STEP 6. Secure the end hinges, (one side only) center hinges, and strutting ( if applicable) as previously illustrated. Locate the Lock Section (usually the second section) and insert a roller into the end hinge. Stack this section into the opening by hooking the roller in the vertical track and lowering it onto the bottom section. Insert a roller into the appropriate end hinge and insert roller into vertical track on the opposite end. Secure end hinge to the section using the self-drilling and tapping screws. Align the

Spring mounting pad. 2 X 6 White Pine or denser. Secured with min.

(4) 5/16” x 4” lag bolts into header.

Steel

Pre-Cast

section edges, flip up the upper hinge leafs and secure to the lock section using the self-drilling and tapping screws. Continue to hardware and stack the remaining sections in the proper sequence. Attach the top brackets to the upper corners, of the top section, using self drilling and tapping screws as shown in Fig. J.

NOTE : Top section maybe installed now or may wait until the last step (installer preference)

STEP 7. Adjust the vertical track from 1/2” spacing at the bottom section to 3/4” at the top section. Refer to page 3. Permanently secure each vertical to the jambs using the following fasteners:

Steel Jambs: 5/16” x 1” self drilling and tapping screw.

Wood Jambs: 5/16” x 1-5/8” lag screw.

Precast or Block: 3/8” x 3” sleeve anchor.

The left hand vertical track assembly indicates the standard fastener spacing (Fig. K page 7).

STEP 8: Use chain or cable to temporarily suspend the rear of the horizontal tracks. Secure the horizontal reinforcing angle to the wall angle using (1) 3/8” x 3/4” truss bolt and nut, then secure the horizontal track to the splice plate or flagangle using (2) track bolts and hex flange nuts.

STEP 9: Torsion spring assemblies can be of several configurations depending on door size and weight. Left or right hand spring(s) must be identified by the color of the winding cone. (Refer to Fig. L and pages 8-10)

Assemble torsion spring system components to applicable configuration shown on pages 8-10. Ensure that spring warning tags are securely wired to all stationary spring cones.

WARNING: Install support brackets to solid structural members only. Do not install over dry wall or paneling.

NOTE: Use a chalk line or line level to ensure all support brackets are in line.

STEP 10: Position shaft(s) with spring system components to proper elevation, level and secure each end bracket to the horizontal reinforcing angle using (2) 3/8” x 3/4” truss bolts and nuts. Anchor the wall mounting flange of the end bracket to the jamb

Top plate

Header

(2)3/8” x 1” or 1-1/2” Bolts

(2) 3/8” Nuts

and Washers

5/16” x 1-5/8”

Lag Screws

Perimeter seal

Bearing Bracket

Sleeve anchor positioned in bottom slot of bearing bracket Perforated Angle

(Trimmed to clear door high-arc)

Sleeve Anchor (4)

NOTE: All anchors must be positioned a minimum of 1” from block edge.

Fig. N

5/16” x 1” Self-drilling and tapping screw

1/2” x 3” Sleeve anchor

NOTE: Must secure sleeve anchors to building first , then attach brackets to anchors.

3/8” X 1-1/4” Hex Head

Bolt and Nut (2)

Second anchor from bottom must be below bearing bracket

using (2) 5/16” x 1-5/8” lags (wood), (2) 5/16” x 1” self-drilling and tapping screws (steel), or (2) 3/8” x 3” sleeve anchors (precast).

NOTE: Spring pads must be securely anchored before proceeding. The pads must by flush with the jambs.

Alternate Steel Spring Pad Applications

Contact Manufacturer For Applications Not Covered Below

Attach the spring support brackets to the pad(s) using the following fasteners:

Pre-Cast: Secure each spring support bracket using (2) 1/2” x 3” sleeve anchors. This installation will require the 1/2” anchors to be secured to the building, then securing the brackets to the anchors as detailed in Fig. N Page 11.

Steel: Secure each spring support bracket using (3) 5/16” x 1” self-drilling and tapping screws as detailed in Fig. N Page 11.

Block Construction: Attach perforated angle 18” long to support bracket(s) using (2) 3/8” x 1-1/4” bolts and nuts. Chamfer angle to clear top section high arc. Secure support brackets and perforated angle to block using (4) 3/8” x 2-1/2” sleeve anchors as detailed in Fig. N Page 11.

