Lifebreath Official Manual and Specifications for 95 MAX

Page 17

DIMENSIONS 95MAX inches (mm)

 

 

18.5"

 

 

(470 mm)

24.5"

(622 mm)

Removably

Heat Recovery

Core

 

 

Drain Pan

 

 

Drain spout

 

 

FRONT

 

 

 

Hanging

knockout for

straps (4)

 

 

Threaded

side mounting of

 

 

 

 

inserts (4)

EXHAUST return port

 

 

 

 

at corners

6" round collar

 

 

 

 

 

 

 

 

 

 

converted to oval

18.5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(470 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fresh air

 

 

 

 

 

 

 

 

 

 

from outside

 

 

 

 

 

 

 

 

 

 

5" round collar

 

 

 

 

 

 

 

 

 

 

SUPPLY

 

 

 

 

 

minimum

 

 

 

 

Fresh air

 

 

 

 

 

 

 

 

 

to building

 

 

 

 

 

18 inches (459 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

6" round

 

 

 

 

 

required for

 

 

 

 

 

 

 

 

 

 

 

 

 

(conv. to oval)

 

 

 

 

 

service access

 

 

 

 

 

 

 

 

 

 

 

 

 

collar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16"

(406 mm)

SIDETOP

EXHAUST

Stale Air

to outside

5" round collar

EXHAUST Return air from building

Choice of port location Knockouts on top and side of unit (use 1 only) 6" round (conv. to oval) collar supplied

95 MAX Port Specifications

The 95 Max Heat Recovery Ventilator (HRV) has been designed to allow the installer to choose between two possible positions on the cabinet for the INDOOR EXHAUST (return from building) port. Illustrations in this manual show standard (side mounted) port location . The same specifications apply to both 95 Max setups, regardless of which port position is selected.

In order to make the 95 Max as space efficient as possible, the INDOOR supply and return ports are converted from round to oval shape. Overall size of the port remains the same. Simply bend a standard duct fitting to the correct shape, and attach to the oval port using the same method as for a round port.

(6 inch)

diameter

Same Circumference

HEAT

 

 

 

 

 

RECOVERY

VENTILATORS

(HRVs)

HEAT

RECOVERY

VENTILATORS (HRVs)

 

 

 

 

 

 

 

 

SIDE MOUNTED PORT

TOP MOUNTED PORT

standard location

alternate location

Variable Port Location

Variable Port Location / Installation (Model 95 Max only)

The exhaust return port collar is not factory installed. Installer may choose either side mounted or alternate top mounted port by simply removing one of the two knock-out plates and attaching a port collar (supplied). To remove knock-out plate, insert a utility knife into the knock-out slits and trace them completely to puncture protective film underneath. Then, cut the solid tabs between the slits, using tin snips or side cutters, and remove the knock-out plate. If any protective film still blocks the opening, remove it now.

Round port bent to oval

95 MAX Air Flow

Stale air enters the FRONT RIGHT side port. The air will pass down the front half of the core, then up the back half of the core and out the RIGHT REAR port.

Fresh outdoor air will enter the LEFT REAR port and pass down the back half of the core. It will then pass up the front half of the core, and out the LEFT FRONT port. This unique configuration allows the air to actually travel through the core twice, making the 95 MAX almost as efficient as a double core unit.

17

Image 17
Contents 200ERVD Contains95MAX Table of Contents ERV Questions & Answers Page Engineering Data Model 95MAXModel 155MAX Dimensions 155MAX inches mmModel 200MAX Dimensions 200MAX inches mmModel Maxtop Dimensions Maxtop inches mmModel 195DCS Dimensions 195DCSThermally CONDUCTIVE, Patented Aluminum Core Model 300DCSModel 200ERV Dimensions 200ERV inches mmModel 200ERVD Dimensions 200ERVDFunction & Control To select mode of operation for ControlAir NEW! AIR Sentry AIR Quality Sensor Optional Remote ControlsUsing the Dehumidistat MAX Port Specifications Location InstallationInstalling AIR Ducts Dampers and Grilles Supply AIR DuctingInstallation Diagrams Simplified Installation Supply/Return Method Fully Dedicated System Pitot Tube AIR Flow Balancing Balancing Collar Instructions Inspect Exterior Hoods at least once a month Maintenance Routine for ERV for HRV, see previous Occupant Symptom Cause SolutionTechnical Bulletin Residential Wiring Diagram McCormick Blvd. London, Ontario N5W 4C
Related manuals
Manual 10 pages 11.12 Kb Manual 32 pages 15.63 Kb Manual 12 pages 19.73 Kb

MAXTOP, 195DCS, 200ERVD, 200ERV, 300DCS specifications

Lifebreath is well-known for its innovative heat recovery ventilators that enhance indoor air quality while conserving energy. Among their acclaimed models, the Lifebreath 150SP, 200MAX, 150MAX, and 200STD stand out for both their functionality and design, delivering optimal performance for various residential and commercial applications.

The Lifebreath 150SP is designed for spaces requiring effective air exchange while maintaining energy efficiency. This model boasts a compact design, making it ideal for smaller homes or apartments. One of its main features includes a top-mounted control panel with a user-friendly interface, allowing for easy adjustment of settings. Equipped with a high-efficiency heat exchanger, the 150SP effectively transfers heat from the outgoing stale air to the incoming fresh air, minimizing energy loss. Additionally, the unit operates quietly, ensuring that comfort is not compromised.

On to the 200MAX, this model is engineered for larger spaces. With increased airflow capacity, it ensures consistent air quality in bigger areas while optimizing energy consumption. The 200MAX features advanced filtering systems that capture dust, pollen, and other allergens, promoting a healthier indoor environment. Its built-in defrosting system operates automatically, enhancing efficiency during colder months. The 200MAX also supports optional accessories, such as a programmable timer and an energy recovery ventilator, allowing users to customize performance to meet specific needs.

The Lifebreath 150MAX pairs the efficiency of the 150SP with added versatility. This model is suitable for mid-sized spaces and comes equipped with a dual motor system. This unique feature provides users with the flexibility to adjust airflow independently, accommodating varying room conditions. The 150MAX excels in both heating and cooling modes, ensuring comfort year-round.

Finally, the Lifebreath 200STD offers a straightforward approach to ventilation without compromising on performance. Designed for standard residential applications, the 200STD is easy to install and maintain, featuring a washable pre-filter. This model is energy efficient and operates quietly while delivering excellent air exchange rates, making it perfect for families seeking reliable indoor air management.

In conclusion, the Lifebreath range—150SP, 200MAX, 150MAX, and 200STD—showcases superior design and cutting-edge technology. With their focus on energy efficiency, user comfort, and adaptable features, Lifebreath models uphold a promise of high indoor air quality and sustainable living. These systems not only contribute to a healthier environment but also reduce energy costs, making them an ideal investment for any modern building.