hussman rhr-hex manual Replacing Overhead Heat Lamps

Page 7

Rev.9911

Maintenance

ALWAYS DISCONNECT ELECTRI- CAL POWER AT THE MAIN DIS- CONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT. This includes (but not limited to) Fans, Heaters, Thermostats, and Lights.

REPLACING OVERHEAD HEAT LAMPS

Overhead Halogen and Merco lamps are designed to last through many hours of use. Should there be a need to replace one, it is as simple as replacing a standard fluorescent light bulb.

The Heat lamps used in these cases get EXTREMELY HOT! NEVER touch a lamp until the case has had ample time to cool down! It is also highly recommended to handle lamps with gloves or use a cloth rag - not just for the heat factor, but also the oils in your fingers will drastically shorten the life of the lamp.

1.Turn light switch to OFF before replacing any lighting components.

2.Disconnect light fixture by removing power cord

from socket in the right rear interior corner of the merchandiser.

3.Place the shelf on a flat surface to remove the clear plastic protective shield from the fixture. Carefully insert one finger between the fixture socket and the protective shield. Use other hand to "pinch" lens cover (and simultaneously hold the fixture in place) while lifting with inserted finger.When shield separates from fixture at one end, remove it by SLOWLY pulling remainder of shield away from fixture.

4.Remove lamp by depressing spring loaded socket at end of fixture, and swinging opposite end of lamp from it's former position.

5.Using gloves or covering for lamp, insert new lamp into spring loaded socket, depressing socket until opposite end of lamp properly enters stationary light socket.

6.Return lamp to original position by lightly pinching it in from each side, and inserting shield flanges into fixture channel. Continue process along length of lamp shield until it is in it's final proper position.

7.Return lamp to original position by lightly pinching it in from each side, and inserting shield flanges into fixture channel. Continue process along length of lamp shield until it is in it's final proper position.

7

Image 7
Contents RHR-HEX, RHR2-HEX, RHR 1/2 HEX Ramona Avenue Chino, California 909 628-8942 FAX 800 Shipping DamageCut & Plan Views LevelingWiring Color Code Food Handling Care and CleaningControls Birdsall Staybright Cleaning InstructionsPlexiglass & Acrylic Care Wool Scouring Pads as these will mar the surfaceReplacing Overhead Heat Lamps RHR-HEX ~20 Rhrhex Standard60Hz 240V240 208 60zNit Case Shelf U Hex4 Rhr-hex 2 levelLoading 208V 240V L1 16.0 18.1 L2 13.1 14.6 L3 Ote Case M UST be grounded W6100003Modelwithshelfunit RHRHex5-6CaseWiringDiagram23.3 18.5 W6100004X4Squarecase Rhr SquareLoading 208V 240V 22.4 19.0 W6100005Wiring Schematics Design pending Contactor Hal Lamps Rhr 1/2 HexLoading 208V 240V 9.0 Ote Case M UST be grounded W6100007Hex Loading 208V 240V 14.8 16.5Grounded W6100008 561/2 CaseWi ringInstrument a stainless steel stem-type thermometer is Appendix A. Temperature GuidelinesAppendix C. Field Recommendations Allow the case to preheat for one hour prior to loadingScour or rub with a damp cloth Allen Stainless Steel PolishLimited Warranty Service Record
Related manuals
Manual 23 pages 2.05 Kb

rhr-hex specifications

The Hussman RHR-HEX is a cutting-edge refrigeration unit designed to meet the demands of modern retailers while focusing on energy efficiency, sustainability, and robust performance. This advanced refrigeration system has garnered attention due to its unique features and technologies that enhance both its functionality and ease of use.

One of the standout features of the RHR-HEX is its compact design which allows for flexibility in store layouts. The unit can be installed in various configurations, making it suitable for diverse retail environments, from supermarkets to convenience stores. Its modular design also simplifies maintenance, enabling quick access to components, which reduces downtime and operational disruptions.

The RHR-HEX employs state-of-the-art cooling technology that utilizes a high-efficiency compressor, which significantly lowers energy consumption. This efficiency is further supported by a smart control system that optimizes performance according to varying load conditions. The advanced thermal insulation used in the unit ensures minimal energy loss, contributing to lower operational costs.

Additionally, the Hussman RHR-HEX incorporates integrated LED lighting which not only enhances product visibility but also consumes less power compared to traditional lighting solutions. This feature aligns with the growing emphasis on sustainability in retail practices, further reducing the carbon footprint of the store.

One of the key characteristics of the RHR-HEX is its ability to operate in high ambient temperatures, making it a reliable choice for warmer climates. Its robust design ensures consistent performance, even under challenging conditions, thus maintaining the integrity of stored products, especially perishables.

Furthermore, the unit supports eco-friendly refrigerants, in line with global environmental standards. By adopting refrigerants with a lower global warming potential, Hussman demonstrates its commitment to sustainable practices that comply with regulations and promote a healthier planet.

In conclusion, the Hussman RHR-HEX is a solution that embodies efficiency, versatility, and sustainability in refrigeration. Its advanced features, combined with innovative technologies, make it an ideal choice for retailers looking to enhance operational efficiency while supporting environmentally friendly practices. With the RHR-HEX, retailers not only achieve their cooling needs but also contribute to a more sustainable future.