch (12.7 mm).

REMOVING THE BRUSH

CAUTION!

Turn the key switch off (O) and remove the key, before changing the brushes, and before opening any access panels.

1Turn the Master Key Switch OFF and raise the Brush Deck.

2See figure below. Unsnap Latch (A), remove Pin (B) and Brush Access Door (C). Slide the brush out of the brush deck housing.

3To reinstall, slide the brush under the brush deck housing, make sure the end with the large slots cut into it is inserted first.

4Reach under the left side of the brush deck to guide the end of the brush onto the drive lug (E). Push in and turn the brush until it is firmly seated on the drive lug.

5IMPORTANT! Make sure that the Bearing Block (D) is seated securely in the door and orientated as shown for “old style (F)”, “new style

(G)” machines have the bearing block attached to the access door. Hold the end of the brush up while re-installing Brush Access Door (C) to ensure that the Bearing Block on the inside of the door is securely seated in the end of the brush.

6Re-install Pin (B) and re-secure Latch (A). Latch should secure easily. If it has to be forced, recheck the position of the brush.

￿

￿

￿

 

 

￿

￿

 

 

 

 

￿

￿

 

 

￿

 

￿

 

￿

 

￿

 

 

￿

 

 

12 - FORM NO. 56041551 - AquaMAX/ AX 650

Image 12
Contents AquaMAX Table of Contents EnglishParts and Service IntroductionName Plate Uncrate the MachineImportant Safety Instructions Consignes DE Securite Importantes Know Your Machine English Master Key Switch 4 Main power switch Functional Description of ControlsInstalling the Batteries Filling the Solution TankBefore Using the Aquamax / AX Plan for CleaningUsing Attachments Operating the MachineAfter Using the Machine Maintenance ScheduleWeekly Monthly Yearly PICK-UP Tool Maintenance Spray Nozzle MaintenanceCleaning the Vacuum Motor Filters Adjusting the Brush HeightChecking the Battery Water Level Battery MaintenanceBattery Testing Charging the BatteriesAMP Control Circuit Circuit Breaker AMP Wheel Drive Circuit BreakerAMP Brush Drive Circuit Breaker AMP Vacuum Motor Circuit BreakerPage Page Page Type AX Deklaracija EU o skladnosti Prehlásenie o súlade EÚ 2006