SAFETY TIPS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70- 1999), including
Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the
Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
5. Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.
8. To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support.
9. (Mounting must support at least 35 lbs.)
10. Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
11. Attach the mounting bracket using only the hardware supplied with the outlet box.
12. To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
13. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
14. NEVER place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of
15. Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
|
| Phillips Screwdriver | TOOLS REQUIRED | Pliers |
| 1 | Wire Cutters | ||
| 2 |
|
|
| Unpack and inspect fan carefully to |
| Before you begin installing the fan, Switch power off |
| ||||
|
|
| ||||||
|
| to prevent power from being switched on accidentally. |
| |||||
| be certain all contents are included. |
| at Service panel and lock service disconnecting means |
| ||||
|
| When the service disconnecting means cannot be |
| |||||
| (See exploded view parts lists.) |
| locked, securely fasten a prominent warning device, |
| ||||
|
| such as a tag, to the service panel. |
| |||||
| 4 |
|
| 5 |
| METAL |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| Install mounting brackets to outlet |
|
|
| Install downrod into metal canopy and |
|
|
|
|
|
| ||
|
| |||||
| box in ceiling using the screws and |
|
|
| ceiling canopy. Feed motor wires through |
|
| washers provided with the outlet |
|
|
| downrod / canopy assembly. |
|
| box. |
|
|
|
|
|
Step Ladder
3
Before installing this fan make sure the outlet box is properly installed to the house structure. To reduce the risk of fire, electric shock, or per- sonal injury, mount to outlet box or supporting system acceptable for fan support.
(Mounting must support at least 35 lbs.)
6
Feed motor lead wires through downrod/canopy assembly and insert downrod into motor yoke. Next, insert clevis pin through yoke and down- rod and secure with cotter pin. (see Inset) Tighen both yoke set screws to further secure downrod.