Whynter ARC-12SDH instruction manual Window kit Installation

Page 10

Window kit Installation

When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in dehumidifying and fan-only mode, no exhaust is required.

Your window kit has been designed to fit most standard vertical and horizontal windows. However, it may be necessary for you to modify the installation procedures for your window.

NOTE: If your window opening is less than the mentioned minimum length of the window slider kit, cut the slide bar with hole to fit window opening. Never cut out the hole on the window slide bar.

NOTE: When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements may be needed.

1.Open window approximately 5”.

2.Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window.

3.Insert the fixtures through the back grooved side of the window slide bar with holes. Line up the 4 holes and tighten the fixtures with 4 screws from the front. Fig 1.

4.Close the window on the window slide bars. For long term installation, you may screw the window kit into your window frame.

5.Move the unit to the window, extend the hoses and attach the other end of the hoses to the window slide bar.

6.Align the slots on the hose connector to the tabs on the

fixtures and snap the hoses to the window slide bar.

Figure 1

10 P a g e

Image 10
Contents MODEL# ARC-12SDH Table of Contents Disposal Safety Precautions DRY Mode Room TemperatureOperating Condition HeatIdentification of Accessories Image Accessory Name QuantityIdentification of Parts Front Rear Operating Your AIR Conditioner Control PanelInstallation Instructions LocationWindow kit Installation AIR Filters Installation  Before Using Your Portable AIR Conditioner Operation InstructionsSetting Delayed Switch on Timer Setting Switch OFF TimerWater Drainage Installing Batteries Care and Maintenance Cleaning the PRE-FILTERTechnical Data ARC-12SDHTroubleshooting Problem Possible Causes SolutionsA g e ONE Year Limited Warranty Three Year Warranty on Compressor This Warranty does not Cover