Electrolux CF921BS00, CF921ORB00 Trouble Shooting, Trouble Probable Cause Suggested Remedy

Page 15

Trouble Shooting

! WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.

TROUBLE

 

PROBABLE CAUSE

 

SUGGESTED REMEDY

1. Fan will not start.

1.

Fuse or circuit breaker blown.

1.

Check main and branch circuit fuses or circuit

 

 

 

 

breakers.

 

2.

Loose power line connections to the fan,

2.

Check line wire connections to fan and switch

 

 

or loose switch wire connections in the

 

wire connections in the switch housing.

 

 

switch housing.

!

WARNING: Make sure main power is

 

 

 

 

turned OFF.

 

3.

Dead battery in remote control transmitter.

3.

Replace battery (red indicator light on transmitter

 

 

 

 

should light when any button is pressed).

 

4.

Code switches in remote control receiver

4.

Check that code switches are in same positions.

 

 

and transmitter are not in same positions.

 

Reset if necessary.

 

 

 

 

 

2. Fan sounds noisy.

1.

Blades not attached to fan.

1.

Attach blades to fan before operating.

 

2.

Loose screws in motor housing.

2.

Check to make sure all screws in motor housing

 

 

 

 

are snug (not over-tight).

 

3.

Screws securing fan blade flanges to

3.

Check to make sure the screws which attach

 

 

motor hub are loose.

 

the fan flanges to the motor hub are tight.

 

4.

Wire connectors inside switch housing

4.

Check to make sure wire connectors in switch

 

 

rattling.

 

housing are not rattling against each other or

 

 

 

 

against the interior wall of the switch housing.

 

 

 

!

WARNING: Make sure main power is

 

 

 

 

turned OFF.

 

5.

Screws holding blades to flanges

5.

Tighten screws securely.

 

 

are loose.

 

 

 

 

 

 

 

3. Fan wobbles

1.

Setscrew in motor coupling is loose.

1.

Tighten both setscrews securely in the motor

excessively.

 

 

 

coupling.

 

2.

Setscrew in hanger ball/downrod

2.

Tighten the setscrew in the hanger ball/

 

 

assembly is loose.

 

downrod assembly.

 

3.

Screws securing fan blade flanges to

3.

Check to be sure screws which attach the fan

 

 

motor are loose.

 

blade flanges to the motor are tight.

 

4.

Fan blade flanges not seated properly.

4.

Check to be sure the fan blade flanges seat

 

 

 

 

firmly and uniformly to the surface of the motor.

 

 

 

 

If flanges are seated incorrectly, loosen the

 

 

 

 

flange screws and retighten according to the

 

 

 

 

procedure in the section on "How to Put

 

 

 

 

Your Ceiling Fan Together".

 

5.

Hanger bracket and/or ceiling outlet

5.

Tighten the hanger bracket screws to the outlet

 

 

box is not securely fastened.

 

box, and/or secure outlet box.

 

6.

Fan blades out of balance.

6.

Interchanging an adjacent (side-by-side) blade

 

 

 

 

pair can redistribute the weight and result in

 

 

 

 

smoother operation.

 

 

 

 

 

15

ETL Model No.: CF921

Image 15
Contents Avant ECO Safety Instructions Emerson Quick Start Guide Wiring Ceiling Fan Materials Unpacking InstructionsElectrical Requirements How to Put Your Ceiling Fan TogetherPIN Hanger Ball Ceiling Cover Coupling Cover Switch How to Hang Your Ceiling Fan How to Wire Your Ceiling Fan Setting Operating Frequency of Remote Control Installation of Remote Control BatteryHigh Speed Conditioning of Fan Control Operation of Your Remote ControlOptional Accent Kit Installation Accessories MaintenanceTrouble Probable Cause Suggested Remedy Trouble ShootingRepair Parts Key Model Numbers Description Repair Parts ListingETL Model No. CF921 ETL Model No. CF921 Limited Warranty