Heatcraft Refrigeration Products CC-CUBZTB manual Medium & Low Temperature R-404A/507, 175

Page 20

Dual Vertical Air Discharge Condensing Unit

Electrical Data

Medium & Low Temperature – R-404A/507

 

 

Compressor

Condenser Fan

Beacon II™ or

 

Remote Loads

 

 

Compressor

Motors

Air Defrost

 

 

Unit Model

 

 

 

Electric Defrost

 

 

 

 

 

 

 

 

 

 

Number

Model

 

 

 

 

 

 

 

Evap.

Defrost

 

 

(2 Each)

RLA

LRA

Qty.

FLA

MCA

MOP††

System

System

 

Fan

Heaters

 

 

 

 

 

 

 

 

 

MCA

MOP††

 

 

 

 

 

 

 

 

 

Amps

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208-230 Volts

 

 

 

 

 

 

CDD*300BM6

4C2067PH

48.7

294

4

19.2

 

128.8

175

 

 

 

 

CDD*400BM6

4C2397PH

57.7

352

4

28.0

 

157.8

200

 

 

 

 

CDD*440BM6

4B2707PH

61.5

352

4

28.0

 

166.4

225

 

 

 

 

CDD*500BM6

4B3139PH

75.6

436

4

28.0

 

198.1

250

 

 

 

 

CDD*600BM6

4B3604PH

89.7

490

6

42.0

 

243.8

325

 

 

 

 

CDD*660BM6

6B4060PH

100.0

550

6

42.0

 

267.0

350

 

 

 

 

CDD*700BM6

6B4709PH

105.1

550

6

42.0

 

278.5

350

CONTACT FACTORY FOR SYSTEM

CDD*800BM6

6B5406PH

141.0

700

8

56.0

 

373.3

500

CDD*110BM6

6B6462PH

143.6

950

8

56.0

 

379.1

500

 

ELECTRICAL RATINGS

 

CDD*260BL6

4B2707PL

43.6

294

4

19.2

 

117.3

150

 

 

 

 

CDD*300BL6

4B3139PL

46.2

294

4

19.2

 

123.2

150

 

 

 

 

CDD*400BL6

4B3604PL

57.7

352

4

19.2

 

149.0

200

 

 

 

 

CDD*440BL6

6B4060PL

65.4

436

4

28.0

 

175.2

225

 

 

 

 

CDD*500BL6

6B4709PL

69.2

436

4

28.0

 

183.7

250

 

 

 

 

CDD*600BL6

6B5406PL

84.6

490

4

28.0

 

218.4

300

 

 

 

 

CDD*800BL6

6B6462PL

97.4

700

6

42.0

 

261.2

350

 

 

 

 

 

 

 

 

 

460 Volts

 

 

 

 

 

 

 

CDD*300BM6

4C2067PH

24.4

147

4

9.6

 

64.5

80

 

 

 

 

CDD*400BM6

4C2397PH

28.8

176

4

14.0

 

78.8

100

 

 

 

 

CDD*440BM6

4B2707PH

30.8

176

4

14.0

 

83.3

110

 

 

 

 

CDD*500BM6

4B3139PH

37.8

218

4

14.0

 

99.1

125

 

 

 

 

CDD*600BM6

4B3604PH

44.9

245

6

21.0

 

122.0

150

 

 

 

 

CDD*660BM6

6B4060PH

50.0

275

6

21.0

 

133.5

175

 

 

 

 

CDD*700BM6

6B4709PH

52.6

275

6

21.0

 

139.4

175

CONTACT FACTORY FOR SYSTEM

CDD*800BM6

6B5406PH

70.5

350

8

28.0

 

186.6

250

CDD*110BM6

6B6462PH

71.8

425

8

28.0

 

189.6

250

 

ELECTRICAL RATINGS

 

CDD*260BL6

4B2707PL

21.8

147

4

9.6

 

58.7

80

 

 

 

 

CDD*300BL6

4B3139PL

23.1

147

4

9.6

 

61.6

80

 

 

 

