Wayne 353601-001 specifications Battery Information, PS/BC Features

Page 2

Operating Instructions and Parts Manual

 

 

 

 

 

Battery Information

 

If battery acid

 

CHART 1 - STANDBY POWER

The system is designed to operate most

 

contacts your

 

PUMPING CAPACITY

efficiently with sealed lead acid (SLA)

eye(s), flush with cold running water

 

Amp Hours

Total Gallons

for 10 minutes and seek immediate

 

batteries. Deep cycle marine batteries

 

Per Battery

Pumped*

medical attention. If acid contacts your

 

can also be used.

 

40.0

11,000

skin or clothing, wash immediately

 

 

80.0

22,000

Sealed lead acid batteries cost slightly

with soap and water.

 

 

120.0

33,000

more, but they can last longer. Wayne

 

Never smoke or

 

 

* Assumes the sump pump is lifting water 10’

offers a 40 amp hour battery WSB1240

 

 

allow a spark or

 

 

 

and a 75 amp hour battery WSB1275.

flame in the vicinity of the battery.

SYSTEM WILL ALARM IF:

The oversize battery case (included) will

 

Avoid dropping

 

• You will hear a beeping alarm if

accommodate two 12-volt SLA batteries

 

 

metal tools on the

 

pump motor is running

or two 12-volt deep cycle marine batteries

battery posts because they may spark or

 

You will hear a continuous alarm if the

(up to a 27-frame size).

short-circuit the system or battery,

 

pump fuse on front panel is blown

Retain blue foam pad to support Wayne

causing an explosion.

 

• You will hear a continuous alarm if

 

 

sealed lead-acid batteries. Use new,

 

 

PS/BC Features

 

the battery voltage drops below 21.6

identical batteries (from the same

 

 

NOTE: The alarm must be on for the

manufacturer and of the same capacity).

POWER CIRCUITS:

 

 

mute function to activate.

When batteries wear out replace them as

• Power Supply/Battery Charger (PS/BC)

LIGHTS:

 

a set. Chart 1 illustrates the expected

monitors power availability and

Green Light indicates AC power is

performance with various battery

automatically switches to battery

 

available

 

combinations. Do not use batteries rated

operation during power outage.

Yellow Light indicates battery is

below 40 amp hours.

• Charger will run pump motor or charge

 

connected correctly

 

Be certain that the area around the

batteries when plugged into AC power

• Red Light is on when battery voltage

batteries is well ventilated. Before

• Automatically charges the batteries

 

is low or if the pump motor fuse on

servicing the batteries, blow away

• Operates on 120 VAC and 24 VDC

 

the front panel is blown

gasses by waving a piece of cardboard

(Using 2 batteries)

PUMP:

 

• The PS/BC can be left connected to

 

near the batteries.

• The pump will turn on when the

the batteries indefinitely

Dangerous

 

float switch rises. The pump motor

• The PS/BC is designed for the Wayne

 

hydrogen gas can

 

will keep running for 15 seconds

be released from batteries while

Water Systems pump only, DO NOT

 

 

after the float drops

 

charging. Sparks can ignite the gas in

Use For Any Other Purpose

 

 

 

 

 

an enclosed space. Wear safety goggles

 

 

 

 

 

when connecting batteries. Battery

 

 

 

 

 

connections should be made in a well-

 

 

 

 

 

ventilated area.

 

 

 

 

 

Working in the

 

 

 

 

 

vicinity of lead acid

(Black)

 

 

 

 

batteries can be dangerous. Before

Negative

 

 

 

making connections or servicing the

Battery Cable

 

 

PS/BC

batteries, read and follow instructions in

 

 

 

 

 

 

 

 

 

all applicable instruction manuals. To

 

 

 

 

 

reduce the risk of battery explosion,

 

 

 

 

 

follow the instructions in this manual

 

 

 

 

 

and those published by the battery

 

 

 

(Red)

 

manufacturer, as well as those of any

 

 

 

 

other equipment used in the

 

 

 

Positive Battery Cable

surrounding area.

 

 

 

 

 

An assistant should be present or close

 

 

 

 

 

enough to come to your aid in the

 

 

 

 

 

event of an emergency. Have a reliable

B

 

 

Jumper Wire

 

source of fresh water and soap nearby

A

 

 

 

in case battery acid contacts clothing,

12V

 

 

 

12V

 

 

 

 

 

 

 

skin or eyes.

Battery

 

 

 

Wear eye and clothing protection when

Battery

 

 

 

 

 

 

 

 

working around lead acid batteries.

 

 

 

 

 

Avoid touching your eyes when

 

 

 

 

 

working around lead acid batteries.

Figure 1 - Battery connection: two 12-volt batteries equals a 24-volt battery

www.waynepumps.com

 

 

 

 

 

 

 

2

 

 

 

Image 2
Contents Description Safety GuidelinesGeneral Safety Information UnpackingBattery Information PS/BC FeaturesMethod 1 Preferred Pump InstallationPump Installation MethodMethods 1 PS/BC InstallationControl Box Installation Operation MaintenanceChart 2 PS/BC Status Lights On When Action Required BatteriesTroubleshooting Chart Symptom Possible Causes Corrective ActionFor Replacement Parts, call Part No. Description Number QtyLimited Warranty Attach Your Receipt Here

353601-001 specifications

The Wayne 353601-001 is a state-of-the-art fuel dispenser that reflects a perfect blend of modern technology and user-friendly design, positioned to meet the evolving needs of the fuel retail industry. This dispenser is engineered for efficiency, reliability, and exceptional performance, making it an ideal choice for gas stations and convenience stores.

One of the standout features of the Wayne 353601-001 is its robust construction, designed to withstand the rigors of daily use in bustling service stations. The dispenser is equipped with weather-resistant components, ensuring durability and longevity in various environmental conditions. Its sleek design allows for easy maintenance, further enhancing its practicality for operators.

In terms of technology, the Wayne 353601-001 employs advanced electronic systems that facilitate precise fuel measurement and fast transaction processing. The unit incorporates advanced flow meter technology, which ensures accurate dispensing with minimal product loss. This precision not only fosters consumer trust but also enhances operational efficiency, ultimately impacting the profitability of the business.

The dispenser's interface is intuitive and user-friendly, featuring high-resolution displays that provide clear information to customers. The keypad is designed for easy navigation, and the touchscreen option allows for interactive features, including loyalty programs and promotional offers. This level of engagement can significantly enhance the customer experience, encouraging repeat business.

The Wayne 353601-001 also includes integration capabilities for various payment systems, supporting both traditional card transactions and modern contactless payment options. This versatility ensures that customers can complete their purchases conveniently, adapting to the shifts in consumer preferences towards digital payment methods.

Safety is a paramount consideration in the design of the Wayne 353601-001. It includes multiple safety features such as emergency shut-off systems, leak detection, and automatic shut-off valves that are in line with industry standards. These features not only protect the consumer but also safeguard the environment, aligning with best practices for fuel dispensing operations.

In summary, the Wayne 353601-001 stands out in the marketplace due to its combination of durability, advanced technology, user-centric design, and safety features. Whether enhancing consumer satisfaction or streamlining operational efficiency, this fuel dispenser is a reliable solution for the evolving demands of the fueling industry.