Parts of Indoor Unit

 

 

 

 

 

 

 

 

Fasten the unit(s) on the

 

 

 

 

 

 

 

Distance between the

upper hook of wall plate

 

No.

 

Part

 

Qty

 

 

Clearance in front of unit(s)

unit(s) and ceiling should

Distance between

 

 

 

 

 

 

 

 

 

should be no less than 10’

be more than 2”

 

 

 

 

 

 

 

 

 

 

 

 

1

Remote Control

 

 

1/unit

 

 

 

 

 

 

 

the unit(s) and the wall

 

 

 

 

 

 

 

 

 

should be more than 6”

 

 

 

 

 

 

 

 

Distance between the

 

 

 

Wall plate

 

 

Remote Control

 

 

 

 

unit(s) and the wall should

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Fixture

 

1/unit

 

be more than 6”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Batteries 'LR03'

 

 

2/unit

 

 

 

 

 

 

 

 

Patch

 

(AAA)

 

 

 

 

Fasten the unit(s)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on the lower hook

 

 

 

 

 

 

4

Manual

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

of wall plate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outgoing tubing

 

Wall cap

 

 

 

 

Parts of Outdoor Unit

 

 

 

 

(bottom)

Connecting wire

Through the wall

 

 

 

 

 

 

 

 

No.

 

Part

 

Qty

 

 

 

 

 

 

tubing (O.D. 2.36”)

 

 

 

 

 

 

 

 

 

 

(22.72”) 9/12 Btuh

 

 

 

 

 

 

 

9/12 Btuh

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

4

 

 

 

(23.94”) 18/24 Btuh

 

NOTE: Always check superheat

 

 

 

 

 

 

 

(8.86”)9 Btuh 12(11.02”)Btuh 18/24(14.25”)Btuh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and subcooling of system.

 

 

 

Rubber Cushion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Height limit: below 25ft.

 

 

18/24 Btuh

 

 

 

 

 

 

 

 

2

 

 

4

 

 

 

 

• Maximum tubing length: below 50ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rubber Cushion

 

 

 

 

 

 

 

 

Tubing length over 25ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9/12 Btuh (Single or Multi-Zone)

 

3

Drain Pipe

 

1

 

 

Outdoor unit mounting

 

• Charge additional refrigerant amount,

 

 

 

 

 

 

 

 

 

 

leg dimension

 

additional refrigerant amount =0.22oz./ft.>25’.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18/24 Btuh (Single Zone Only)

 

 

 

 

 

 

 

 

 

 

 

 

• Charge additional refrigerant amount,

 

 

 

! CAUTION !

 

 

 

 

 

More than 12”

 

 

 

 

 

 

 

 

additional refrigerant amount =0.44oz./ft.>25’.

 

• Read this installation manual thoroughly before installing

 

 

 

 

 

 

 

• Capacity drops slightly.

 

the air conditioner(s) for proper installation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

More than 4”

 

• All field wiring must be installed by a licensed electrician

 

More than 2”

 

 

 

 

 

 

 

 

 

 

 

and must comply with all national and local codes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• All field piping must be installed by a licensed refrigeration

 

 

 

 

 

 

 

 

technician and must comply with all national and local

 

 

 

 

 

 

 

 

codes.

 

 

 

 

 

 

 

 

 

 

 

• Never plug unit(s) into an electrical outlet.

 

 

 

 

 

 

 

 

 

• Do not touch compressor, pipes and valves without pro-

 

 

 

 

 

More than 10”

 

tective gloves during and after operation, because these

 

 

 

 

 

 

 

 

parts may become hot (more than 100°C (212°F).

 

More than 16”

 

 

 

 

 

 

• Explain the operating procedure of the air conditioner to

 

 

 

 

 

 

 

 

the customer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DETERMINATION OF INSTALLING POSITION

Install the Air Conditioner(s) by taking into account

the following points, upon the customer’s consent.

! CAUTION !

Make sure that the indoor unit(s) are installed high enough, over 6 feet, (beyond reach of young children).

Be sure chosen location can properly support the weight of the unit(s) and will provide adequate damping of vibration and noise.

Indoor Unit

Do not install the unit(s) near a heat source.

Be sure that air outlet and inlet are not obstructed.

Be sure all clearances are as specified in the above figure (front, upper, left and right of the unit(s)).

Allow convenient drainage and piping connection with the out- door unit.

Avoid installing the unit(s) in direct sunlight.

