HomeTech PMS03 Changing the House and Unit Codes, Motion Detection only after Dusk or 24 hours

Page 2

Outdoor Motion Detector

PMS03

 

 

Changing the House and Unit Codes:

1.Press and hold the House Code button, the Red LED flashes first, goes off and then blinks the current setting.

2.Release and press the desired number of times for the House Code that you want (once for A, twice for B, etc.).

3.Hold the House Code button on the last press; after 3 seconds the Red LED will blink the amount of times to confirm your settings.

Note: For Unit Code changes, perform the same as above but using the Unit Code button.

Motion Detection only after Dusk or 24 hours:

This section configures the PMS03 to send the ON Command at dusk (no light) and the OFF Command at dawn (any light) for the Unit Code one number higher than the current Unit Code setting (i.e., PMS03 set to A1 will control A2 when dawn/dusk is detected). When battery power is initially applied to the PMS03, this feature is disabled. This section also configures the PMS03 to detect motion at all times or only at night. The default setting is to detect motion at all times.

1.Press the UNIT/OFF button once.

2.The red LED flashes.

3.Press and hold the HOUSE/ON button.

4.The green LED (located behind the sensor window) turns on.

5.A few seconds later, the PMS03 reports its current setting. Release the button. The number of blinks reported by the PMS03 represent the following:

Blinks

Dawn/Dusk

Motion Detection

1

Disabled

Day & Night

2

Disabled

Night Only

3

Enabled

Day & Night

4

Enabled

Night Only

6.If you do not wish to change the current setting, take no further action at this point. A few seconds later, the PMS03 will timeout. The PMS03 will indicate this to you by displaying a sustained blink (slightly longer than the report blinks).

7.To change the current setting, first select the Dawn/Dusk and Motion Detection settings you wish to use from the chart above and remember the blink value listed to the left of them (i.e. for dawn/dusk detection enabled and detect motion only at night there are 4 blinks). Determine the setting you wish to use before starting the programming procedure because the PMS03 will only wait a few seconds after it has finished reporting its current setting for you to begin entering the new setting.

8.Press the HOUSE/ON button the number of times equal to the blink value in the chart above. Hold the button down on the last press (i.e. for a setting of dawn/dusk detection enabled and detect motion only at night, press the HOUSE/ON button 4 times and hold on the last press).

9.A few seconds later, the red LED will blink the new setting.

10.If the programming fails, the red LED will display a sustained blink (slightly longer than the report blinks). This can occur if you wait too long to start your programming, you press the button more than 2 times, or you press the UNIT/OFF button. If the programming procedure fails, you must start the procedure over.

Delay after Motion before an OFF command is sent:

When no motion is detected, the default amount of time that will pass before the OFF Command is transmitted is Analog; i.e., the setting on the Top Dial (under the rubber plug on the top of the PMS03). The dial adjusts the delay range from 1 minute to 60 minutes. The following procedure allows you to alter this setting.

1.Press the House button once, the Red LED flashes.

2.Press and hold the Unit button, the Green LED turns ON. 3 seconds later, the Red LED will report the setting as follows:

-1 blink for Analog Dial 1-60 Mins. -6 blinks for 32 minutes.

-2 blinks for 2 minutes.

-7 blinks for 64 minutes.

-3 blinks for 4 minutes.

-8 blinks for 128 minutes.

-4 blinks for 8 minutes.

-9 blinks for 256 minutes.

-5 blinks for 16 minutes.

Note: When the setting is 2 blinks or higher, the dial on top of the PMS03 is disabled.

3.If you do not wish to change the current setting, take no further action at this point. A few seconds later, the PMS03 will timeout. The PMS03 will indicate this to you by displaying a sustained blink (slightly longer than the report blinks).

4.To change the current setting, first select the delay time you wish to use from the chart above and remember the blink value listed to the left of it (i.e. for 64 minutes there are 7 blinks). Determine the time you wish to use before starting the programming procedure because the PMS03 will only wait a few seconds after it has finished reporting its current setting for you to begin entering the new setting.

