Whynter ARC-12SDH instruction manual Care and Maintenance, Cleaning the PRE-FILTER

Page 15

CARE AND MAINTENANCE

IMPORTANT:

Switch off the air conditioner and disconnect the plug from the power outlet

Drain water by removing the drain plug.

Always transport the air conditioner in an upright position only.

CLEANING THE PRE-FILTER

To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the Pre-filter at least once every two weeks.

Switch off the air conditioner and pull out the filter frame from the unit.

Remove the Activated Carbon Filter from the Pre-filter.

Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the Pre-filter. Then rinse it thoroughly under warm or cold running water (no hotter than 100F.)

Dry thoroughly before re-inserting the filters.

NOTE:: The Activated Carbon Filter is not washable. It should be replaced every 2-3 months or as

needed.

WARNING! Never operate the air conditioner without the filter in place.

CLEANING THE AIR CONDITIONER

Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner.

Use a soft damp cloth to wipe the body of the unit.

Never use harsh chemicals, oil-based products, detergents, chemically treated cloths or other

cleaning solutions. These could possibly damage the body of the air conditioner.

END OF SEASON STORAGE

Switch off the air conditioner and disconnect the power plug from the power supply outlet before cleaning the air conditioner.

Clean the air filters.

Drain the condensed water COMPLETELY.

On a warm day, turn on the Fan only mode for half a day so that the inside can dry out completely.

Wrapped the power cord and bundle it with the tape.

Remove the batteries from the remote controller.

Disconnect the exhaust hose and cover the window / wall hole with the cover.

It is recommended that the air conditioner be put back into its original carton for storage.

15 P a g e

Image 15
Contents MODEL# ARC-12SDH Table of Contents Disposal Safety Precautions Heat Mode Room TemperatureOperating Condition DRYImage Accessory Name Quantity Identification of AccessoriesIdentification of Parts Front Rear Control Panel Operating Your AIR ConditionerLocation Installation InstructionsWindow kit Installation AIR Filters Installation Operation Instructions  Before Using Your Portable AIR ConditionerSetting Switch OFF Timer Setting Delayed Switch on TimerWater Drainage Installing Batteries Cleaning the PRE-FILTER Care and MaintenanceARC-12SDH Technical DataProblem Possible Causes Solutions TroubleshootingA g e This Warranty does not Cover ONE Year Limited Warranty Three Year Warranty on Compressor