To set Local Sense function:

1.Slide down front cover of controller below ON/OFF button. See Fig. 4.

2.Press the SENSE button. The “House” symbol will ap- pear on the display screen. See Fig. 12.

3.Place the remote control in desired location in room. Be sure there is a direct line between the remote control and the unit.

To Cancel Local Sense function — While in “Local Sense” function, press the SENSE button. The “House” symbol will disappear from the display screen and Local Sense function will be canceled.

Fig. 10 — Room Air Temperature Indicator on

Remote Control Display

DELAYED START/STOP — This function will delay the Start/Stop function in increments of 1 hour. Delayed Start/Stop can be programmed with the unit turned ON or OFF.

With the unit turned ON:

1.Slide down front cover of controller below ON/OFF button. See Fig. 4.

2.Press the DELAY button. The clock will advance 1 hour and the word “STOP” and number “3” will flash. See Fig. 11.

3.Press the DELAY button once to advance the clock an ad- ditional hour until desired delayed time is reached. Be sure to point the remote control toward the unit while pressing the DELAY button.

4.The word “STOP” will stop flashing when the command has been transmitted and received by the unit.

With the unit turned OFF:

1.Slide down front cover of controller below ON/OFF button. See Fig. 4.

2.Press the DELAY button. The clock will advance 1 hour and the word “START” and number “3” will flash. See Fig. 11.

3.Press the DELAY button once to advance the clock an ad- ditional hour until desired delayed time is reached. Be sure to point the remote control toward the unit while pressing the DELAY button.

4.The word “START” will stop flashing when the com- mand has been transmitted and received by the unit.

Canceling Delayed Start/Stop — To cancel the Delayed Start/ Stop function, follow the instructions in Canceling Specific Start/Stop Time Period section.

NOTE: The Delay setting is stored in Time period 3.

LOCAL SENSE FUNCTION (2-Way Remote Control) — The local sense function allows the remote control to operate by transmitting the room air temperature to the unit at regular intervals from wherever the controller is located in the room. The unit will then operate to make the air near the remote con- trol reach the desired temperature.

S T O P

3

D A I LY

PROGRAMMING DISPLAY WITH UNIT ON

S TA R T

3

D A I LY

PROGRAMMING DISPLAY WITH UNIT OFF

Fig. 11 — Delayed Start/Stop Indicators on

Remote Control Display

 

 

 

 

LOCAL

 

 

 

 

SENSE

 

 

 

 

INDICATOR

MODE

FAN

SWEEP

II I I

 

 

 

I

II

 

 

II

 

I

 

 

I

 

I

 

 

I

 

I

 

 

II II

 

 

 

A

A

 

Fig. 12 — Local Sense Indicator on Remote

Control Display

6

Image 6
Contents Contents Introduction General Setting Clock OperationLocation of Clock Set Button On Remote Control Timer Display Set Up on Remote Control Daily Timer Indicator on Remote Control Display Cleaning and Maintenance Feature DescriptionRemoving Air Filters Troubleshooting Guide Problem Possible Cause SolutionDealer’s Name Address Page Copyright 2002 Carrier Corporation