Important!

Transport the unit in an upright position only, or leave it in an upright position for at least 2 hours before first use.

Always place the unit on an even surface (Figure 1).

Make sure the unit is connected to a correctly grounded power supply (refer to the rating label located at the back of the unit).

An opening in a window or wall is required to accommodate the exhaust hose (kit supplied) to expel the warm air.

Do not cover or obstruct the appliance inlet or outlet grilles (Figure 2).

To avoid the risk of shock, the product should never be used

in bathrooms, shower rooms or in any other steamy or wet areas.

The unit will cool when the room temperature is between 64°F and 110°F depending on the thermostat setting.

Do not sit or place objects on the unit.

Do not touch the unit with wet/damp hands or when standing barefoot.

Avoid all contact with chemical based materials.

The filter must be used with the product at all times. When removing for cleaning, always disconnect the unit from the mains first.

Turn off the appliance when not in use.

At the end of each season all water must be drained and the unit and filters cleaned before storage.

Drainage of the water container is required before moving the unit or putting it into storage.

If the electric socket is different from the plug provided, have a professionally qualified electrician replace the plug with a suitable one. Avoid the use of adaptor plugs, multiple sockets and/or extension leads; if their use is necessary, ensure that they conform to the

current safety regulations.

Do not pull the supply cable or place it near a source of heat;

always unroll it completely to avoid the possibility of dangerous overheating.

If the supply cord is damaged, it must be replaced by the service agent or a similarly qualified person.

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.

Fig. 1

Fig. 2

Operation - Mechanical Models

Setting the Temperature

Turn the THERMOSTAT to regulate the temperature you desire: range 64°F to 90°F.

Setting the Timer

Turn the TIMER to the desired operating time (1 to 8 hours).

When the set time has elapsed, the machine will shut off automatically.

Regulating the Airflow Direction

Turn the roller on the air vent to control

the airflow direction from the vertical louvres.

NOTICE!

The compressor will start approximately 3 minutes after the unit is turned on (this will help prolong the life of the compressor). After switching the unit off, please wait at least 3 minutes before turning the unit back on.

The cooling system will switch off if the room temperature is lower than set.The fan, however, keeps working at the set level. If the ambient temperature rises above the chosen level +5°,

the cooling will resume.

4

9

Image 6
Contents Air Conditioner Troubleshooting Table of ContentsBy the Draining into a Container SpecificationsDrainage By Water Tube Continuous DrainageOperation Mechanical Models AccessoriesSetting Function / Ventilation Speed PartsMounting the unit InstallationInstallation of the Carbon Filter Mounting the exhaust pipeBefore Use Setting the TemperatureSetting the Timer Regulating the Airflow DirectionMaintenance Thank YouDefective Notice

WA-7500M specifications

The Sunpentown International WA-7500M is an innovative evaporative air cooler designed to enhance indoor air comfort during hot weather. Featuring a compact design, it efficiently cools spaces while remaining energy-efficient, making it an ideal choice for those looking to maintain a comfortable environment without incurring high electricity bills.

One of the standout features of the WA-7500M is its advanced evaporative technology, which works by absorbing heat from the air and replacing it with cool, refreshing airflow. This process not only lowers the temperature in your room but also adds moisture to the air, benefiting individuals who suffer from dry skin or respiratory issues. With a powerful motor, the cooler can effectively circulate air across larger areas, ensuring that your entire living space remains comfortable.

The WA-7500M is equipped with multiple speed settings, allowing users to customize the airflow to their preference. Whether you need a gentle breeze or powerful cooling, this unit provides flexibility to match your comfort needs. The unit also features a large water tank capacity, minimizing the frequency of refills and enabling longer operation times. Conveniently, a water level indicator lets users easily monitor the remaining water and plan refills accordingly.

Portability is another hallmark of the WA-7500M. Designed with caster wheels, this air cooler can be effortlessly moved from room to room. Whether you want it in your living room, bedroom, or office, its lightweight design facilitates easy relocation without hassle. Additionally, the unit operates with minimal noise, allowing it to be used in quiet environments, such as during sleep or meetings.

The WA-7500M includes essential safety features such as an automatic shut-off function to prevent overheating and ensure safe operation. The user-friendly control panel offers easy access to settings and configurations, making it simple for anyone to operate.

In summary, the Sunpentown International WA-7500M is a comprehensive solution for cooling and humidifying indoor spaces. With its efficient design, powerful capabilities, and user-friendly features, it stands out as an impressive option for anyone looking to beat the heat while maintaining energy efficiency.