 

CDD*400BL6

4B3604PL

28.8

176

4

9.6

 

74.4

100

 

 

 

 

CDD*440BL6

6B4060PL

32.7

218

4

14.0

 

87.6

110

 

 

 

 

CDD*500BL6

6B4709PL

34.6

218

4

14.0

 

91.9

125

 

 

 

 

CDD*600BL6

6B5406PL

42.3

245

4

14.0

 

109.2

150

 

 

 

 

CDD*800BL6

6B6462PL

48.7

350

6

21.0

 

130.6

175

 

 

 

 

 

 

 

 

 

575 Volts

 

 

 

 

 

 

CDD*300BM6

4C2067PH

19.6

117

4

9.2

 

53.3

70

 

 

 

 

CDD*400BM6

4C2397PH

23.6

140

4

11.2

 

64.3

80

 

 

 

 

CDD*440BM6

4B2707PH

24.4

140

4

11.2

 

66.1

90

 

 

 

 

CDD*500BM6

4B3139PH

30.1

165

4

11.2

 

78.9

100

 

 

 

 

CDD*600BM6

4B3604PH

35.9

196

6

16.8

 

97.6

125

 

 

 

 

CDD*660BM6

6B4060PH

39.7

220

6

16.8

 

106.1

125

 

 

 

 

CDD*700BM6

6B4709PH

41.7

220

6

16.8

 

110.6

150

CONTACT FACTORY FOR SYSTEM

CDD*800BM6

6B5406PH

56.4

280

8

22.4

 

149.3

200

CDD*110BM6

6B6462PH

57.1

340

8

22.4

 

150.9

200

 

ELECTRICAL RATINGS

 

CDD*260BL6

4B2707PL

17.3

117

4

9.2

 

48.1

60

 

 

 

 

CDD*300BL6

4B3139PL

18.6

117

4

9.2

 

51.1

70

 

 

 

 

CDD*400BL6

4B3604PL

23.1

140

4

9.2

 

61.2

80

 

 

 

 

CDD*440BL6

6B4060PL

26.3

174

4

11.2

 

70.4

90

 

 

 

 

CDD*500BL6

6B4709PL

27.6

174

4

11.2

 

73.3

100

 

 

 

 

CDD*600BL6

6B5406PL

33.3

196

4

11.2

 

86.1

110

 

 

 

 

CDD*800BL6

6B6462PL

39.1

280

6

16.8

 

104.8

125

 

 

 

 

CDD* = CDDS is Beacon II, CDD*PP is Parallel Piped

† MCA = Minimum Circuit Ampacity

†† MOP = Maximum Overcurrent Protection

‡ Condensing unit data plate ratings will be based on actual system match.

20

Image 20
Contents Climate Control Table of Contents Five Year Warranty Options Head Pressure Control Bitzer Quiet Bitzer Compressors Features and BenefitsBitzer Offers Octagon 4C Models Centrifugal LubricationOLC-K1 Operating Principle Bitzer 4B & 6B ModelsHorizontal Discharge Temp. Range Refrigerant VoltagePerformance Data Medium Temperature R-404A/R-507Low Temperature R-404A/R-507 Medium Temperature R-404A/507 Electrical DataSpecifications and Dimensional Data Medium & Low Temperature R-404A/R-507Refrigerant Line Receiver Capacity Dimensions inches Approx Model LiquidStandard and Optional Features Factory-Installed OptionsModel Amb Medium Temperature R-404A/R-507Unit Model Compressor Suction Temp 90F 95F 100F 110F Low Temperature R-404A/R-507 CDV*130BL6Medium & Low Temperature R-404A/R-507 FLA MCA† MOP††Length a Dimensions InchesSuction Additional Standard Features for Parallel Piped Units Dual Vertical Air Discharge Condensing Unit Dual Vertical Air Discharge Condensing Unit Medium & Low Temperature R-404A/507 175Approx NetWt Lbs UnitModel Number Compressor 2Each Connectionsin.cLiquid Suction Page Page Cold You Can Count On