Windsor E50 10070090 Maintenance, Unplug power cords before servicing or making any repairs

Page 12

MAINTENANCE

DAILY MAINTENANCE

Unplug power cord(s) before servicing or making any repairs.

1.Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hot water.

2.Vacuum out the solution tank.

3.Rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 1-10 bleach to water solution. Wastewater should be disposed of properly.

4.Occasionally check filter screen at the bottom of the solution tank and rinse clean with hot water if necessary.

5.Inspect hoses for wear. Frayed or cracked hoses should be replaced to avoid vacuum or solution pressure loss.

6.Inspect power cord for wear or damage. This cable will lie on wet carpet. To prevent electrical shock replace cords that are frayed or have cracked insulation immediately.

7.Clean all dirt and obstructions from drain valve and gaskets to prevent possible leakage and premature wear.

8.Run clean water through solution pump when work is complete.

9.Empty both tanks and rinse, run vacuum (s) for at least one minute to dry motor(s).

10.Store with access covers removed to allow tanks to dry.

DO NOT attempt to repair hose! Repairing high-

pressure hoses may result in severe burns and serious injury.

PERIODIC MAINTENANCE

1.Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the extractor, turning pump switch on/off several times, flush with clean water. This will prevent build-up of alkaline residue in the system.

2.Check hoses for wear, blockages, or damage. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure.

3.Check all handles, switches, knobs, electrical cables and connections on your machine for damage. If the cable insulation is broken or frayed, repair or replace it immediately. Don’t take chances with electrical fire or shock.

4.Clean out solution tank. Remove and clean solution screen.

5.Clean outside of all tanks and check for damage.

MONTHLY MAINTENANCE

1.Check all bearings for noise and wear.

2.Check all gaskets for wear and leakage.

3.Check pump pressure; observe spray pattern and check gauge if necessary.

4.Check overall performance of machine.

SEMI-ANNUALLY

1. Check vacuum motor brushes.

LUBRICATION

For hose fitting lubrication, use a light silicone lubricant which will not damage o-rings.

STORAGE

Thoroughly clean machine if it is to be stored. Protect this machine from freezing while in storage.

4-1

ENSIGN 86038250 02/12/07

Image 12
Contents Carpet Extractor Machine Data LOG/OVERVIEW Your DealerOverview Table of Contents HOW to USE this Manual ModelImportant Safety Instructions Read ALL Instructions Before Using this MachineHazard Intensity Level Hazard Intensity LevelSafety Label Location Grounding Instructions ElectricalExtension Cords Grounding InstructionsTechnical Specifications Controls VAC OFF PumpMachine Operation General InformationMaintenance Unplug power cords before servicing or making any repairsVacuum Motor Replacement Solution Pump Replacement Troubleshooting Pump Group PRV no QTY Description Serial no From Recovery Tank Group Float SHUT-OFF Tube W/ADPTR Solution Tank Group NIPPLE, 1/4FPT QD Vacuum Motor Group Brush SET,120V VAC Windsor Service only Wiring Diagram Suggested Spare Parts Ensign 86038250 02/12/07

E50 10070090 specifications

The Windsor E50 10070090 is a cutting-edge device designed to meet the demands of modern commercial environments. Known for its robust construction and versatile functionality, this model stands out as a reliable solution for businesses seeking efficiency and durability.

One of the main features of the Windsor E50 is its powerful cleaning capability. Equipped with a high-performing motor, the E50 provides consistent suction and superior cleaning results. This makes it ideal for a wide range of surfaces, from carpets to hard floors, ensuring that every nook and cranny is attended to. The machine's advanced brush system further enhances its cleaning performance, enabling it to tackle tough dirt and grime with ease.

In addition to its cleaning prowess, the Windsor E50 10070090 incorporates innovative technologies that enhance user experience and operational efficiency. Its ergonomic design allows for easy maneuverability, which is essential in large commercial spaces. The intuitive controls ensure that operators can adjust settings quickly, adapting to different cleaning scenarios without any hassle.

The Windsor E50 is also designed with maintenance in mind. Its easy-access components simplify the maintenance process, reducing downtime and prolonging the machine's lifespan. The robust construction materials used in the E50 contribute to its durability, ensuring that it withstands the rigors of daily use in demanding environments like hotels, hospitals, and schools.

Another standout characteristic of the E50 is its remarkable energy efficiency. With rising energy costs and a growing emphasis on sustainability, the Windsor E50 has been engineered to consume less power while delivering exceptional cleaning results. This aligns with many businesses' goals to reduce their carbon footprint and operational expenses.

Moreover, the Windsor E50 10070090 features a compact design that makes storage and transportation effortless. Its lightweight nature allows for easy handling, making it a practical choice for various cleaning professionals.

In summary, the Windsor E50 10070090 is a powerful, efficient, and user-friendly cleaning machine. Its top-notch cleaning performance, innovative technologies, ease of maintenance, energy efficiency, and compact design make it an excellent investment for any commercial cleaning operation. As businesses seek reliable solutions to maintain cleanliness standards, the Windsor E50 stands as a trusted option that meets and exceeds expectations.