Mad Catz 5MPRA6F-156, 5MPRA6E-148, 5MPRA6E3-148 Pump Service, Pump Dissasembly/Removing Old Seal

Page 9

Hazardous voltage.

Can shock, burn,

or cause death.

Disconnect power

before working

on pump or motor.

Figure 6

PUMP SERVICE

Pump should only be serviced by qualified personnel.

Be sure to prime pump (Pg. 7) before starting.

Before removing trap cover:

1.STOP PUMP before proceeding.

2.CLOSE GATE VALVES in suction and discharge pipes.

3.RELEASE ALL PRESSURE from pump and piping system.

To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before working on pump or motor.

Aside from lubricating trap cover “O” Ring, no lubrication or regular mainte- nance is needed beyond reasonable care and periodic cleaning of strainer basket.

If shaft seal is worn or damaged, repair as follows:

Pump Dissasembly/Removing Old Seal

Disconnect power to pump motor.

Be sure gate valves on suction and return piping are closed before start-

ing work.

Release all pressure by opening all vents before starting work.

1.Drain pump by removing drain plugs on bottom of pump body and trap body.

2.Be sure there is no pressure in trap body; remove cover (unscrew by turn- ing counterclockwise).

3.Remove 6 nuts, lockwashers and flat washers holding seal plate to pump body. Pull seal plate and motor away from pump body. (You may have to CAREFULLY use a screwdriver to separate body from seal plate.)

4.Remove seven screws and washers holding diffuser to seal plate. Remove diffuser.

5.Remove motor canopy. Being careful not to touch capacitor terminals, loosen capacitor clamp and move capacitor to one side.

6.Hold shaft with 7/16" open-end wrench on motor shaft flats.

7.Unscrew impeller from shaft (turn counterclockwise when facing it). NOTICE: On 3 phase models, remove impeller screw (left hand thread - turn clockwise) and gasket before removing impeller. Inspect gasket for damage, cracks, etc. Replace if damaged.

8.Remove four screws holding seal plate to motor.

9.Place seal plate face down on flat surface and tap out ceramic seat (Fig. 6).

10.Remove slinger from motor shaft and inspect for damage or abrasion.

11.Clean seal cavity in seal plate and clean motor shaft.

9

Image 9
Contents DYNA-GLASTMCENTRIFUGAL Pumps With Integral Trap Limited Warranty To the potential for personal injury Before pressure testing, make the following safety checksTeflon Taping Instructions InstallationPiping FittingsServ. to Motor Dist. in Ft. M Electrical WiringVoltage Grounding/BondingPriming Pump OperationStorage/Winterizing SupervisionStartup For Winterized Equipment Draining PumpPump Service Disconnect power to pump motorPump Dissasembly/Removing Old Seal Troubleshooting Guide Pump Reassembly/Installing New SealSuction leaks/lost prime Electrical Clogged pipe/trap/impeller, worn impellerBOX a