Hisense Group KF 346GWE instruction manual Adjusting the Fan Speed

Page 12

Adjusting the Fan Speed

A. Automatic

 

Simply set the FAN SPEED selector to the AUTO position.

 

A microcomputer in the air conditioner automatically controls the fan speed when the AUTO

mode is selected. When the air

co nditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is detected by the microcomputer which then automatically switches the fan speed to the most suitable level.

Cooling mode:

When difference between room temperatureand set

FAN SPEED

temperature is

 

RT T+3

High

 

 

T+3℃ > RT T+1

Medium

 

 

RTT+1

Low

 

 

Mild drying mode:

 

When difference between room temperature

FAN SPEED

and set temperature is

 

RT T+5

High

 

T+5℃> RT T+3

Medium

RtT+3

Low

NOTE

The above table assumes that the sensor on the remote control is being used. If the sensor in the indoor unit is

being used (the indicator is on), actual operation may differ slightly from the operation described in table.

B. Manual

If you want to adjust fan speed manually during operation, just set the FAN SPEED selector

as desired.[ (High), (Medium), or (Low)]

10

Image 12
Contents KF 346GWE Simple One-touch Wireless Remote Control Hour on or OFF TimerHour OFF Timer Automatic Restart Function for Power FailureContents Alert SymbolsPage Composition of the Air Conditioner Hipower lamp Power lampTimer lamp ON/OFF buttonSymbols Transmitter HR. Timer button High Power button Timer ON/OFF buttonDisplay ON/OFF buttonTimer on button Timer OFF buttonTimer SET/CANCEL button Mode selector buttonHOW to Install Batteries Operation GuideOperation with the Remote Control Unit Adjusting the Fan Speed Adjusting the Airflow Direction HorizontalVertical Sweep functionNight Setback Mode Night Setback / Simultaneous Use Energy SavingUsing the 12-Hour on and OFF Timer Setting ProceduresSetting Procedure Using the 1-Hour OFF Timer High Power OperationCancellation procedure Cancellation proceduresSpecial Remarks Care and Cleaning Operation without the Remote Control UnitCare and Cleaning Troubleshooting Tips for Energy SavingTrouble Possible Cause Remedy Schematic Diagram KF-346GWE KF-256GWEElectric Wiring Diagram Outdoor Packing List