5.Press the UNIT/OFF button the number of times equal to the blink value in the chart above. Hold the button down on the last press (i.e. for a setting of 64 minutes, press the UNIT/OFF button 7 times and hold on the last press).

6.A few seconds later, the red LED will blink the new setting.

7.If the programming fails, the red LED will display a sustained blink (slightly longer than the report blinks). This can occur if you wait too long to start your programming, you press the button more than 2 times, or you press the HOUSE/ON button. If the programming procedure fails, you must start the procedure over.

Sensor Detection vs. Direction of Motion

For best detection results, mount the PMS03 so the person entering the area will cut across the PMS03's field of view. Do not mount the PMS03 near hot or cold sources (i.e. heat vents, air conditioners, direct or reflected sunlight) as this may cause false triggering of the PMS03. Sensor's fields of view are 90 Degrees Horizontally, 30 Degrees Vertically and detection range is approximately 20Ft.

DEFAULTS:

After replacing batteries, please wait 30 seconds before the PMS03 will see any motion. After transmission, you need to wait 10 seconds before the PMS03 will see motion again. The default House & Unit Codes for Motion Detection is: "A1" ON.

The default for Motion Detection is: detect at all times (24 HOUR).

The default for Time Out, that "A1" OFF is sent is: 1 minute.

The default House/Unit Codes for Dusk/Dawn, is: "A2" ON at Dusk, "A2" OFF at Dawn.

Note: As with all RF transmitter devices; electrical fields, metal doors or door window frames and appliances can cause interference that can decrease the strength of the transmitted signal. Re-locating the PAT01 RF Base Transceiver may increase your ability to receive the necessary X10 Signals from the PMS03.

 

PMS03_03_03/07

Tampa, FL 33542

Technical Support: (800) 832-4003

 

Image 2
Contents Buttons in Battery LED Motion Indicator Code Indicator Manual Off delayCommand Indicator After motion Green LED Electrical Protocol InstallationMotion Detection only after Dusk or 24 hours Delay after Motion before an OFF command is sentChanging the House and Unit Codes Blinks Dawn/Dusk Motion Detection

PMS03 specifications

The HomeTech PMS03 is a modern powerhouse designed for smart home enthusiasts and those looking to enhance their living experience with technology. This cutting-edge product seamlessly integrates into any home environment, providing enhanced functionality, usability, and comfort.

One of the main features of the HomeTech PMS03 is its advanced automation capabilities. With its intuitive smart scheduling system, users can set routines for their appliances, lighting, and climate control, allowing for a personalized living experience. This automation not only saves time but also enhances energy efficiency, as devices can be programmed to operate during off-peak hours, reducing electricity costs.

The PMS03 is equipped with state-of-the-art connectivity options, including Wi-Fi, Bluetooth, and Zigbee protocols. These connectivity features ensure that users can manage their devices remotely through a smartphone app or voice commands via popular digital assistants like Amazon Alexa or Google Assistant. This versatility allows for real-time control over home settings, ensuring that users can adjust their environment with ease and convenience.

In terms of design, the HomeTech PMS03 boasts a sleek, modern aesthetic that fits seamlessly into any décor. Its compact size allows for flexible placement throughout the home, whether on a countertop, shelf, or wall-mounted. The user-friendly interface features a responsive touchscreen display, making navigation simple and efficient.

Security is also a priority in the PMS03 model. With built-in encryption protocols and secure access controls, users can rest assured that their data and privacy are protected. Additionally, the PMS03 provides real-time monitoring and alerts for any unusual activity within the connected ecosystem, adding an extra layer of security for peace of mind.

Compatibility is a key characteristic of the HomeTech PMS03. It is designed to work with a wide range of smart home devices and appliances from various manufacturers, ensuring that users can create a cohesive and interconnected smart home environment without being limited to a specific brand.

In summary, the HomeTech PMS03 stands out with its advanced automation features, robust connectivity options, stylish design, strong security measures, and broad compatibility. This innovative home management system empowers users to create a smart living space tailored to their individual needs, making everyday tasks more effortless and enjoyable. With the PMS03, the future of smart living is at your fingertips.