Sebo X5, X4 manual Trouble-Shooting Guide, Problem Reason Solution

Page 10

Trouble-Shooting Guide

!Always unplug vacuum from outlet before dismantling any part of the machine!

PROBLEM

REASON

SOLUTION

 

 

 

 

Does not turn on

1. Handle not fully inserted into the bag

1.

Release handle catch, push handle

or machine shuts off

 

housing, causing a faulty connection.

 

down, close handle catch.

intermittently

 

 

 

 

2.

Not plugged into good outlet.

2.

Use another outlet.

 

 

 

 

 

 

 

3.

Cable worn.

3.

Replace cable.

 

 

 

 

 

 

4.

Dust bag housing (6) not seated

4.

Housing release button (8) should

 

 

fully into proper “locked” position

 

be snapped outward to its locked

 

 

on top of power head.

 

position.

 

 

 

 

 

Bag full or clog light on

1.

Bag full.

1.

Replace bag. See #5 on page 4.

or flashing &

 

 

 

 

2.

Clog in airflow pathway, attach-

2.

See Clog Removal on page 9.

machine shuts off

 

 

ment hose, attachment tube, swivel

 

Also, see #5 on page 4.

 

 

neck or entrance to dust bag.

 

 

 

 

 

 

 

 

3.

Microfilter dirty.

3.

Replace microfilter.

 

 

 

Brush light on

1. Brush worn.

1. See #3 on page 4.

 

 

 

Brush light slowly

1. Vacuum is stationary and in

1. See #4 on page 4.

flashing

 

upright locked position.

 

 

 

 

 

Brush light flashing &

1. Brush jammed.

1. See #2 on page 4.

machine shuts off

 

 

 

 

 

 

 

 

 

Up & down lights flicker

1.

Operating on uneven floor.

1.

Ignore.

 

 

 

 

 

Does not pick up

1.

Attachment tube not

1.

Reinsert attachment tube, making

 

 

correctly inserted.

 

sure lower end of tube is in the

 

 

 

 

lower hole and handle is properly

 

 

 

 

seated over the projection tab (22).

 

 

 

 

 

 

2.

Front cover not closed.

2.

See below.

 

 

 

 

 

Front bag door won’t

1.

Cover release flap not fully closed.

1.

Reinsert bag. Lock the cover

fully close

 

 

 

release flap down firmly.

 

 

 

 

 

 

2.

Bag not inserted properly

2.

Reinsert bag with cover release

 

 

 

 

flap (5) up, until firmly latched in

 

 

 

 

bag holder (see pg. 8, figure 7).

 

 

 

 

 

 

3.

Microfilter not properly inserted.

3.

Lift safety lever and insert filter with

 

 

 

 

vertical plastic ridge on filter facing

 

 

 

 

you (see pg. 8, figure 8).

 

 

 

 

 

Hose doesn’t retract

1.

Attachment tube not properly

1.

Reinsert making sure top of handle

after attachment tube is

 

inserted.

 

is pointing back and tube is fully

inserted

 

 

 

seated on the protruding tab (22)

 

 

 

 

on top of the dust bag housing.

 

 

 

 

 

Page 10

Image 10
Contents Sebo automatic Series Wiring Diagram Table of ContentsTechnical Details Important Safety Instructions Special Sebo Product Features Assembly Identification of PartsStarting The Machine Operating InstructionsOperating Positions Adjustment Wheel Figures 5 Using the Attachment Tube Hose & Attachments Figures 1, 2Display Panel Figure Maintenance Clogs in the Attachment Tube Active Wand Figure Clogs in the Airflow Pathway FigureClogs in the Attachment Hose Figure Clogs in Entrance to Dust Bag FigureTrouble-Shooting Guide Problem Reason SolutionSebo automatic Base Sebo automatic Sebo Vacuum Cleaner Warranty