Shinco KFR-25GWZ BM service manual

Page 22

Shinco Service Manual

98

0.3253

0.3536

0.3840

99

0.3156

0.3433

0.3730

100

0.3063

0.3333

0.3624

101

0.2973

0.3237

0.3522

102

0.2886

0.3144

0.3423

103

0.2802

0.3055

0.3327

104

0.2721

0.2968

0.3235

105

0.2643

0.2885

0.3146

106

0.2568

0.2804

0.3059

107

0.2495

0.2726

0.2976

108

0.2424

0.2650

0.2895

109

0.2356

0.2577

0.2817

110

0.2290

0.2507

0.2741

111

0.2227

0.2438

0.2668

112

0.2165

0.2372

0.2597

113

0.2106

0.2309

0.2529

114

0.2048

0.2247

0.2462

115

0.1993

0.2187

0.2398

116

0.1939

0.2129

0.2336

117

0.1887

0.2073

0.2276

118

0.1837

0.2019

0.2217

119

0.1788

0.1966

0.2161

120

0.1741

0.1916

0.2106

121

0.1695

0.1866

0.2053

122

0.1651

0.1819

0.2002

123

0.1608

0.1772

0.1952

124

0.1567

0.1728

0.1903

125

0.1527

0.1684

0.1857

126

0.1488

0.1642

0.1811

127

0.1450

0.1602

0.1767

128

0.1414

0.1562

0.1725

129

0.1379

0.1524

0.1683

130

0.1344

0.1487

0.1643

131

0.1311

0.1451

0.1604

132

0.1279

0.1416

0.1566

133

0.1248

0.1382

0.1530

134

0.1218

0.1349

0.1494

135

0.1188

0.1318

0.1459

136

0.1160

0.1287

0.1426

137

0.1132

0.1257

0.1393

138

0.1106

0.1228

0.1362

139

0.1080

0.1199

0.1331

140

0.1055

0.1172

0.1301

141

0.1030

0.1145

0.1272

142

0.1007

0.1120

0.1244

143

0.0984

0.1095

0.1217

144

0.0961

0.1070

0.1190

145

0.0940

0.1047

0.1165

146

0.0919

0.1024

0.1140

147

0.0898

0.1001

0.1115

148

0.0878

0.0980

0.1092

149

0.0859

0.0959

0.1069

150

0.0840

0.0938

0.1046

-8.0% -8.1% -8.1% -8.2% -8.2% -8.3% -8.3% -8.4% -8.4% -8.5% -8.5% -8.6% -8.6% -8.7% -8.7% -8.8% -8.8% -8.9% -8.9% -9.0% -9.0% -9.1% -9.1% -9.2% -9.2% -9.3% -9.3% -9.4% -9.4% -9.5% -9.5% -9.5% -9.6% -9.6% -9.7% -9.7% -9.8% -9.8% -9.8% -9.9% -9.9% -10.0% -10.0% -10.1% -10.1% -10.1% -10.2% -10.2% -10.3% -10.3% -10.3% -10.4% -10.4%

