Children should be warned of the dangers of CO poisoning and instructed never to touch, or inter- fere with the CO Alarm. Do not allow small children to press the test/hush button as they could be subjected to excessive noise when the unit alarms.

B15404-R0-261EN-UC-ENG 31/5/07 2:01 PM Page 26

(7)Never use a gas cooker or a barbecue for home heating.

(8

(9)Leaving windows or doors slightly open (even a few inches) will significantly reduce the risk of high levels of CO occurring. The high levels of draught-proofing in modern houses reduces ventilation and can allow dangerous gases to build up.

(10)Install CO Alarms in all the areas recommended in this leaflet.

(11)Recognise that CO poisoning may be the cause when family members suffer from “flu-like” symp- toms when at home but feel better when they are away for extended periods.

 

 

9. TECHNICAL SPECIFICATION

 

 

Operating Voltage

: 230±10% VAC, 50Hz

Power

:

1 Watt, (60 mA)

Power on Indicator

:

Green Light on

Sensor

:

Electrochemical Sensor

CO Sensitivity

: Meets BS EN 50291: 2001.

 

 

Unit operates as per Table B above.

Electrical Safety

:

Complies with relevant sections of EN 60335-1: 1994

24

Image 26
Contents Digital Display Ei261DEN onlyContents Read this First What to do when the alarm sounds What is Carbon Monoxide ? Carbon Monoxide the Silent KillerSymptoms of Carbon Monoxide Poisoning High levels of CO in a house can be caused byInhalation Time approx and Symptoms Developed Table a Effects of Carbon Monoxide PoisoningIf your CO Alarm sounds follow the instructions on What happens when your CO Alarm detects Carbon Monoxide ?Table B CO Alarm Response Ppm Off 50ppmEi261-DEN Only Never Ignore the AlarmCO Alarm Memory Where to Place CO Alarms Unsuitable Locations B15404-R0-261EN-UC-ENG 31/5/07 201 PM Location in room with a fuel burning appliance Location in rooms with sloped Installing Your Carbon Monoxide Alarms Installation Procedure Surface Wiring Interconnecting Ei Electronics Carbon Monoxide Alarms Interconnect Wiring Diagram CO Alarms and Smoke Alarms should not be InterconnectedTesting Your CO Alarm How to distinguish between CO Alarm and Smoke Alarm Warnings Sensor Module Replacement Maintaining Your CO AlarmHow to disconnect and remove the alarm Limitations of CO Alarms B15404-R0-261EN-UC-ENG 31/5/07 201 PM HOW to Protect Your Family Technical Specification Sensing CO B15404-R0-261EN-UC-ENG 31/5/07 201 PM Getting the CO Alarm Serviced Five Year GuaranteeAlarm Beeps and Amber Light Flashes Every 40 Seconds TroubleshootingAlarm does not Work with the Test Button Alarm Beeps Every 40 Seconds without amber light flashingTEST/HUSH Button does not Silence Alarms Ei Electronics

Ei 261DEN, Ei 261EN specifications

Ei Electronics is renowned for its innovation in the fire detection and alarm industry, and among its impressive product offerings, the Ei 261DEN and Ei 261EN smoke alarms stand out for their reliability and advanced features. Both models are designed to provide maximum safety and ease of use in residential and commercial settings.

The Ei 261DEN is equipped with a high-performance optical smoke sensor that detects a broad range of smoke particles, making it particularly effective at sensing smoldering fires. Its intelligent design allows it to differentiate between genuine fire situations and false alarms, such as from cooking smoke or steam. This capability reduces nuisance alarms, ensuring that users remain alert but not overly disturbed by non-threatening activations.

On the other hand, the Ei 261EN offers a similar level of performance with slight variations in features tailored to different environments. This model also utilizes a reliable optical smoke sensor but includes enhanced connectivity options for integration with other alarm systems. The Ei 261EN is particularly suited for larger homes or commercial spaces where multiple interconnected alarms can provide a comprehensive safety network.

One of the prominent characteristics of both models is their user-friendly interface. Each alarm is designed with an easy-to-use test button that allows users to check the functionality of the unit quickly. Additionally, these devices feature a low battery warning system that alerts users when it’s time to replace the battery, ensuring that the alarm remains operational at all times.

Another critical feature is the sealed battery technology found in these alarms. The Ei 261DEN and Ei 261EN come with long-lasting batteries that can power the alarm for up to ten years, eliminating the need for frequent battery changes. This design enhances user convenience and ensures uninterrupted protection.

In terms of build quality, both models are constructed to withstand harsh conditions, making them suitable for various installations. Their compact design and modern aesthetics ensure they can blend seamlessly into any environment without compromising on functionality.

In summary, the Ei Electronics Ei 261DEN and Ei 261EN smoke alarms embody advanced fire detection technology, user-centric design, and robust performance. Their features make them ideal for ensuring safety in both homes and workplaces, highlighting Ei Electronics' commitment to innovation and reliability in safety solutions.