Secure the stationary cone(s) (dead end) to the spring support bracket(s) using 3/8” bolts and nuts. Keep spring warning tags clearly visible.

NOTE: The coupler support brackets only require (2) fasteners. The spring support brackets require (2) fasteners in the lower slot and hole, then (1) fastener in the top slot.

WARNING: Failure to use proper number of fasteners can result in sudden spring tension release, causing severe injury or death.

NOTE: Each 3-3/4”, 6” and Duplex spring is secured to a separate center support bracket. DO NOT attach two springs of this size to one support bracket.

STEP 11: Feed the cable attached to the left hand bottom bracket up the vertical track, behind the roller shafts and secure to the left hand drum. Push the drum up against the end bearing bracket and secure to the shaft by tightening the set screws (solid shafts use 1/4” key(s) and set screws to secure drums).

Rotate drum and shaft until cable is taut, then apply vice grips to shaft, with end resting against header. This will hold cable taut and on drum. There must be at least 1/2 wrap of cable on the drum. If not, contact Wayne-Dalton for proper length cables. Attach other cable to right hand drum. Push drum against end bearing bracket and rotate drum until cable is taut. Secure drum to shaft by tightening the set screws. Cable tension must be equal on both drums on single shaft applications. On split shaft applications, apply vice grips to both shafts and secure bolts in coupling after springs are fully wound.

If top section is not installed, do so now, before winding springs. Make sure hardware is securely attached to all sections. Carefully following spring winding instructions detailed in Fig. M on Page 10, wind spring(s), using the appropriate 1/2”, 5/8” or 3/4” diameter winding rods of sufficient length.

Girt

 

 

 

Heavy Perforated Angle

 

 

 

(1-5/8 x 2-3/8” x 11 GA.)

 

 

 

Center Spring Bracket

 

 

 

(2) 3/8” x 1-1/4” Bolts To

“Y”

 

 

Secure Bracket To Angle

(< 7 ft.)

 

 

(2) 3/8” x 1-1/4” Bolts & Nuts

 

 

 

 

 

Girt

Top & Bottom

 

Fig. AA

 

 

 

Space Center Brackets 12” - 14”

 

 

 

 

 

 

Apart On Applications Requiring

Girt

 

 

Couplers

 

 

 

 

 

 

Heavy Perforated Angle

 

 

 

(1-5/8 x 2-3/8” x 11 GA.)

 

 

 

Center Spring Bracket

 

 

 

Bolt “Z” Shaped Assembly Using (4)

 

 

 

3/8” x 1-1/4” Bolts And Nuts

“Y”

 

 

(2) 3/8” x 1-1/4” Bolts To

 

 

Secure Bracket To Angle

(< 7 ft.)

 

 

 

 

(2) 3/8” x 1-1/4” Bolts & Nuts

 

 

 

 

 

Girt

Top & Bottom

 

Fig. CC

 

 

 

 

Space Center Brackets 12” - 14”

GirtApart On Applications Requiring

Couplers

Heavy Perforated Angle (1-5/8 x 2-3/8” x 11 GA.)

Center Spring Bracket

“Y”

 

 

(2) 3/8” x 1-1/4” Bolts To

 

 

Secure Bracket To Angle

(< 7 ft.)

 

 

 

 

(2) 3/8” x 1-1/4” Bolts & Nuts

 

 

 

 

 

Girt

Top & Bottom

 

Fig. BB

 

 

 

 

NOTE: Do Not Bolt (2) 3-3/4” Torsion Springs to One Center Bracket

NOTE: These Spring Mounting Techniques Are Not Supported For 800-32, 6375-164, 1100-18, 1350-28,

&800-120 Drums. These Instructions Are Also Not Applicable For 5750-120 Drums With 72” Or More High- Lift

NOTE: Maximum Spacing For Dimension “Y” is 84 in. (7 ft.) These Instructions Are Not Applicable For A Span Greater Than 84 in.

STEP 12: After spring(s) are wound, cautiously remove locking pliers from vertical tracks, while pushing downward on door to prevent it from raising unexpectedly, in case spring(s) were over wound. Carefully and slowly raise door, until one and a half sections are in the horizontal tracks. Lock door in this position using locking pliers attached to vertical tracks above bottom roller on one side and below bottom roller on other side of door.

