Shinco KFR-25GWZ BM service manual KFR-25GWZ/BM、KFR-35GWZ/BM Sensor Resistance Table

Page 16

Shinco Service Manual

7.Sensor Resistance Table

7.1 KFR-25GWZ/BMKFR-35GWZ/BM Sensor Resistance Table

7.1.1indoor air sensor、indoor pipe sensor、outdoor air sensor、outdoor pipe sensor

R-T datasheet

10K±0.5% ;3976K±0.5%,B(25/85)=3976K±0.5%

R-T datasheet

 

 

 

 

 

 

 

 

 

 

 

Temp.()

R(KΩ)

Temp.()

R(KΩ)

Temp.()

R(KΩ)

 

Temp.()

R(KΩ)

 

-30

180.719

4

26.832

38

5.764

 

72

1.627

 

-29

169.891

5

25.522

39

5.534

 

73

1.573

 

-28

159.763

6

24.284

40

5.315

 

74

1.522

 

-27

150.289

7

23.113

41

5.105

 

75

1.472

 

-26

141.422

8

22.006

42

4.905

 

76

1.425

 

-25

133.124

9

20.958

43

4.713

 

77

1.379

 

-24

125.355

10

19.967

44

4.530

 

78

1.335

 

-23

118.079

11

19.028

45

4.355

 

79

1.293

 

-22

111.264

12

18.139

46

4.188

 

80

1.252

 

-21

104.879

13

17.297

47

4.028

 

81

1.213

 

-20

98.895

14

16.499

48

3.875

 

82

1.176

 

-19

93.284

15

15.742

49

3.728

 

83

1.140

 

-18

88.023

16

15.024

50

3.588

 

84

1.105

 

-17

83.089

17

14.344

51

3.454

 

85

1.072

 

-16

78.458

18

13.698

52

3.325

 

86

1.040

 

-15

74.112

19

13.085

53

3.202

 

87

1.009

 

-14

70.032

20

12.503

54

3.084

 

88

0.980

 

-13

66.200

21

11.950

55

2.971

 

89

0.951

 

-12

62.599

22

11.425

56

2.863

 

90

0.924

 

-11

59.216

23

10.926

57

2.760

 

91

0.897

 

-10

56.035

24

10.451

58

2.660

 

92

0.872

 

-9

53.044

25

10.000

59

2.565

 

93

0.848

 

-8

50.231

26

9.571

60

2.474

 

94

0.824

 

-7

47.583

27

9.162

61

2.386

 

95

0.802

 

-6

45.091

28

8.773

62

2.302

 

96

0.780

 

-5

42.744

29

8.403

63

2.221

 

97

0.760

 

-4

40.534

30

8.051

64

2.144

 

98

0.740

 

-3

38.451

31

7.715

65

2.070

 

99

0.720

 

-2

36.487

32

7.395

66

1.998

 

100

0.702

 

-1

34.636

33

7.090

67

1.930

 

101

0.684

 

0

32.890

34

6.799

68

1.864

 

102

0.667

 

1

31.242

35

6.522

69

1.801

 

103

0.651

 

2

29.687

36

6.257

70

1.741

 

104

0.635

 

3

28.219

37

6.005

71

1.683

 

