First Alert SC7010B If the CO Alarm Sounds, If the Smoke Alarm Sounds, Using the Silence Features

Page 7

IF YOUR SMOKE/CO ALARM SOUNDS, Continued

IF THE CO ALARM SOUNDS

“ALARM-MOVE TO FRESH AIR”

If you hear the CO alarm horn and the CO red light is flashing,

move everyone to a source of fresh air.

DO NOT remove the batteries!

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. In other words, when your CO Alarm sounds, you must not ignore it!

IF THE CO ALARM SIGNAL SOUNDS:

1.Operate the Test/Silence button.

2.Call your emergency services, fire department or 911. Write down the number of your local emergency service here:

____________________________________________________________

3.Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re-enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.

4.After following steps 1-3, if your CO Alarm reactivates within a 24- hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more informa- tion about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here:

____________________________________________________________

NOTE: A qualified appliance technician is defined as “a person, firm, corporation, or company that either in person or through a representative, is engaged in and responsible for the installation, testing, servicing, or replacement of heating, ventilation, air conditioning (HVAC) equipment, combustion appliances and equipment, and/or gas fireplaces or other decorative combustion equipment.”

IF THE SMOKE ALARM SOUNDS

RESPONDING TO AN ALARM

If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous situation that requires your immediate attention. NEVER ignore any alarm. Ignoring the alarm may result in injury or death.

Never remove the batteries from a battery operated Smoke/CO Alarm to stop an unwanted alarm (caused by cooking smoke, etc.). Removing batteries disables the alarm so it cannot sense smoke, and removes your protection. Instead open a window or fan the smoke away from the unit. The alarm will reset automat- ically.

If the unit alarms get everyone out of the house immediately.

WHAT TO DO IN CASE OF FIRE

Don’t panic; stay calm. Follow your family escape plan.

Get out of the house as quickly as possible. Don’t stop to get dressed or collect anything.

Feel doors with the back of your hand before opening them.

If a door is cool, open it slowly. Don’t open a hot door. Keep doors and windows closed, unless you must escape through them.

Cover your nose and mouth with a cloth (preferably damp). Take short, shallow breaths.

Meet at your planned meeting place outside your home, and do a head count to make sure everybody got out safely.

Call the Fire Department as soon as possible from outside. Give your address, then your name.

Never go back inside a burning building for any reason.

Contact your Fire Department for ideas on making your home safer.

Alarms have various limitations. See "General Limitations of Smoke/CO Alarms" for details.

USING THE SILENCE FEATURES

Never remove the batteries to quiet an unwanted alarm. Removing the batteries disables the alarm and removes your protection.

The Silence Feature is intended to temporarily silence the horn while you identify and correct the problem. Do not use the Silence Feature in emergency situations. It will not correct a CO problem or extinguish a fire.

The Silence Feature can temporarily quiet an unwanted alarm for several minutes. You can silence this Smoke/CO Alarm by pressing the Test/Silence button on the alarm cover for at least 3-5 seconds.

After the Test/Silence button is released, the Red LED blinks during the silence mode.

When the Smoke Alarm is

When the CO Alarm is

Silenced

Silenced

 

 

The Smoke Alarm will remain

The CO alarm will remain silent

silent for up to 15 minutes, then

for up to 4 minutes.

return to normal operation.

After 4 minutes, if CO levels

 

If the smoke has not cleared–or

remain potentially dangerous the

continues to increase–the device

horn will start sounding again.

will go back into alarm.

 

 

 

SILENCING THE LOW BATTERY WARNING

This Silence Feature can temporarily quiet the low battery warning “chirp” for up to 8 hours if AC power is present. Press the Test/Silence button on the Alarm cover until you hear the acknowledge “chirp”.

Once the low battery warning “chirp” silence feature is activated, the unit continues to flash the green light once a minute for 8 hours. After 8 hours, the low battery “chirp” will resume. The Alarm will continue to operate as long as AC power is supplied. However, replace the batteries as soon as possible, to maintain protection in event of a power outage.

To deactivate this feature: Press the Test/Silence button again. The unit will go into Test Mode and the low battery warning will resume (LED flashes and unit sounds “chirp” once a minute).

To silence Alarms in an interconnected series:

To silence an interconnected series of Smoke/CO Alarms, you must press the Test/Silence button on the initiating alarm (The unit with the flashing red light; the red light will be off on all other Alarms.). If you press the Test/Silence on any other Alarm, it will only silence that unit, not the whole interconnected series.

