➥Cancelling User Disable in Management/Employee Access Mode
If you decide user code holders should no longer have the ability to disable the lock, perform the following procedure.
56 ✽ master code #♪♪♪♪♪0 #♪♪♪0 #♪♪♪
User code holders will no longer be able to disable the lock, although the master code holder and supervisor code holder will still have the ability to do so.
➥Taking the Lock Out of Management/Employee Access Mode
If you no longer want the lock to function in the management/ employee access mode, enter the following sequence.
32 ✽ master code or supervisor code #♪♪♪♪♪1 #♪♪♪1 #♪♪♪
The lock will now operate on any valid code at any time.
Managing Duress
➥Turning Duress ON
If your lock was ordered with time duress capability and an optional duress module is installed, the feature can be turned on as follows.
38 ✽ master code #♪♪♪♪♪1 #♪♪♪1 #♪♪♪
➥Turning Duress OFF
The duress feature can be turned off as follows.
38 ✽ master code #♪♪♪♪♪0 #♪♪♪0 #♪♪♪
➥Verifying Duress
If duress is enabled, you can tell if the lock has sent a silent alarm. Fifteen minutes or more after a duress signal has been sent, press and hold down the ✽ button for at least four seconds. The lock will emit a continuous alternating series of high and low pitch beeps to indicate that a duress signal has been sent. Reset the duress indication by entering the lock’s master code within one minute after the verification signal ends.
Managing Audit Trail
➥Capturing an Audit Trail
Your lock must have been ordered with this option. Using the audit trail feature also requires an optional keypad extension (S&G part number
2 8 ✽ master code #
The lock will beep three times when the download is complete. You may then remove your iButton key from the keypad extension’s receptacle. The information now stored in the key is a copy of what is in the lock. The lock’s audit information is not erased in the download process.