Cat. No. SC1000B
APPLICATION
BRK Electronics Model SC1000B is a 9V battery operated single station Combination Smoke & Carbon Monoxide (CO) Alarm specifically designed for residential and institutional applications including single family homes, multifamily homes, sleeping rooms of hospitals, hotels, motels, dormitories, and other mixed occupancy dwellings as defined in standard NFPA 101. Model SC1000B has been fully tested and complies with Underwriters Laboratories, Inc. Single and Multiple Station Carbon Monoxide Detectors UL 2034, with Underwriters Laboratories, Inc. Single and Multiple Station Smoke Alarms UL 217, the California State Fire Marshal, and with model building codes published by ICBO, SBCCI, BOCA and CABO.
Model SC1000B combines Smoke Alarm and CO Alarm technologies in one unit. As a Carbon Monoxide alarm, Model SC1000B measures CO levels in the air and alerts the occupant(s) to a potentially dangerous
As a Smoke Alarm, Model SC1000B provides early warning of fire when smoke reaches its Ionization Sensor Chamber. The sensor consists of two electrically charged plates and a source of Americium 241 to ionize the air molecules in the space between the plates. As particles of combustion enter the ionization chamber, they collide and combine with ionized air molecules resulting in a decrease in current between the two plates. Electronic circuitry monitors the change in current. When smoke inside the chamber reaches a threshold level the unit triggers an audible alarm.
Model SC1000B features four colored indicator lights and an 85dB alarm horn for alarm notification. A flashing green LED indicates the unit is receiving power; flashes yellow when battery is low. For easy alarm identification “Flame” and “CO” LED icons flash red respectively when the unit has detected enough smoke and/or CO to trigger an alarm. A flashing yellow LED indicates the unit needs to be serviced or replaced. Different horn patterns make it easy to determine which alarm, smoke or CO, is sounding. It also has a silence feature to temporarily quiet the alarm horn.
Refer to NFPA 72, NFPA101, and with model building codes published by ICBO, SBCCI, BOCA, and CABO for information on the proper location, placement, of Smoke Alarms. The Consumer Product Safety Commission (CPSC) recommends the use of at least one CO Alarm per household, located near the sleeping area. For added protection, install additional CO Alarms in each separate bedroom, and on every level of the home. Also, refer to Model SC1000B - User’s Manual for more information on the proper location, placement, and installation of this Combination Smoke and Carbon Monoxide Alarm.
Mounting hardware and 9V alkaline battery are included with the unit.
SMOKE & CARBON MONOXIDE ALARM
9V BATTERY POWERED
1.Permanently installed smoke and CO sensors meeting sensitivity requirements of Underwriters Laboratories, Inc. UL 2034 and UL 217.
2.The unit shall be capable of self-restoring.
3.A silence button that silences the alarm while the occupant(s) respond. If significant levels of Smoke an/or CO are present after the initial silenced period, or if they continue to rise, the detector will alarm again.
4.The unit shall be powered by a single 9V battery (included).
5.A flashing green LED to indicate the unit is receiving power; flashes yellow when battery is low. “Flame” and “CO” LED icons that flash respectively when the unit has detected enough smoke and/or CO to trigger an alarm for easy alarm identification. A flashing yellow LED to indicate the unit needs to be serviced or replaced.
6.Different horn patterns to identify which alarm, smoke or CO, is in alarm.
7.A manual test button to test all functions by electronically simulating the presence of smoke and CO.
8.A solid state piezo alarm horn rated at 85dB at 10ft.
9.The unit shall be capable of operating between 40F and 100F
10.The unit shall be capable of surface mount on walls and ceilings.
11.The unit shall be listed by Underwriters Laboratories, Inc. Single and Multiple Station Carbon Monoxide Detectors UL 2034 and Multiple Station Carbon Monoxide Detectors UL 2034, Underwriter’s Laboratories Single and Multiple Station Smoke Alarm UL 217, and the State of California Fire Marshal.
12.The unit shall meet the requirements NFPA72, NFPA101, ICBO, BOCA, SBCCI, and CABO.
13.A five year manufacturers limited warranty.
TECHNICAL SPECIFICATIONS
Alarm Circuit | 100% Solid State |
Operating Voltage | 9V DC |
Operating Ambient Temp. Range | 40°F(4°C) to 100°F(38°C) |
Operating Humidity Range | 30% to 70% RH |
Alarm Horn Rating | 85dB at 10Ft. |
Alarm Reset | Automatic when Smoke and/or CO clears |
Single Test/Silence Button | Tests all functions by electronically simulating the |
| presence of smoke and CO. |
| Silences the alarm while the occupant(s) |
| respond. If significant levels of smoke and/or |
| CO are present after the initial silenced |
| period, or if they continue to rise, the alarm |
| will alarm again. |
Alarm Status Indicators |
|
Battery Status Indicator | Flashes green when unit is receiving power. |
| Flashes yellow when battery is low. |
Service Status Indicator | Flashes yellow when the unit needs |
| service or replacement. |
Smoke and CO Alarm Status Indicator | ”Flame” and “CO” LED icons flash red |
| respectively when the unit has detected |
| enough CO and/or smoke to trigger an |
| alarm. |
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS
The Combination Smoke and Carbon Monoxide (CO) Alarm shall be BRK Electronics Cat. No. SC1000B or approved equal and shall provide, at a minimum, the following features and functions.
Unit Dimensions | 5 5⁄8"Dia x 1 13⁄16"H (w/ bracket) |
Unit Weight | .7 lbs. |
NAED # | 85614 |
Units Per Case | 3 units |
MANUFACTURED BY: | DISTRIBUTED BY: |
BRK® Electronics
3901 Liberty Street Road
Aurora, IL
©1997 BRK Brands, Inc.
Printed in USA
FOR TECHNICAL HELP OR REPRESENTATIVE NEAREST YOU PHONE
CM2019