8.6%

8.7%

8.7%

8.8%

8.9%

8.9%

9.0%

9.0%

9.1%

9.2%

9.2%

9.3%

9.4%

9.4%

9.5%

9.5%

9.6%

9.7%

9.7%

9.8%

9.8%

9.9%

9.9%

10.0%

10.1%

10.1%

10.2%

10.2%

10.3%

10.3%

10.4%

10.4%

10.5%

10.6%

10.6%

10.7%

10.7%

10.8%

10.8%

10.9%

10.9%

11.0%

11.0%

11.1%

11.1%

11.2%

11.2%

11.3%

11.3%

11.4%

11.4%

11.5%

11.5%

- 22 -

Image 22
Contents Inverter Split system Air Conditioner R410A Model Annex PCB diagram Schematic diagram Remote controller PartIndoor panel Outdoor panel Outline Dimension of Indoor and Outdoor Units Outdoor unitIndoor unit KFR-50GWZ/BM KFR-70GWZ/BM Specification Wiring Diagram Indoor unit Wiring diagram KFR-25GWZ/BMKFR-50GWZ/BM KFR-70GWZ/BM Outdoor unit Wiring diagram KFR-25GWZ/BM KFR-50GWZ/BM KFR-70GWZ/BM Refrigerant system diagram Piping length and height difference Additional refrigerant Charge R410AgSensor Resistance Table KFR-25GWZ/BM、KFR-35GWZ/BM Sensor Resistance TablePage Page Indoor air sensor R25=5K±2% B25/50=3950K±2% Datasheet KFR-50GWZ/BM、KFR-70GWZ/BM Sensor Resistance TablePage Page Page Indoor pipe sensor R0=188.1K±4% ;B0/503877K±3% R-T datasheet Page Temp. Rmin KΩ Rcent KΩ Rmax KΩ ΔRmin ΔRmax Page Page Page Page Page Page Parts List and exploding view Exploding view and part list of KFR-25GWZ/BM Indoor unitOutdoor unit Part Name Quantity Page PVC Outdoor unit Part Name Quantity Exploding view and part list of KFR-50GWZ/BM Indoor unit Part Name Quantity BOM codeOutdoor unit Part Name Quantity BOM code Exploding view and part list of KFR-70GWZ/BM Indoor unit Outdoor unit Eb38676 Service warning Frequency table Fan-only mode Cooling modeOutdoor heat exchanger anti-overheated Dehumidifying mode Heating modeFrequency control during operation Indoor heat exchanger anti-overheated Refrigerant charge mode ProtectionLow voltage protection 、Display lamp Well Fault Page KFR-50GWZ/BM、KFR-70GWZ/BM Indoor Unit DON’T Match KFR-25GWZ/BM、KFR-35GWZ/BM 、 Outdoor power board 、 Outdoor diver board 、 Outdoor PFC board KFR-50GWZ/BM 、Outdoor power board 、outdoor driver board KFR-70GWZ/BM 、Indoor driver board 、 outdoor power board 、outdoor driver board Schematic 、 Outdoor power board 、Outdoor diver board 、Outdoor PFC board KFR-50GWZ/BM 、 outdoor power board 、 outdoor driver board KFR-70GWZ/BM 、Indoor driver board 、 outdoor power board 、outdoor driver board

KFR-25GWZ BM, KFR-25GWZ, BM specifications

The Shinco BM and KFR-25GWZ series represent a significant advancement in air conditioning technology, combining efficiency, performance, and user-centric features. Designed for both residential and small commercial applications, these models aim to provide optimal comfort while minimizing energy consumption.

One of the standout features of the Shinco BM series is its impressive energy efficiency rating, which helps to reduce electricity bills while still delivering powerful cooling and heating performance. The models are equipped with advanced inverter technology that allows for variable speed operation. This means that rather than cycling on and off entirely, the compressor adjusts its speed according to the required cooling or heating load. This not only results in a more consistent temperature but also extends the lifespan of the unit.

The KFR-25GWZ model integrates a multi-stage filtration system that ensures cleaner air quality. This system effectively captures dust, allergens, and other airborne particles, promoting a healthier indoor environment. Additionally, these units often feature a self-cleaning function which helps maintain the cleanliness of the internal components, enhancing efficiency and longevity.

User-friendly interfaces are another hallmark of the Shinco series. The remote control and optional Wi-Fi connectivity allow users to monitor and adjust settings from their smartphones or tablets. Features like programmable timers, sleep modes, and multiple fan speeds further enhance convenience.

In terms of design, the KFR-25GWZ is both sleek and modern, making it a perfect fit for various interior aesthetics. Its compact design ensures that it can be installed in a range of spaces without being obtrusive.

The noise levels of both the BM and KFR-25GWZ units are impressively low, making them suitable for bedrooms, offices, and other areas where quiet operation is essential. Enhanced insulation within the units minimizes sound, allowing users to enjoy their space without distraction.

Safety features including automatic restart after a power outage and overcurrent protection make these air conditioners reliable choices for households and businesses alike. Additionally, the environmentally friendly refrigerants used in these models contribute to lower global warming potential, aligning with contemporary sustainability goals.

In conclusion, the Shinco BM and KFR-25GWZ series showcase a blend of innovative technology, energy efficiency, and user-friendly features, making them an excellent choice for those looking to enhance their indoor comfort in a sustainable way.