14 ENGLISH
6 AMP CONTROL CIRCUIT CIRCUIT BREAKER
When the Control Circuit Circuit Breaker (15) trips, push the button to reset the circuit breaker.
If the circuit breaker trips repeatedly, call your local
20 AMP WHEEL DRIVE CIRCUIT BREAKER
When the Wheel Drive Circuit Breaker (15) trips, check to see if there is debris wrapped around the wheel axle. Remove the debris from the axle. Have the wheel drive motor checked for worn out brushes; repair or replace the motor if necessary. Push the button to reset the circuit breaker.
If the circuit breaker trips repeatedly, call your local
20 AMP BRUSH DRIVE CIRCUIT BREAKER
When the Brush Drive Circuit Breaker (15) trips, check to see if the brush height is set too low or if there is debris wrapped around the brush. Adjust the brush height or remove the debris from the brush. Push the button to reset the circuit breaker.
If the circuit breaker trips repeatedly, call your local
40 AMP VACUUM MOTOR CIRCUIT BREAKER
When the Vacuum Motor Circuit Breaker (15) trips, check the Vac Motor Filters (32) and clean or replace if necessary. Have the vacuum motors checked for worn out bearings and/or brushes or bearing failure. Repair or replace the motors if necessary. Push the button to reset the circuit breaker.
If the circuit breaker trips repeatedly, call your local
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model |
| AquaMAX™ / AX 650 |
Model No. |
| 56212000 / 56212260 |
Voltage,batteries | V | 36V |
Battery capacity | Ah | 238 |
Protection grade |
| IPX3 |
Sound power level as per ISO 3744 (at operator) | dB(A)/20µPa | 76 |
Gross weight (with acc. and batteries, full tank) | lbs / kg | 1,171 / 531 |
Vibrations at the Hand Controls | m/s2 | <2,5m/s2 |
14 - FORM NO. 56041551 - AquaMAX™ / AX 650