Windsor 10052270, SCE264 operating instructions Changing Batteries

Page 23

5.Replace the battery caps, and leave them in place while charging.

6.Unplug the battery connector from the machine.

FOR SAFETY: When charging, connect the charger to the batteries before connecting the charger to the AC wall outlet. Never connect the charger to the AC wall outlet first. Hazardous sparks may result.

7.Plug the charger connector into the battery connector. Connect the charger AC plug to a wall outlet. The charger gauge should indicate that the batteries are charging.

8.When the batteries are fully charged, disconnect the charger from the AC wall outlet, then disconnect the charger from the batteries.

9.Connect the batteries to the machine connector.

10.Check the electrolyte level. It should be up to the indicator ring. If necessary, add distilled water.

11.Lower the battery cover.

MAINTENANCE

CHANGING BATTERIES

Stop the machine in a clean area next to the charger. Turn off machine.

FOR SAFETY: Before leaving or servicing the machine; stop on level surface, turn off machine and remove key.

1.Raise the battery cover.

2.Disconnect battery pack from machine.

3.Use the proper size open end wrench to disconnect main ground wire first and secure cable terminal away from batteries.

4.Disconnect main positive lead and secure cable terminals away from batteries.

5.Loosen both terminals on each jumper cable and remove one at a time.

6.Prepare a suitable site to place the batteries.

7.Attach suitable battery lifting device and lift batteries from the machine.

Batteries are a potential

!environmental hazard. Consult your battery supplier for safe disposal methods.

FRONT OF MACHINE

CUTTER 24V (SCE) 86037010 02/21/07

4-5

 

Image 23
Contents Walk Behind Scrubber Overview Machine Data LOG/OVERVIEWYour Dealer Table of Contents Model HOW to USE this ManualRead ALL Instructions Before Using this Machine Important Safety InstructionsHazard Intensity Level Hazard Intensity LevelSafety Label Location DIMENSION/CAPACITY Technical SpecificationsMeasure Special NotesHOW the Machine Works Components Controls Brush Switch KEY SwitchEmergency SHUT-OFF Switch Squeegee Lift Lever Solution Control KnobVacuum Switch Squeegee Pitch Adjustment KnobHour Meter Parking BrakePRE-RUN Machine Inspection Emergency Stop ProceduresFilling Solution Tank Machine OperationTo Stop Scrubbing Normal ScrubbingTo Begin Scrubbing Double Scrub Emptying and Cleaning TanksHRS Maintenance Service ScheduleMaintenance Daily Weekly Monthly Maintenance Batteries Battery MaintenanceTo Charge the Batteries Checking Battery Specific GravityBattery Condition Changing Batteries To Replace or Rotate Rear Squeegee Blades Adjusting SqueegeeTo Remove Squeegee Assembly Squeegee BladesTo Replace AQUA-MIZER Squeegee Blades To Adjust Squeegee PitchTo Adjust Amount of Rear Squeegee Deflection Uncoated Floors Replacing or Installing Scrub BrushesRecovery Tank Float SHUT-OFF Scrub BrushesChanging Brush Motors Solution StrainerBrush Motor Carbon Brush Replacement Brush MotorBrush Shrouds & Brush Skirts Traction Motor Carbon Brush ReplacementTraction Motor Circuit BreakersChanging Vacuum Motor Vacuum MotorRecommended Greasing Problem Cause Solution Machine TroubleshootingMachine Troubleshooting This page Left Blank Intentionally

10052270, SCE264 specifications

Windsor SCE264,10052270 is a cutting-edge product designed to meet the demands of modern spaces. This model is especially recognizable for its robust construction and adaptability, making it suitable for a variety of applications, whether in commercial or industrial environments.

One of the main features of the Windsor SCE264 is its advanced climate control technology. This system enables efficient temperature regulation, ensuring optimal comfort levels while minimizing energy consumption. The integration of smart sensors allows for real-time monitoring, enabling the adjustment of settings based on occupancy and external weather conditions. This smart technology not only enhances user experience but also contributes to energy savings, aligning with sustainability goals.

In terms of design, the Windsor SCE264 boasts a sleek and contemporary aesthetic. Its compact size allows it to fit seamlessly into various layouts, whether in offices, retail spaces, or manufacturing facilities. Despite its small footprint, it does not compromise on performance, featuring a high-output capacity that can efficiently cater to larger spaces without difficulty.

The unit is equipped with state-of-the-art filtration systems that ensure high air quality. These filters capture fine particles and allergens, making it an excellent choice for environments where cleanliness is paramount. The Windsor SCE264 is not just about functionality; it prioritizes the health and well-being of users, making it a preferred choice in hospitals, educational institutions, and other critical environments.

Technologically, Windsor has integrated IoT capabilities into the SCE264, enabling users to control and monitor the device remotely. This feature is particularly beneficial for facility managers who require constant oversight or for users who wish to adjust settings from their smartphones or other devices.

Safety is another key characteristic of the Windsor SCE264. It includes built-in mechanisms to prevent overheating and ensure reliable operation under various conditions. This reliability is crucial for maintaining operational continuity in critical scenarios.

In conclusion, the Windsor SCE264,10052270 stands out for its combination of innovative technology, efficient performance, health-conscious features, and user-friendly design. Whether used in commercial or industrial settings, it represents a significant advancement in climate control solutions, delivering comfort, efficiency, and reliability in one package.