Sanyo MCO-19AIC, UV instruction manual 149

Page 59

6.When gas cylinder A is switched to B, remove gas cylinder A and replace it with new one.

Note: Be careful when handling the empty CO2 gas cylinder. Some gas may still be left in the cylinder.

ƔWhen gas cylinder B becomes empty, the line is switched to gas cylinder A again.

The MCO-21GC detects that there is no more CO2 gas in a cylinder when the CO2 density in the chamber does not increase for a while even after opening the CO2 gas valve in the Incubator. The supply line may also be switched for other reasons even though there is gas left in the cylinder: blocking or restricting of gas tube, reduction of CO2 gas pressure, or improper opening of CO2 gas cylinder. Always check the gas quantity in the cylinder before disconnecting it.

ƔUse the following procedure to manual switch the line between CO2 cylinders A and B (only when MCO-21GC is installed). This procedure shows switching the line fromCO2 cylinder B to A as an example.

1.From the Top Display, press the Left Cursor Key for 5 seconds.

1 T

2

3

4

5

6

7

e m p 3 7 . 0 o C

C O 2

5 . 0 % A

B

 

 

 

 

 

 



 

 

S t a t u s

O K

2.The CO2 gas supply line will be switched from cylinder B to A

1 T

2

3

4

5

6

7

e m p 3 7 . 0 o C

C O 2

5 . 0 %

A

B

 

 

 

 

 



 

 

S t a t u s

O K

(When the line needs to be switched from cylinder A to B, press the Right Cursor Key for 5 seconds.)

149

 

58

 

Image 59
Contents MCO-19AIC㩿UV㪀MCO-19AIC Contents Introduction Precautions for Safe Operation Unqualified personnel may cause electric shock or fire Abnormal operation may cause electric shock or fire Page Emvironmental Conditions Labels on the Incubator998 Incubator Components100 Remote alarm terminals Refer to101 Control panel and keypad102 Remote alarm terminals103 Installation Site104 Installation105 Connecting a CO2 gas cylinderWhen the MCO-21GC is not mounted When the MCO-21GC is mounted106 Preventing Contamination107 Precautions for Cultures108 Using the Unlock KeyUnlocking when power is interrupted Correct Operation109 110 Basic Operations on Control PANEL㩷111 Setting the chamber temperature and CO2 density㩷Basic Parameters 112 Setting the key lock㩷Removing the key lock㩷 113 Setting the key lock password114 115 Setting the upper limit alarm temperature116 Alarm PARAMETERS㩷117 Using the UV lamp㩷UV Lamp Parameters 118 Precautions when using the UV lampBe careful when handling the UV lamp 119 Setting the UV lamp on period120 Lighting the UV lamp for 24 hours121 Setting the date, time, and log interval122 123 Initial settings LCD/DAQ parameters124 Displaying the LOG㩷125 Transferring data126 Water Level Sensor127 Routine MaintenanceCleaning the chamber and Inner attachments 128 129 130 Filling the humidifying pan131 H2O2 Decontamination132 133 H2O2 decontamination134 OKP135 136 Precautions when handling H2O2 decontamination reagent137 ALARMS, SAFETY, and SELF-DIAGNOSISAlarms and Safety Functions for Culture Operations 138 Alarm and Safety Functions for H2O2 Decontamination139 Temperature/CO2 calibration Calibration 140 141  TroubleshootingSymptom Items to check and countermeasures 142 143 Disposing of the CO2 IncubatorGerman 144English Spanish 145French Portuguese 146Swedish 147Dutch 148 Automatic CO2 Cylinder Changeover149 150 Automatic CO2 Density CalibrationMenu, select OK, and press the Enter Key 151152     153 Stacking IncubatorsFront 155 Specifications156 Performance157 Safety check sheet

MCO-19AIC, UV specifications

The Sanyo UV, MCO-19AIC is a state-of-the-art environmental chamber designed specifically for the storage and cultivation of microorganisms, cell cultures, and other sensitive biological samples. This advanced incubator features a unique combination of technologies that ensures precise temperature and humidity control, creating optimal conditions for various laboratory applications.

One of the standout features of the Sanyo MCO-19AIC is its advanced cooling system. The unit employs a dual air jacket design that offers superior temperature stability and uniformity. With a temperature range of 0°C to 65°C, it can accommodate a wide variety of experiments and samples. This temperature control is complemented by an integrated microprocessor that continuously monitors and adjusts the conditions inside the chamber, ensuring that they remain stable even when ambient conditions fluctuate.

Another important characteristic of the Sanyo MCO-19AIC is its humidity control capability. Utilizing an advanced humidification system, this incubator can maintain relative humidity levels from 40% to 95%. This feature is particularly important in applications requiring precise moisture levels, such as cell culture or the preservation of sensitive biological specimens.

The Sanyo MCO-19AIC is also equipped with a UV sterilization system that enhances safety and cleanliness within the chamber. This system utilizes ultraviolet light to eliminate potential contaminants, ensuring that the environment remains sterile for your sensitive samples. The use of UV light minimizes the risk of cross-contamination and provides peace of mind when working with critical biological materials.

In terms of user interface, the Sanyo MCO-19AIC features a digital display with intuitive controls that allow for easy set-up and monitoring of parameters. Users can easily adjust temperature, humidity, and other settings, while real-time data is continuously displayed on the screen. Additionally, alarms and monitoring systems alert users to any potential deviations from the set conditions, maintaining the integrity of the samples housed within.

Overall, the Sanyo UV, MCO-19AIC is an indispensable tool for any modern laboratory looking to cultivate or store biological samples with precision and reliability. Its combination of advanced cooling, humidity control, and sterilization features ensures that researchers can conduct experiments with confidence, making it a preferred choice in various fields, including microbiology, biotechnology, and pharmaceuticals. With its robust design and innovative technologies, the Sanyo MCO-19AIC stands out as a leading incubator in the scientific community.