hussman rhr-hex manual Leveling, Cut & Plan Views

Page 3

Rev.9911

Cut & Plan Views

501/4" 329/16"

Food

Light

Light

Food

Warmer

Warmer

 

 

Warming

18"

Griddle

 

 

 

 

281/2" (19 1/2")

 

 

 

 

 

 

 

 

 

"

 

 

 

 

Control Panel

 

 

 

 

 

 

 

 

 

 

211/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

431/4" (251/8")

 

101/2"

 

101/2"

 

 

 

 

 

 

 

 

 

641/4" (471/8")

 

 

 

 

 

 

 

 

 

 

 

 

RHR-HEX 6' & (4')

Self-Service Hot

 

 

 

Food

 

 

 

12"

Warmer

 

 

 

183/4"

 

 

 

 

 

58"

Warming

13"

281/2" (191/2")

 

Griddle

 

 

 

 

 

9/16"

 

 

 

 

32

16"

Control

 

 

Panel

 

 

 

211/

 

 

 

 

101/2"

431/4" (251/8")

101/2"

 

 

541/4" (473/8")

 

RHR2-HEX 6' & (4')

Self-Service Hot

Scale = 1/2"

/8")

/8")

/8"

27"

/4834" (275

3 8"/65(47

47

3

 

3

 

371/2" (261/2")

773/8" (547/16")

RHR-HEX 6' & (4')

PLAN VIEW

121/4"

ELEC.

MECHANICAL

STUB UP AREA

4" X 6"

RHR SQUARE

Self Service Hot Food

/16" (333/8")

 

(245/8")

11

8"

23

14

 

/

 

1

2011/16"

2'-21/2"(3'-11/2")

4'-67/16"(6'-53/8")

RHR-HALF-HEX-4' (6')

Self-Service Hot

Installation

IMPORTANT: It is imperative that cases be leveled front to back and side to side prior to joining.A level case is necessary to ensure proper operation.

LEVELING

1.Check floor where cases are to be set to see if it's level. Determine where the highest part of the floor is. Cases will be shimmed off this point. Using case blueprints, measure off and mark on floor the exact dimensions of the case footprint. Snap chalk line for front and back position of base rail. Mark location of each joint front and back. Use a transit to find the highest point along both lines. Mark the difference, and place the appropriate number of shims required to maintain high-point level.

3

Image 3
Contents RHR-HEX, RHR2-HEX, RHR 1/2 HEX Ramona Avenue Chino, California 909 628-8942 FAX 800 Shipping DamageCut & Plan Views LevelingWiring Color Code Care and Cleaning Food HandlingControls Birdsall Staybright Cleaning InstructionsPlexiglass & Acrylic Care Wool Scouring Pads as these will mar the surfaceReplacing Overhead Heat Lamps RHR-HEX ~20 Rhrhex Standard60Hz 240V240 208 60zNit Case Shelf U Hex4 Rhr-hex 2 levelLoading 208V 240V L1 16.0 18.1 L2 13.1 14.6 L3 Ote Case M UST be grounded W6100003Modelwithshelfunit RHRHex5-6CaseWiringDiagram23.3 18.5 W6100004X4Squarecase Rhr SquareLoading 208V 240V 22.4 19.0 W6100005Wiring Schematics Design pending Contactor Hal Lamps Rhr 1/2 HexLoading 208V 240V 9.0 Ote Case M UST be grounded W6100007Hex Loading 208V 240V 14.8 16.5Grounded W6100008 561/2 CaseWi ringInstrument a stainless steel stem-type thermometer is Appendix A. Temperature GuidelinesAppendix C. Field Recommendations Allow the case to preheat for one hour prior to loadingScour or rub with a damp cloth Allen Stainless Steel PolishLimited Warranty Service Record
Related manuals
Manual 23 pages 2.05 Kb