12 ENGLISH
PICK-UP TOOL MAINTENANCE
Check the
SPRAY NOZZLE MAINTENANCE
Remove the spray nozzles once a week. Soak the nozzles overnight in a vinegar and water solution to remove chemical deposits.
LUBRICATING THE MACHINE
Once a month (or every 30 hours), lubricate all pivot points on the
Once a month, pump grease into the grease fittings on the caster wheels until it seeps out around the bearing. Wipe off the excess grease to avoid staining carpet.
CLEANING THE VACUUM MOTOR FILTERS
Clean the vacuum motor filters daily with compressed air. For extremely dirty filters, wash with warm, soapy water and rinse thoroughly with clean water. Allow the filters to dry completely before
ADJUSTING THE BRUSH HEIGHT
Simply turn the Brush Height Adjustment Knob (19) clockwise to raise and
POWER BRUSH MAINTENANCE
Check the brush daily. Remove any
REMOVING THE BRUSH
CAUTION!
Turn the key switch off (O) and remove the key, before changing the brushes, and before opening any access panels.
1Turn the Master Key Switch OFF and raise the Brush Deck.
2See figure below. Unsnap Latch (A), remove Pin (B) and Brush Access Door (C). Slide the brush out of the brush deck housing.
3To reinstall, slide the brush under the brush deck housing, make sure the end with the large slots cut into it is inserted first.
4Reach under the left side of the brush deck to guide the end of the brush onto the drive lug (E). Push in and turn the brush until it is firmly seated on the drive lug.
5IMPORTANT! Make sure that the Bearing Block (D) is seated securely in the door and orientated as shown for “old style (F)”, “new style
(G)” machines have the bearing block attached to the access door. Hold the end of the brush up while
6
|
| |
|
| |
|
| |
|
| |
| ||
| ||
| ||
|
| |
|
|
12 - FORM NO. 56041551 - AquaMAX™ / AX 650