LATCHING FEATURES

Alarm Latch is activated after an Alarm is exposed to alarm levels of smoke or carbon monoxide. This feature will only work with AC power. After smoke or CO levels drop below alarm levels, the “Smoke/Power” or “CO” Red LED will begin to flash once every few seconds. It will continue to flash or “latch” until you clear it by testing the alarm.

This feature helps emergency responders, investigators, or service technicians identify which unit(s) in your home were exposed to alarm levels of smoke or carbon monoxide. This can help investigators pinpoint the source of smoke or CO.

Interconnected Alarms. Latching Alarm Indicator shows which Alarm(s) in the series were exposed to alarm levels of smoke or carbon monoxide.

The Latching Alarm Indicator stays ON until you clear it, so it can alert you to an alarm that occurred while you were away from home, even though smoke or CO present in the air has dropped below alarm levels.

Low Battery Latch is activated when the Alarm is in the "low battery condition". When this occurs, the Smoke/Power LED flashes Green On for 2 seconds/Off for 2 seconds. This feature is designed to help you identify which Alarm needs to have the battery replaced. Although, the Alarm will sound the low battery chirp approximately once every minute, sometimes during the initial stages of "low battery", the Alarm will chirp in greater intervals than one minute, sometimes up to several hours, until the battery reaches a steady low battery level. This innovative feature eliminates the frustration of waiting for and/or identifying which unit is chirping.

“SMART INTERCONNECT” FEATURE

This Alarm includes "Smart Interconnect" which enables the Alarm to be interconnected with other First Alert® and BRK Smoke, Heat, and "Smart Interconnect" CO Alarms. When smoke is detected, all Alarms will sound the smoke horn pattern. When CO is detected, "Smart Interconnect"

Alarms will sound the CO horn pattern. Alarms that do not have the "Smart Interconnect" feature will remain silent during a CO alarm.

7

Image 7
Contents USER’S Manual Table of ContentsIntroduction Recommended Placement InstallationWhere to Install this Alarm Where this Alarm should not be InstalledMounting Bracket HOW to Install this SMOKE/CO AlarmParts of this Alarm Power ConnectorSTAND-ALONE Alarm only Follow These Installation StepsInterconnected Units only To Lock the Mounting Bracket Locking FeaturesTo Lock the Battery Compartment To Unlock the Battery CompartmentWhat YOU will see and Hear with this Alarm Weekly TestingRegular Maintenance If Your SMOKE/CO Alarm SoundsSilencing the LOW Battery Warning If the CO Alarm SoundsIf the Smoke Alarm Sounds Using the Silence FeaturesHOW can I Protect MY Family from CO POISONING? What YOU Need to Know about CORegulatory Information for CO Alarms Regulatory Information for SMOKE/CO AlarmsRegulatory Information for Smoke Alarms About Smoke Alarms General Limitations of SMOKE/CO AlarmsSpecial Compliance Considerations Limited Warranty Troubleshooting Guide

SC7010B specifications

The First Alert SC7010B is a sophisticated smoke and carbon monoxide detector designed to enhance home safety through advanced technology and practical features. This dual-sensor alarm utilizes both photoelectric and ionization sensors, enabling it to rapidly detect different types of fires—ranging from smoldering flames to fast-burning fires. The combination of these two technologies ensures that the detector provides comprehensive coverage, helping to minimize false alarms, a common issue with traditional smoke detectors.

One of the standout characteristics of the SC7010B is its smart technology integration. The unit includes an intelligent sensing algorithm that differentiates between real hazards and non-threatening conditions, such as cooking smoke. This reduces the likelihood of nuisance alarms while still providing timely alerts in case of a real emergency.

Moreover, the SC7010B features a built-in carbon monoxide sensor, which is essential for detecting this colorless, odorless, and potentially lethal gas. It continuously monitors the air for high levels of carbon monoxide, providing an additional layer of safety for households. When CO levels become dangerous, the detector emits a loud alarm, alerting the occupants to evacuate and seek fresh air immediately.

In terms of usability, the First Alert SC7010B is equipped with an easy-to-read digital display that shows the levels of smoke and carbon monoxide in the environment. Additionally, the unit features a single test/silence button that allows users to easily test the system’s functionality or silence the alarm during false alarms.

A significant advantage of the SC7010B is its battery backup feature. In the event of a power outage, the unit will continue to function, ensuring constant protection. The sleek and compact design allows for easy installation on walls or ceilings, making it a versatile choice for any home layout.

Overall, the First Alert SC7010B combines advanced sensing technology with user-friendly features, making it a reliable choice for those seeking enhanced safety in their living spaces. With its ability to detect both smoke and carbon monoxide, this device is an essential addition to modern home safety protocols.