First Alert FCD4 user manual If Your CO Alarm Sounds

Page 3

Where to Install CO Alarms, Continued

In a Single-level Home:

Install at least one CO Alarm near or within each separate sleeping area.

For added protection, install an additional CO Alarm at least 20 feet (6 meters) away from the furnace or fuel burning heat source.

In a Multi-level Home:

Install at least one CO Alarm near or within each separate sleeping area.

For added protection, install at least one CO Alarm on each level of the home. If you have a basement, install that CO Alarm at the top of the basement stairs.

For added protection, install an additional CO Alarm at least 20 feet (6 meters) away from the furnace or fuel burning heat source.

This unit should receive continuous electrical power. (The battery is meant for emergency back-up only). Choose an outlet where it can’t be accidentally unplugged or switched off by children. Keep small children away from the unit. Teach them not to play with it or unplug it. Explain what the alarms mean.

WHERE CO ALARMS SHOULD NOT BE INSTALLED

DO NOT locate this CO Alarm:

In a location where it could be easily triggered when using your remote to operate your TV, VCR, etc.

In garages, kitchens, furnace rooms, or in any extremely dusty, dirty or greasy areas.

Closer than 15 feet (4.6 meters) from a furnace or other fuel burning heat source, or fuel burning appliances like a water heater.

Within 5 feet (1.5 meters) of any cooking appliance.

In extremely humid areas. This Alarm should be at least 10 feet (3 meters) from a bath or shower, sauna, humidifier, vaporizer, dishwasher, laundry room, utility room or other source of high humidity.

In areas where temperature is colder than 40˚F (4˚C) or hotter than 100˚F (38˚C). These areas include non-airconditioned crawl spaces, unfinished attics, uninsulated or poorly insulated ceilings, porches, and garages.

In turbulent air, like near ceiling fans, heat vents, air conditioners, fresh air returns, or open windows. Blowing air may prevent CO from reaching the sensors.

In direct sunlight.

In outlets covered by curtains or other obstruction.

This CO Alarm is designed for use inside a single-family home or apartment. It is not meant to be used in common lobbies, hallways, or basements of multi-family buildings unless working CO Alarms are also installed in each family living unit. CO Alarms in common areas may not be heard from inside individual family living units.

This CO Alarm alone is not a suitable substitute for complete detection systems in places which house many people, like hotels or dormitories, unless a CO Alarm is also placed in each unit.

DO NOT use this CO Alarm in warehouses, industrial or commercial buildings, special-purpose non-residential buildings, RVs, boats, or airplanes. This CO Alarm is specifically designed for residential use, and may not provide adequate protection in non-residential applications.

HOW TO INSTALL YOUR CO ALARM

IMPORTANT! Read all instructions before using this product.

Quick reference:

• Install the 9V battery to activate the battery back-up.

• Plug the Alarm into a standard 120V unswitched outlet.

• Test the CO Alarm.

ACTIVATE THE BATTERY BACK-UP

1. Open the battery compartment on the back of the Alarm.

2. Connect the battery to the battery contacts, making sure it cannot shake loose.

3. Close the battery compartment completely.

The battery back-up is designed to provide emergency power to the CO Alarm for 7 days. Actual back-up time depends on the strength (freshness) of the battery. The battery back-up will not work unless a good battery is properly installed.

PLUG THE ALARM INTO AN OUTLET

This CO Alarm should receive continuous electrical power. The battery is meant for emergency back-up only. Do not plug this Alarm into an outlet controlled by a dimmer or switch.

1.Plug the unit into a standard UNSWITCHED 120V AC outlet. The unit should be located where it can wake you if it alarms at night.

2.Make sure the POWER/ALARM light shines continuously when you plug it in.

3.Test by pressing the Test/Silence/Scroll button firmly until the unit sounds: 4 beeps, pause, 4 beeps. During testing, the POWER/ALARM light will flash and “888” will appear briefly on the Display. This is normal.

PREPARE YOUR ALARM LABELS

Find the pair of self-adhesive labels included with this CO Alarm.

On each label write in the phone number of your emergency responder (like 911) and a qualified appliance technician.

Place one label near the CO Alarm, and the other label in the “fresh air” location you plan to go if the alarm sounds.

NOTE: A qualified appliance technician is defined as “a person, firm, corpora- tion, or company that either in person or through a representative, is engaged in and responsible for the installation, testing, servicing, or replacement of heating, ventilation, air conditioning (HVAC) equipment, combustion appli- ances and equipment, and/or gas fireplaces or other decorative combustion equipment.”

IF YOUR CO ALARM SOUNDS

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. When your CO Alarm sounds, you must not ignore it!

IF THE ALARM SIGNAL SOUNDS:

1.Operate the Test/Silence button.

2.Call your emergency services, fire department or 911. Write down the number of your local emergency service here:

__________________________________________________________________

3.Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re- enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.

4.After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to inves- tigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here:

_________________________________________________________________

“ALARM-MOVE TO FRESH AIR”

If you hear the alarm horn and the red light is flashing, move everyone to a source of fresh air.

DO NOT unplug the CO Alarm!

Alarms have various limitations. See "General Limitations of CO Alarms" for details.

Continued...

3

Image 3
Contents USER’S Manual Table of ContentsHOW Your CO Alarm Works IntroductionUsing the Remote Control TEST/SILENCE Feature InstallationUnderstanding Your CO Alarm Where to Install CO AlarmsIf Your CO Alarm Sounds Testing and Maintenance Underwriters Laboratories INC. UL2034 What YOU Need to Know about COUL2034 Information Limited Warranty General Limitations of CO AlarmsFrequently Asked Questions How to Obtain Warranty Service

FCD4 specifications

The First Alert FCD4 is a highly regarded combination smoke and carbon monoxide detector, designed to enhance home safety through advanced technology and innovative features. This unit is particularly notable for its dual functionality, providing reliable detection for both smoke and carbon monoxide—two of the most significant threats to home safety.

One of the main features of the First Alert FCD4 is its photoelectric smoke detection technology. This system is designed to minimize false alarms often triggered by cooking smoke or shower steam, making it a suitable choice for kitchens and bathrooms. Photoelectric sensors detect larger smoke particles produced by smoldering fires, offering a fast response to potential hazards while reducing unnecessary disturbances.

The FCD4 is equipped with an electrochemical CO sensor, which is the most effective technology for detecting carbon monoxide. This feature allows the device to monitor CO levels continuously, providing alerts before harmful levels are reached. The combination of smoke and CO detection in one unit simplifies installation and maximizes safety by ensuring that homeowners are alerted to multiple dangers with a single device.

Another characteristic of the First Alert FCD4 is its battery operation, which enhances its reliability. The unit comes with a 10-year battery life, eliminating the need for frequent battery changes. Additionally, it features a convenient battery lockout system that helps prevent the device from being accidentally powered on without a battery in place, enhancing safety during installation.

A notable convenience feature of the FCD4 is its easy-to-read LED display that indicates the status of the unit, including whether it is in alarm mode or when the battery needs to be replaced. The device also includes an easy-access testing and silencing button, which allows homeowners to test its functionality quickly and silence alarms without removing the batteries.

The First Alert FCD4 meets safety standards set by Underwriters Laboratories, ensuring it has been rigorously tested for reliability and effectiveness. It stands out as a comprehensive safety solution, combining modern technology with user-friendly features and a commitment to protecting families from the dangers of smoke and carbon monoxide.