Hisense Group KFR 2601GW/BPE Using the 12-Hour on and OFF Timer, Setting Procedures

Page 15

Using the 12-Hour ON and OFF Timer

1.TIMER ON mode (Example)

After the length of timer set for TIMER ON elapses, the unit begins operating.

The display depicted at left lindicates that the air conditioner will begin operating in three hours.

Setting Procedures:

C

HOUR

ON

1HR ON/OFF TEMP

HIGH

POWER

FLAPMODE

STEP 1

ON

OFF

FAN

SPEED

 

 

STEP 2

SET CLR SOFT SLEEP

STEP 1

Press the MODE button and set the desired operation mode and

 

press the ON/OFF operation button.

 

 

 

STEP 2

Press the timer ON button to

set the

time at which you want

 

operation to begin. The time can be set for one to twelve hours,

 

in one hour steps.

 

 

 

 

 

 

1

2

3....... 12

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 3

Press the timer SET button (which advances the time displayed).

 

 

 

 

 

 

 

STEP 3

 

 

 

¡ñ The display changes immediately to its status previous to

timer

setting, but the

BATTERY

 

 

 

A/C SENSOR

ACL

 

 

 

 

 

 

 

 

 

¡±indication remains.

 

 

 

 

 

 

 

¡°

ON

 

 

 

 

 

 

 

¡ñ To check the status of the timer while it is counting down,

press

the timer SET

 

 

 

 

 

button .

 

 

 

 

 

 

 

Cancellation procedures: press the CANCEL button once again.

 

 

 

 

 

 

 

 

 

 

 

1.TIMER OFF mode

After the length of timer set for TIMER OFF elapses, the unit stops operating.

 

 

(Example)

 

 

The display depicted at left lindicates that the air conditioner will stop operating in

 

 

 

 

 

 

 

 

 

 

five hours.

 

 

 

 

 

 

 

Setting Procedures:

 

 

 

 

 

 

 

C

 

 

 

 

HOUR

OFF

1HR ON/OFF TEMP

HIGH

POWER

FLAPMODE

ON

OFF

FAN

SPEED

 

 

STEP 1

SET CLR SOFT SLEEP

STEP 2

BATTERY

A/C SENSOR

ACL

 

STEP 1 Press the OFF button and set the time at which you want

operation to stop.

 

 

 

 

The time can be set for one to

twelve

hours, in one hour steps.

 

1

2

3....... 12

 

 

 

 

 

 

 

 

 

 

 

STEP 2 Press the timer SET button (which advances the time displayed).

¡ñ The display changes immediately to its status previous to timer setting, but the ¡°OFF ¡±indication remains.

¡ñ To check the status of the timer while it is counting down, press the timer SET button .

Cancellation procedures: press the CANCEL button once again.

13

Image 15
Contents KFR 2601GW/BPE KFR 2801GW/BPE Compact Size Alert Symbols ContentsPage Composition of the Air Conditioner ON/OFF button Hipower lampPower lamp Timer lampSymbols ON/OFF button Transmitter HR. Timer button High Power buttonTimer ON/OFF button DisplayMode selector button Timer on buttonTimer OFF button Timer SET/CANCEL buttonOperation Guide HOW to Install BatteriesOperation with the Remote control Unit Low Adjusting the Fan SpeedAutomatic MediumHorizontal Adjusting the Airflow DirectionNight Setback / Simultaneous Use Energy Saving ¡ñNight Setback ModeSetting Procedures Using the 12-Hour on and OFF TimerUsing the 1-Hour OFF Timer High Power OperationCancellation procedures Special Remarks Heating Operation Heating performance Defrosting Power LampOperation without the Remote Contorol Unit Care and CleaningCare and Cleaning Tips for Energy Saving TroubleshootingKFR-2601GW/BPE KFR-2801GW/BPE Schematic DiagramControl Board

KFR 2601GW/BPE, KFR 2801GW/BPE specifications

Hisense Group has been a prominent player in the global air conditioning market, known for delivering innovative solutions that prioritize energy efficiency, user comfort, and advanced technology. Among their notable products, the KFR 2801GW/BPE and KFR 2601GW/BPE stand out for their impressive performance and cutting-edge features.

The KFR 2801GW/BPE is engineered for larger spaces, offering a cooling capacity of 28000 BTU, making it ideal for homes, offices, and commercial settings. It is equipped with inverter technology, which allows for optimal energy consumption while maintaining consistent temperatures. This technology not only reduces power consumption but also minimizes noise levels, creating a comfortable indoor environment. The unit features a 3D airflow system that ensures even distribution of cool air across the room, eliminating hot spots and ensuring every corner receives adequate cooling.

In contrast, the KFR 2601GW/BPE is designed for smaller spaces, providing a cooling capacity of 26000 BTU. Like its larger counterpart, it incorporates inverter technology for enhanced energy efficiency. The KFR 2601GW/BPE is also equipped with multi-speed fans that allow users to customize airflow according to their preferences. Its user-friendly remote control provides effortless operation, also allowing users to set timers and adjust settings conveniently.

Both models boast advanced air purification features. They come with multi-layer filters that effectively capture dust, allergens, and other particles, improving indoor air quality. This is particularly beneficial for individuals with respiratory issues or allergies, providing a healthier living environment. The units are also designed with a sleek, modern aesthetic that complements any interior decor.

Additionally, Hisense has integrated smart technology into both models, allowing users to control their air conditioning units via mobile apps. This feature enables remote access, scheduling, and energy monitoring, providing convenience and contributing to energy savings.

In summary, the Hisense KFR 2801GW/BPE and KFR 2601GW/BPE air conditioning units exemplify the brand's commitment to quality, efficiency, and user-centric design. With their inverter technology, air purification capabilities, and smart features, these models provide effective cooling solutions tailored to a variety of settings, making them ideal choices for consumers seeking reliable and innovative air conditioning options.