105

0.620

- 16 -

Image 16
Contents Inverter Split system Air Conditioner R410A Model Annex PCB diagram Schematic diagram Remote controller PartIndoor panel Outdoor panel Outline Dimension of Indoor and Outdoor Units Outdoor unitIndoor unit KFR-50GWZ/BM KFR-70GWZ/BM Specification Wiring Diagram Indoor unit Wiring diagram KFR-25GWZ/BMKFR-50GWZ/BM KFR-70GWZ/BM Outdoor unit Wiring diagram KFR-25GWZ/BM KFR-50GWZ/BM KFR-70GWZ/BM Refrigerant system diagram Piping length and height difference Additional refrigerant Charge R410AgSensor Resistance Table KFR-25GWZ/BM、KFR-35GWZ/BM Sensor Resistance TablePage Page Indoor air sensor R25=5K±2% B25/50=3950K±2% Datasheet KFR-50GWZ/BM、KFR-70GWZ/BM Sensor Resistance TablePage Page Page Indoor pipe sensor R0=188.1K±4% ;B0/503877K±3% R-T datasheet Page Temp. Rmin KΩ Rcent KΩ Rmax KΩ ΔRmin ΔRmax Page Page Page Page Page Page Parts List and exploding view Exploding view and part list of KFR-25GWZ/BM Indoor unitOutdoor unit Part Name Quantity Page PVC Outdoor unit Part Name Quantity Exploding view and part list of KFR-50GWZ/BM Indoor unit Part Name Quantity BOM codeOutdoor unit Part Name Quantity BOM code Exploding view and part list of KFR-70GWZ/BM Indoor unit Outdoor unit Eb38676 Service warning Frequency table Fan-only mode Cooling modeOutdoor heat exchanger anti-overheated Dehumidifying mode Heating modeFrequency control during operation Indoor heat exchanger anti-overheated Refrigerant charge mode ProtectionLow voltage protection 、Display lamp Well Fault Page KFR-50GWZ/BM、KFR-70GWZ/BM Indoor Unit DON’T Match KFR-25GWZ/BM、KFR-35GWZ/BM 、 Outdoor power board 、 Outdoor diver board 、 Outdoor PFC board KFR-50GWZ/BM 、Outdoor power board 、outdoor driver board KFR-70GWZ/BM 、Indoor driver board 、 outdoor power board 、outdoor driver board Schematic 、 Outdoor power board 、Outdoor diver board 、Outdoor PFC board KFR-50GWZ/BM 、 outdoor power board 、 outdoor driver board KFR-70GWZ/BM 、Indoor driver board 、 outdoor power board 、outdoor driver board

KFR-25GWZ BM, KFR-25GWZ, BM specifications

The Shinco BM and KFR-25GWZ series represent a significant advancement in air conditioning technology, combining efficiency, performance, and user-centric features. Designed for both residential and small commercial applications, these models aim to provide optimal comfort while minimizing energy consumption.

One of the standout features of the Shinco BM series is its impressive energy efficiency rating, which helps to reduce electricity bills while still delivering powerful cooling and heating performance. The models are equipped with advanced inverter technology that allows for variable speed operation. This means that rather than cycling on and off entirely, the compressor adjusts its speed according to the required cooling or heating load. This not only results in a more consistent temperature but also extends the lifespan of the unit.

The KFR-25GWZ model integrates a multi-stage filtration system that ensures cleaner air quality. This system effectively captures dust, allergens, and other airborne particles, promoting a healthier indoor environment. Additionally, these units often feature a self-cleaning function which helps maintain the cleanliness of the internal components, enhancing efficiency and longevity.

User-friendly interfaces are another hallmark of the Shinco series. The remote control and optional Wi-Fi connectivity allow users to monitor and adjust settings from their smartphones or tablets. Features like programmable timers, sleep modes, and multiple fan speeds further enhance convenience.

In terms of design, the KFR-25GWZ is both sleek and modern, making it a perfect fit for various interior aesthetics. Its compact design ensures that it can be installed in a range of spaces without being obtrusive.

The noise levels of both the BM and KFR-25GWZ units are impressively low, making them suitable for bedrooms, offices, and other areas where quiet operation is essential. Enhanced insulation within the units minimizes sound, allowing users to enjoy their space without distraction.

Safety features including automatic restart after a power outage and overcurrent protection make these air conditioners reliable choices for households and businesses alike. Additionally, the environmentally friendly refrigerants used in these models contribute to lower global warming potential, aligning with contemporary sustainability goals.

In conclusion, the Shinco BM and KFR-25GWZ series showcase a blend of innovative technology, energy efficiency, and user-friendly features, making them an excellent choice for those looking to enhance their indoor comfort in a sustainable way.