Install the unit(s) on walls that can support their weight.

Outdoor Unit

Insure chosen location can provide adequate drainage and good ventilation.

Do not install in an area with flammable or corrosive vapors. Avoid salty air or sulfuric gas areas.

Be sure all clearances are specified in the above figure (front, upper, left, right and rear of the unit) and also open on more than two sides.

Be sure hot exhaust and noise does not bother the customer or their neighbors.

Do not allow hot exhaust to blow directly on pets and plants.

ECR International

11

Hyundai Ductless Split System

Image 11
Contents Installation Manual and Operating Instructions Melody Buzzer Safety Tips for OperationFeatures Deodorizing FunctionComponents and Functions Current Time Entry Part Name of Remote Control and KEY FunctionInstalling Batteries Installing Remote Preparation Before OperationManual Operation DRY ModeOperation Auto Operation„ Heating Capability Circulation Mode„ Features of Heating Operation FAN SPEED, AIR Flow DirectionHigh Power Mode Timer Mode ON, OFFHigh Power Mode To Cancel Press the C buttonEmergency Operation Sleep Mode1HR Timer Mode Sleep ModeBefore Calling for Service MaintenancePlease Check the Following Before Calling for ServiceCall for Service Trouble Check by SELF-TEST ModeDetermination of Installing Position See Fig Mounting of the Installation PlateAir Purge and Charging Installing of the Outdoor UnitLeak Test DrainageCool Model Connecting the CableConnecting of Power Source Cool and Heat ModelCable Connection 9/12 Btuh Single or Multi-Zone Test RUNCable Connection 18/24 Btuh Single Zone Only Electrical Specifications and System PerformanceCompletion of Interconnecting Tubing HCW18000 HCW24000 HHW18000 Operating Characteristics Single Zone CoolingHCW9000 HCW12000 HHW12000HHW12000 HHW18000 HHW24000 Operating Characteristics Single Zone HeatingHMCW24000 HMHW24000 Operating Characteristics Multi-ZoneThermister Character Diagrams HMCW18000 HMHW18000

HACM09DB - HCCM99DB, HACW24DB - HCCW24DB, HAHW24DB - HCHW24DB, HACW18DB - HCCW18DB, HAHM09DB - HCHM99DB specifications

The Hyundai HAHW12DB, HCHW12DB, HACW18DB, HCCW18DB, HAHW24DB, HCHW24DB, HACM09DB, HCCM99DB, HAHW18DB, and HCHW18DB are advanced air conditioning units that cater to residential and commercial cooling needs with cutting-edge features and technologies.

These models are designed for efficiency and ease of use, contributing to a comfortable indoor environment. One of the standout features of these units is their high energy efficiency ratio, which translates to lower electricity bills while maintaining optimal cooling performance. Many models are equipped with inverter technology that modulates the compressor speed based on demand, ensuring consistent indoor temperatures without excessive energy consumption.

Another key characteristic of the Hyundai air conditioning units is their multi-functional capabilities, offering not just cooling but also heating and dehumidification modes. This versatility makes them suitable for year-round use, adapting seamlessly to changing weather conditions. The units also incorporate advanced filters designed to enhance indoor air quality by trapping allergens, dust, and other pollutants, contributing to a healthier living environment.

User-friendliness is another aspect of the Hyundai HAHW and HACM series. Each model often includes a user-friendly remote control, allowing for convenient adjustments from anywhere in the room. Additionally, the digital display makes monitoring the temperature and settings straightforward. Many models also feature programmable timers, enabling users to set the unit to operate only when needed, which further increases energy efficiency.

In terms of design, Hyundai prioritizes aesthetics, ensuring that their air conditioning units can seamlessly fit into various interior styles. Compact and sleek, these models take up minimal space while providing powerful cooling capabilities.

The durability of the Hyundai units is bolstered by high-quality materials and construction techniques, ensuring they can withstand even the harshest operating conditions. Moreover, the brand typically offers a robust warranty for these models, highlighting their commitment to quality and customer satisfaction.

Overall, the Hyundai HAHW12DB, HCHW12DB, HACW18DB, HCCW18DB, HAHW24DB, HCHW24DB, HACM09DB, HCCM99DB, HAHW18DB, and HCHW18DB are ideal choices for anyone looking for reliable, energy-efficient, and versatile air conditioning solutions. With a focus on innovative technology and user-centric features, they provide comfort and convenience for any indoor environment.