Space the horizontal tracks 3/4” from section edge and level. Using 1-5/8” x 2’3/8” x 12 Ga. angle, fabricate back hangers and

attach them to building as shown in Fig. S on Page 13 using 3/8” bolts and nuts. Laterally brace all drop angles once proper PG. 6

Maximum Door Size 9’ x 9’ (Maximum Door Weight 210 lb.) Fig AA: Cut perforated angle (1-5/8 x 2-3/8” x 11 GA.) to Dim “Y”. Thru-bolt top and bottom of angle to each girt using (4) 3/8” x 1-1/4” bolts and nuts. Thru-bolt center bracket to perforated angle using (2) 3/8 x 1-1/4” bolts and nuts (See Fig. N-2).

Maximum Door Size 14’ x 12’ (Maximum Door Weight 400 lb.) Fig BB: Cut (2) perforated angle (1-5/8 x 2-3/8” x 11 GA.) to Dim “Y”. Thru-bolt top and bottom of each angle to each girt using (4) 3/8” x 1-1/4” bolts and nuts. Thru-bolt each center bracket to perforated angle using (2) 3/8 x 1-1/4” bolts and nuts (See Fig. N-3). Maximum Door Size 14’-2” x 12’-1” (Maximum Door Weight 800 lb.) Fig CC: Cut (2) pieces of perforated angle (1-5/8 x 2-3/8” x 11 GA.) to Dim “Y” and (2) more pieces at Dim “Y” minus 3. Bolt the angles together into a “Z” shape using (4) 3/8” x 1-1/4” bolts and nuts. Thru-bolt top and bottom of each “Z” shaped angle to each girt using (4) 3/8” x 1-1/4” bolts and nuts. Thru-bolt each center bracket to perforated angle assembly using (2) 3/8 x 1-1/4” bolts and nuts (See Fig. N-4).

NOTE: Do NOT Bolt (2) 3-3/4” Torsion Springs To ONE Center Bracket

Image 6
Contents Maintenance and Finishing Instructions Limited WarrantyContents MustStep Dish Operating ZoneSide Room B Headroom Daylight Opening Height Width ExtensionSideroom Requirements Inch TrackGraduation Sections High or Less Lateral brace all hanger anglesSpring Turn Chart Broken Cable Safety Device InstallationContact Manufacturer For Applications Not Covered Below Split Solid ShaftSingle Spring TWO SpringsTubular or 1 Piece Solid Shaft

5255, 5150, 5200, 5155 specifications

Wayne-Dalton is recognized for its high-quality garage doors, and its models 5155, 5255, 5150, and 5200 stand out for their durability, aesthetics, and advanced technology. These models are designed to cater to a variety of residential needs while ensuring reliability and performance.

The Wayne-Dalton 5155 and 5255 models are part of the brand’s premium line of insulated garage doors. The 5155 features a polystyrene core that provides excellent insulation, while the 5255 enhances energy efficiency with a polyurethane core, offering higher R-values for superior thermal performance. This makes them especially suitable for homeowners in climates with extreme temperatures, as they help maintain consistent indoor conditions.

Both models boast a beautiful design that complements any home style. The doors come in various panel designs and colors, allowing homeowners to customize their garage doors to fit their personal aesthetic. The 5155 and 5255 also feature a durable, low-maintenance exterior, crafted from high-quality materials that resist rust and corrosion, ensuring long-lasting performance.

Moving on to the Wayne-Dalton 5150 and 5200 models, these doors focus more on traditional designs while still offering modern functionality. The 5150 model features a classic raised panel design, perfect for those seeking a timeless look. On the other hand, the 5200 is known for its versatility and range of design options, allowing for greater customization.

Both models integrate advanced safety features such as pinch-resistant design, ensuring the safety of family members and pets. They are equipped with a reliable torsion spring system that offers smooth and quiet operation, making them ideal for homes where noise reduction is a priority.

Furthermore, the innovative technology employed in these Wayne-Dalton models enhances their operability and security. The doors are compatible with automatic door openers, and some models can integrate smart technology, allowing for remote access and monitoring through smartphones.

In summary, Wayne-Dalton’s 5155, 5255, 5150, and 5200 models exemplify the brand’s commitment to quality, aesthetics, and technology. Each model caters to different homeowner needs, whether it's insulation, design, or advanced features, ensuring there is a perfect garage door for every residential application.