Sierra Monitor Corporation Gas Detector manual Sentry Modbus I/O Memory Map

Page 14

Sentry MODBUS I/O Memory Map

Modbus Address

Parameter

 

Units

FIX EGU

40356

Sensor 5 Input Value - Multiplex 0

0 - 6553.5

40357

Sensor 5 Input Value - Multiplex 1

0 - 6553.5

40358

Sensor 5 Input Value - Multiplex 2

0 - 6553.5

40359

Sensor 5 Input Value - Multiplex 3

0 - 6553.5

40360

Sensor 5 Input Value - Multiplex 4

0 - 6553.5

40361

Sensor 5 Input Value - Multiplex 5

0 - 6553.5

40362

Sensor 5 Input Value - Multiplex 6

0 - 6553.5

40363

Sensor 5 Input Value - Multiplex 7

0 - 6553.5

40364

Sensor 5 Calibration Due Days

 

40365

Sensor 6 High Alarm Time Month

 

40366

Sensor 6 High Alarm Time Day

 

40367

Sensor 6 High Alarm Time Hr

 

40368

Sensor 6 High Alarm Time Min

 

40369

Sensor 6 Low Alarm Time

Month

 

40370

Sensor 6 Low Alarm Time

Day

 

40371

Sensor 6 Low Alarm Time

Hr

 

40372

Sensor 6 Low Alarm Time

Min

 

40373

Sensor 6 Calibration Time Month

 

40374

Sensor 6 Calibration Time Day

 

40375

Sensor 6 Calibration Time Hr

 

40376

Sensor 6 Calibration Time Min

 

40377

Sensor 6 High Conc. Time Month

 

40378

Sensor 6 High Conc. Time Day

 

40379

Sensor 6 High Conc. Time Hr

 

40380

Sensor 6 High Conc. Time Min

 

40381

Sensor 6 Low Conc. Time

Month

 

40382

Sensor 6 Low Conc. Time

Day

 

40383

Sensor 6 Low Conc. Time

Hr

 

40384

Sensor 6 Low Conc. Time

Min

 

40385

Sensor 6 Trouble Time

Month

 

40386

Sensor 6 Trouble Time

Day

 

40387

Sensor 6 Trouble Time

Hr

 

40388

Sensor 6 Trouble Time

Min

 

40389

Sensor 6 Input Value - Multiplex 0

0 - 6553.5

40390

Sensor 6 Input Value - Multiplex 1

0 - 6553.5

40391

Sensor 6 Input Value - Multiplex 2

0 - 6553.5

40392

Sensor 6 Input Value - Multiplex 3

0 - 6553.5

40393

Sensor 6 Input Value - Multiplex 4

0 - 6553.5

40394

Sensor 6 Input Value - Multiplex 5

0 - 6553.5

40395

Sensor 6 Input Value - Multiplex 6

0 - 6553.5

40396

Sensor 6 Input Value - Multiplex 7

0 - 6553.5

40397

Sensor 6 Calibration Due Days

 

March 4, 2005

Page: 13

Image 14
Contents Sentry Controller Modbus Memory Map Sentry Controller Modbus Memory Map Detail Discrete Read Only Parameters UnitsModbus Address FIX EGU Sentry Modbus I/O Memory Map Sentry Modbus I/O Memory Map Sentry Modbus I/O Memory Map Sentry Modbus I/O Memory Map Analog Process Variables Sentry Modbus I/O Memory Map Sentry Modbus I/O Memory Map Sentry Modbus I/O Memory Map Sentry Modbus I/O Memory Map Sentry Modbus I/O Memory Map Sentry Modbus I/O Memory Map Sentry Modbus I/O Memory Map H2S/CH4/Oxy/CO Read/Write Parameters High Alarm LimitsLow Alarm Limits Sentry Modbus I/O Memory Map Control Bits

Gas Detector specifications

Sierra Monitor Corporation, a leader in environmental monitoring and gas detection systems, has developed an innovative range of gas detectors tailored for industrial applications. These systems are designed to provide reliable, real-time monitoring of hazardous gases, ensuring the safety of personnel and the environment.

One of the standout features of Sierra Monitor's gas detectors is their advanced sensor technology. The devices are equipped with a variety of sensors that can detect a range of gases including methane, hydrogen sulfide, and carbon monoxide. These sensors utilize industry-leading electrochemical and catalytic bead technologies to deliver accurate and responsive measurements, minimizing the risk of false alarms.

In addition to robust sensor capabilities, Sierra Monitor gas detectors feature intelligent monitoring solutions that facilitate seamless integration with existing facility management systems. The detectors can communicate via various protocols such as Modbus, Ethernet/IP, and BACnet, allowing for real-time data transmission and centralized monitoring. This ensures that facility managers can respond swiftly to any detected gas anomalies, significantly improving workplace safety.

The design of the gas detectors prioritizes durability and flexibility. Many models come with rugged housings that can withstand harsh environmental conditions, making them perfect for use in challenging industrial settings. Additionally, the detectors are often equipped with user-friendly interfaces, allowing for straightforward calibration and maintenance.

Sierra Monitor also places a strong emphasis on user experience. Their gas detectors often include features such as audible alarms, LED indicators, and remote monitoring capabilities. These features help ensure that any hazardous conditions are immediately communicated to personnel, thereby promoting a proactive safety culture.

Moreover, the corporation focuses on innovation in power solutions, offering models with low power consumption and options for battery operation. This allows for deployment in remote locations where power is limited, ensuring essential gas monitoring without interruptions.

Overall, Sierra Monitor Corporation's gas detectors stand out for their combination of cutting-edge technology, user-friendly design, and robust safety features, making them an invaluable asset for industries concerned about gas hazards. By harnessing the latest advancements in sensor technology and connectivity, Sierra Monitor ensures that facilities are equipped not just to detect, but to effectively manage gas-related risks.