Trion T5200 Replacement Parts Ordering Information, VI. Warranty, VII. Troubleshooting Guide

Page 6

Wash Ionizing/ Collecting Cells

WARNING:

DO NOT USE HIGH PRESSURE STEAM CLEANING EQUIPMENT TO CLEAN CELLS. THE EXCESSIVE HEAT AND PRESSURE WILL CAUSE THE PLATES TO WARP AND IN TURN POSSIBLY CAUSE EXCESSIVE ARCING.

1.Turn the control switch “OFF” and disconnect power to the unit.

2.Open the cell access door.

3.Remove ionizer/collector cells and wash in HOT detergent water. If the collected contaminant is of extremely dry nature, it can be blown off the cells with a pressure hose or gently tapping the end plate of the cell.

4.Remove the mechanical pre-filter. Remove collected dust or lint by vacuuming or brushing. Wash with warm, soapy water.

5.Rinse all components thoroughly in warm, clear water and allow to drip dry completely.

6.Replace pre-filter and ionizer/collector cells. ENSURE the airflow arrows point in the direction of airflow (towards the blower).

7.Close the access door; reconnect power to the unit.

8.Turn control switch to “ON”. If arcing occurs or the indicating light flickers, the components may still be damp. Turn the unit OFF and allow the cells to dry completely.

Inspections

The motor and blower on Trion T5200 air cleaners have sealed ball bearings and never need lubricating.

Belt tension should be checked periodically. When a moderate force is applied to the belt midway between the pulleys, the belt should deflect approximately ½ “.

CAUTION

Having too much tension on the belts will shorten the belt life and place undue stress on the motor and blower bearings.

V. REPLACEMENT PARTS ORDERING INFORMATION

The following pages contain exploded views and Bills of Material for the Trion T Series Air Cleaners. Use these pages to determine the part numbers of the items needed. To order parts contact your local Trion representative and provide the following information:

a.Unit Model number – located on the data label near the junction box.

b.Part Number and description – from exploded views.

VI. WARRANTY

All Trion Electronic Air Cleaners are warranted for 3 Year Limited Warranty on units and 1 Year Limited Warranty on replacement parts. Labor is NOT included. Do not return defective parts without permission from the factory and receiving a material return acceptance number.

VII. TROUBLESHOOTING GUIDE

T5200 Problems and Possible Causes:

1.Indicating Light Out

a.Unit not plugged in

b.Control switch “Off”

c.Cell access panel not fully closed

d.Broken cell insulator

e.Extremely dirty cells

f.Service panel not secured in place

2.Excessive arcing noise after washing

a.Collector elements still wet – Allow more drying time

b.See “Continuous arcing noise” below

3.Continuous arcing noise and flickering indicating light

a.Extremely dirty collector plates

b.Bent collector plates

c.Large piece of material lodged between cell plates

4.Contaminant Bypass

a.Velocity of airflow is too high through unit

b.Collector plates not grounded

6

Image 6
Contents Air Boss Series Table of Contents Specifications II. Preparation for InstallationIII. Installation Read Thoroughly Ducting ApplicationElectrical Installation IV. MaintenanceLiquid Aerosol Application Installations Check Out for System Start-upVII. Troubleshooting Guide Replacement Parts Ordering InformationVI. Warranty T5200 Problems and Possible CausesT5200 Troubleshooting Guide Page Page Page Page Page Page

T5200 specifications

The Trion T5200 is an advanced piece of technology designed for high-performance computing tasks, meeting the demanding needs of various industries. This cutting-edge server system is tailored for businesses that require robust capabilities in data processing, storage, and network management.

One of the standout features of the Trion T5200 is its powerful processor options. It is equipped with the latest multi-core processors, providing exceptional processing power that enables simultaneous multitasking. This feature is crucial for applications that demand heavy computational resources, such as machine learning, data analytics, and real-time transaction processing.

In terms of memory, the Trion T5200 supports high-capacity RAM configurations, allowing for enhanced performance during intensive workloads. The system can handle substantial memory demands, ensuring that large datasets can be processed efficiently without bottlenecks. The expandable memory architecture also enables organizations to upgrade their systems as their needs grow.

Storage is another critical aspect of the Trion T5200. The system is equipped with a flexible storage architecture that supports various configurations of SSDs and HDDs. Users can opt for high-speed SSDs to ensure rapid data access and reduced latency or traditional HDDs for larger capacity requirements. The combination of high-performance storage options makes the T5200 ideal for both transactional and analytical workloads.

Networking capabilities are also a highlight of the Trion T5200. It provides multiple high-speed networking interfaces, including support for 10GbE and higher options, which facilitate fast data transfer and robust connectivity. This feature is essential for businesses that rely on cloud computing, virtualization, and expansive data center operations.

The Trion T5200 is designed with energy efficiency in mind. It incorporates advanced power management technologies that reduce energy consumption without compromising performance. This feature not only leads to cost savings but also aligns with the growing emphasis on sustainability in IT infrastructures.

In addition to hardware performance, the Trion T5200 supports advanced security features to protect sensitive data and ensure compliance with industry standards. This includes hardware-based security elements and robust software solutions designed to safeguard against evolving cyber threats.

Overall, the Trion T5200 stands out as a versatile and powerful server system that is built for the future. Its combination of high performance, scalability, and innovative technologies positions it as an ideal choice for organizations looking to enhance their computing capabilities and meet today’s challenges in the digital landscape.