Installation of Indoor Unit

Wiring Connection:

(1) Remove the cord clamp.

(2) Process the end of the connection cords to the dimensions shown in Fig.19.

(3) Connect the end of the connection cord fully into theterminal block.

(4)Fasten the connection cord with a cord clamp.

(5)Fasten the end of the connection cord with the screw.

(6)The power cable and connecting cable are self-provided.

(7)L,N and 1,2 are equal on the terminal block.

Note:Connect the black terminal of indoor unit with the black terminal of outdoor unit pro- perly using the connecting wire which has both white terminals in the accesory bag, and connect the blue terminal of indoor unit with the white terminal of out terminal as the same(For heat pump model).For cooling only unit,just connect the black terminal

of indoor unit with the black terminal of outdoor unit properly.

Fig. 19

INDOOR UNIT

TERMINIAL BLOCK

Y/G

R S T N

1

2

3

 

W

B

R

Y/G

1 2 3

INDOOR UNIT

L N 3 4 5

TERMINIAL BLOCK

R S T N

L N 3 4 5

 

 

 

 

OUTDOOR UNIT

POWER SUPPLY:

TERMINIAL BLOCK

3N~,380-400V,50Hz

 

3N~,380-400V,50Hz

OUTDOOR UNIT

TERMINIAL BLOCK

HCFU-42CF03

HCFU-42HF03

WARNING

(1)Always use a special branch circuit and install a special receptacle to supply power to the room air conditioner.

(2)Use a circuit breaker and receptacle matched to the capacity of the room air conditioner.

(3)The circuit breaker is installed in the permanent wiring. Always use a circuit that can trip all the poles of the wiring and has an isolation distance of at least 3mm between the contacts of each pole.

(4)Perform wiring work in accordance with standards so that the room air conditioner can be operated safely and positively.

(5)Install a leakage circuit breaker in accordance with the related laws and regulations and electric company standards.

23

Image 25
Contents Operation & Installation Manual Contents Disposal of the old air conditioner Refrigerating circuit is leak-proof Safety Precautions Safety Precautions Automatic Operation Features and FunctionsVertical AIR Direction Adjustment RIGHT/LEFT Name of Parts Cleaning and Care Operation and Performance Heating Performance Operation TipsLocation Installation of Indoor UnitSelecting the Mounting Position Indoor Unit Connection Pipe Requirement Drilling the Holes and Attaching the Suapension Bolts For HALF-CONCESLED Installation Installing the Coupler Heat Insulation Good Badbad 10mm or over Electrical Wiring Electrical Requirement FRESH-AIR Intake T N Customer Guidance Followings are not problems Trouble ShootingPoor cooling or heating Haier Group

HCFU-42HF03, HCFU-42CF03 specifications

The Frymaster HCFU-42HF03 and HCFU-42CF03 are advanced commercial fryers designed to optimize frying performance in high-volume kitchens. These models stand out for their exceptional efficiency, consistency, and user-friendly features, making them a popular choice among restaurant operators and food service establishments.

One of the most notable features of the HCFU series is its high-efficiency design. Both models incorporate advanced heating technologies that provide rapid heat-up times and maintain consistent frying temperatures. This is crucial for ensuring that food items are cooked evenly and in a timely manner, maximizing kitchen productivity.

The HCFU-42HF03 utilizes a gas-powered heating system, which offers quick recovery times and allows for higher temperature ranges. This is particularly beneficial for frying foods that require high oil temperatures, resulting in crispy, perfectly cooked dishes. On the other hand, the HCFU-42CF03 is an electric model, delivering impressive energy efficiency and reducing operating costs. The electric version is ideal for establishments looking to minimize their environmental impact while still delivering high-quality fried foods.

Both models feature a user-friendly digital control panel that simplifies operation. With adjustable temperature settings and programmable frying cycles, chefs can easily customize the cooking process for different food items. This ensures consistent results every time and reduces the learning curve for new staff.

Safety is a priority with the Frymaster HCFU series. These fryers come equipped with built-in safety features, including temperature limiting controls and automatic shut-off mechanisms. This not only protects the equipment from overheating but also ensures a safer kitchen environment for staff.

Additionally, the HCFU models are designed for easy cleaning and maintenance. The fryers are constructed with high-quality stainless steel, which is durable and easy to wipe down. The removable oil filtration system promotes optimal oil quality and prolongs the lifespan of the frying oil, ensuring that food maintains its flavor and quality over time.

In summary, the Frymaster HCFU-42HF03 and HCFU-42CF03 offer robust performance with their innovative heating technologies, user-friendly controls, and safety features. These fryers are an exceptional choice for any high-volume kitchen, providing efficiency, consistency, and ease of use for food service professionals.