Mad Catz 5MPRA6F3-156, 5MPRA6E-148, 5MPRA6E3-148, 5MPRA6F-156 To the potential for personal injury

Page 3

IMPORTANT SAFETY INSTRUCTIONS

Always follow basic safety pre- cautions with this equipment, in- cluding the following.

To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.

This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently installed pool is con- structed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassem- bled for storage and reassembled to its original integrity.

SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL

INSTRUCTIONS!

This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert

to the potential for personal injury.

warns about hazards that will cause death, serious personal injury, or major property damage if ignored.

warns about hazards that can cause death, serious personal injury, or major property damage if ignored.

warns about hazards that will or can cause minor personal injury or property damage if ignored.

NOTICE indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on equip- ment. Keep safety labels in good condition; replace if missing or damaged.

Incorrectly installed or tested equipment may fail, causing severe injury or property damage.

Read and follow instructions in owner's manual when installing and operating equipment. Have a trained pool professional per-

form all pressure tests.

1.Do not connect system to a high pressure or city water system.

2.Use equipment only in a pool or spa installation.

3.Trapped air in system can cause explosion. BE SURE all air is out of system before operating or testing equipment.

Before pressure testing, make the following safety checks:

Check all clamps, bolts, lids, and system accessories before testing.

Release all air in system before testing.

Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-m) torque for testing.

Water pressure for test must be less than 25 PSI (7.5 kg/cm2).

Water Temperature for test must be less than 100o F. (38o C).

Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. Remove trap lid and retighten hand tight only.

NOTICE: These parameters apply to Sta-Rite equipment only. For non-Sta-Rite equipment, consult manufacturer.

3

Image 3
Contents DYNA-GLASTMCENTRIFUGAL Pumps With Integral Trap Limited Warranty To the potential for personal injury Before pressure testing, make the following safety checksTeflon Taping Instructions InstallationPiping FittingsServ. to Motor Dist. in Ft. M Grounding/Bonding WiringElectrical VoltageSupervision OperationPriming Pump Storage/WinterizingStartup For Winterized Equipment Draining PumpPump Service Disconnect power to pump motorPump Dissasembly/Removing Old Seal Troubleshooting Guide Pump Reassembly/Installing New SealSuction leaks/lost prime Electrical Clogged pipe/trap/impeller, worn impellerBOX a