Lifebreath 40VENTAC, 60DHW(T), 60VENTAC, 60DHWDF(T), 60DHWH(T), 4TONVENTAC Description and Purpose

Page 4

Description and Purpose

IMPORTANT NOTE

The purpose of this manual is to act as an installation guide only for the LIFEBREATH Clean Air Furnace. Manufacturers' instructions for other components, such as the water heater/boiler, must be followed.

All national and local code requirements must be met when installing a LIFEBREATH Clean Air Furnace. Be sure to consult the proper authorities.

Note: Temperatures greater than 130 °F (54°C) pose a serious risk of scalding individuals running domestic hot water for potable use.

This appliance complies with IAS Canada Inc. Requirement CR95-003, Additional Requirements for Fan Coil Units for use with Potable Water Heaters.

All piping and components connected to this appliance shall be suitable for use with potable water.

Toxic chemicals, such as used for boiler treatment, shall not be introduced into the potable water heater system.

When using this system, and water for space heating, is required to be at a higher temperature than for other uses, an anti-scald valve shall be used to ensure water for other uses is reduced in temperature to minimize a scald hazard potential.

Combining two or more end uses such as space heating and the heating of domestic hot water in a single system has the potential to increase efficiency and reduce overall capital costs. However, the proper design, installation, and commissioning of these systems is critical if these advantages are to be realized.

This manual provides a guideline of good engineering practice in the design, installation and commissioning of Integrated Combo Systems. The guidelines in the manual are designed for residential forced warm air Integrated Combo Systems which utilize domestic water heaters or boilers and the LIFEBREATH furnace. Heating and cooling loads shall be calculated in accordance with recognized Residential Heat Loss and Heat Gain Calculation methods. Duct design shall comply with recognized Residential Air System Design methods. This manual provides worksheets to be used for the purpose of sizing residential water heaters and the combo furnace.

The LIFEBREATH Clean Air Furnace is a volume ventilator system and is not intended to replace a fully ducted Heat Recovery Ventilation (HRV) system. Independent exhaust fans should be used for bathrooms and kitchen range hoods.

4

Image 4
Contents OPERATION, Sizing and Installation Manual Table of Contents Introduction Description and Purpose Combo System Basic Principles Closed/Open Combo SystemCall for Space Heating Only Operation Call for Domestic Hot Water and Space Heating OperationAir System Water PipingManual Valves Shut Off Valves Drain ValveThrottling Valve Check ValvesExpansion Tanks ColdAnti-Scald Valve Off Season Circulation ControlsAir Handler Return Air Temperature Air Handler Temperature RiseWater Heater Thermostat Room ThermostatDesign vs. Field Conditions Water System PressuresHead Pressure Flow RateDimensions & Clearances WarrantyModel 40DHW Up Flow Filters CaseModel 60DHW Up Flow 60DHWModel 40DHWDF Down Flow 40DHWDFModel 60DHWDF Down Flow 60DHWDFModel 40DHWH Horizontal 40DHWHModel 60DHWH Horizontal 60DHWHHigh CFM Lower Btuh Output 4TONDHWCore Filters Case Model 40VENTAC40VENTAC Model 60VENTAC 60VENTACModel 4TONVENTAC 4TONVENTACDuct Connections Locating The UnitOption 1 Ventilation Ports Off Left Side Horizontal Version Option 2 Ventilation Ports Off Right SideDucting Locating Intake Weatherhood Locating the Exhaust WeatherhoodsOutside Ducting the Weatherhoods Locating WeatherhoodPitot Tube Air Flow Balancing Balancing ProcedurePrior to balancing, ensure that Pitot Tube and Gauge Placement of the Pitot TubeBalancing Collar Instructions Drain Line HRV Drain Line DiagramPiping Plumbing Water HeaterClean Air Furnace Wiring Diagram ElectricalOptional Dehumidistat Start-Up Procedure Following conditions must be met prior to start-upOptional Circulation Timer Models OperationHeating/Cooling VentilationTroubleshooting Lack of heatPump is noisy HRV core freezes upDuring cooling cycle, hot water circulates through the coil Water sits in drain pipesCondensation/ice forming inside ventilation ducts Humidity levels are too lowWater Pump Performance Specifications System CommissioningWorksheet for Integrated Combo System Design Part a Design Load Specifications Method a domestic hot water usage for C.1 Part D Proving Required Water Flow Commissioning of Integrated Combo System HRV Balancing McCormick Blvd. London, Ontario N5W 4C8

40DHWDF(T), 4TONVENTAC, 60VENTAC, 40VENTAC, 60DHWH(T) specifications

Lifebreath is a leading manufacturer specializing in indoor air quality solutions, with their series of heat recovery ventilators tailored for both residential and commercial applications. Among their advanced systems, the Lifebreath 60DHW(T), 60DHWDF(T), 4TONVENTAC, 40DHW(T), and 40DHWDF(T) provide exceptional ventilation performance alongside energy efficiency.

The Lifebreath 60DHW(T) and 60DHWDF(T) models are designed for larger spaces, featuring an impressive air flow rate of 60 CFM, making them ideal for homes and businesses that require a robust ventilation solution. These units incorporate a state-of-the-art heat exchange core, allowing for the transfer of heat from outgoing stale air to incoming fresh air, thereby minimizing energy loss.

The significant advantage of Lifebreath's 60DHW series lies in its dual-fan operation, which delivers balanced air flow while maintaining a comfortable indoor climate. Both models are equipped with advanced filtration systems, providing effective capture of airborne pollutants and allergens, promoting optimal air quality.

Moving to the Lifebreath 4TONVENTAC, this unit offers a unique combination of ventilation and cooling functionalities, making it suitable for environments with varying weather conditions. With a 4-ton capacity, it is perfect for larger commercial establishments. The 4TONVENTAC employs innovative technology for efficient energy use, incorporating variable speed drives to adapt to changing ventilation demands, ensuring maximum energy conservation and performance.

The Lifebreath 40DHW(T) and 40DHWDF(T) are perfect for smaller residential applications. With an airflow capacity of 40 CFM, these units maintain comfort without over-ventilating. Similar to the 60DHW models, they feature the same exceptional heat exchange technology to promote energy savings. The 40DHW series also includes user-friendly controls and monitoring features, enabling homeowners to adjust settings for optimal performance based on their specific needs.

A common characteristic across all these models is Lifebreath’s commitment to durability and reliability. Made from high-quality materials, they are built to withstand varying environmental conditions while providing long-lasting service. With easy installation and low maintenance requirements, these heat recovery ventilators prove to be a smart investment for users looking to improve their indoor air quality while reducing energy costs.