Generac Power Systems OG 2697 manual Generator Installation, Before Installation, Nfpa Standards

Page 3

This exhaust system must be installed properly, in strict compliance with applicable codes and standards.

Keep hands, feet, clothing, etc., away from drive belts, fans and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating.

Adequate, unobstructed flow of cooling and ventilating air is critical to prevent buildup of explosive gases and to ensure correct generator operation. Do not alter the installation or permit even partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator.

Keep the area around the generator clean and uncluttered. Remove any materials that could become hazardous.

When working on this equipment, remain alert at all times. Never work on the equipment when physically or mentally fatigued.

Generator Installation

These generators are air-cooled, engine- driven generator sets designed to supply electric power that operates critical electrical loads during utility power failure. Your generator was factory-installed in a weather resistant, all metal enclosure and are intended for outdoor installation only.

Before Installation

The generator’s rated wattage/amperage capacity must be adequate to handle all electrical loads that the unit will power. The critical (essential) loads may need to be grouped together and wired into a separate “emergency” distribution panel.

Connecting this generator to an electrical system, normally supplied by an electric utility, shall be by means of a transfer switch,

to isolate the electrical system from the utility distribution system when the generator is operating. Failure to isolate the electrical system by these means will result in damage to the generator and may also result in injury or death to utility workers due to backfeed of electric energy.

If an open bottom is used, the engine-generator is to be installed over non-combustible materials and should be located such that combustible materials are not capable of accumulating under the generator set.

Only qualified, competent installation contractors or electricians thoroughly familiar with applicable codes, standards and regulations should install this standby electric power system. The installation must comply strictly with all codes, standards and regulations pertaining to the installation.

After the system has been installed, do nothing that might render the installation in non-compliance with such codes, standards and regulations.

NFPA Standards

The following published standards booklets pertaining to standby electrical systems are available from the National Fire Protection Association (NFPA), Batterymarch Park, Quincy, MA 02269:

NFPA 37, STATIONARY COMBUSTION ENGINES AND GAS TURBINES

NFPA 54, NATIONAL FUEL GAS CODE

NFPA 58, LIQUIFIED PETROLEUM GAS CODE

NFPA 70, NATIONAL ELECTRIC CODE (NEC)

NFPA 99, STANDARD FOR HEALTH CARE FACILITIES



Image 3
Contents Installation Guidelines General Hazards Generator Installation Before InstallationNfpa Standards Battery Installation Other Published StandardsGrounding the Generator Vented Batteries Before You Begin Site Preparation & Generator PlacementPage Converting To LP Vapor Installing & Connecting Gas Lines Page External Electrical Connections Installing The Automatic Transfer Switch When three-conductor wiring is used, two Operational Tests Page Page Page Setting The Automatic Exercise Function Page Generac Power Systems, Inc. All rights reserved

OG 2697 specifications

Generac Power Systems OG 2697 is a robust and reliable generator designed to provide seamless power solutions for various applications, ranging from residential use to small commercial operations. Known for its durability and efficiency, the OG 2697 stands out in the competitive generator market, making it a preferred choice for many users seeking dependable energy solutions.

One of the main features of the OG 2697 is its dependable power output. With a substantial wattage capacity, this generator is capable of handling multiple appliances and devices simultaneously. Whether it's powering essential household equipment during an outage or supplying energy for outdoor events, the OG 2697 delivers consistent performance.

The generator is equipped with advanced technologies to optimize its operation. It incorporates a powerful, highly efficient engine that ensures high fuel efficiency while minimizing emissions. This not only contributes to lower operational costs but also aligns with contemporary environmental standards. The OG 2697 boasts a user-friendly control panel, providing easy access to vital information such as fuel levels and operational status. This intuitive interface simplifies the operation process, making it accessible even for those with limited technical knowledge.

Another noteworthy characteristic is its portability. The OG 2697 is designed with mobility in mind, featuring a compact and lightweight structure that allows for effortless transport. This is especially beneficial for users who need to move the generator for various applications, from backyard parties to job sites.

Durability is a hallmark of the Generac brand, and the OG 2697 is no exception. Its rugged construction ensures it can withstand the rigors of outdoor use. Additionally, the generator is equipped with built-in safety features, such as automatic shutoff systems and overload protection, which enhance its reliability and ensure safe operation.

In conclusion, Generac Power Systems OG 2697 offers a winning combination of power, efficiency, portability, and durability. With its innovative features and user-centric design, this generator is well-suited for a wide range of applications, ensuring users have the reliable power they need when it matters most. Whether for home backup or outdoor activities, the OG 2697 continues to be a top choice for those seeking dependable energy solutions.