SPECIFICATIONS
Low Dew Point Control Level (“MORE DRY” or 7 bars on display) | 40°F |
|
|
High Dew Point Control Level (“LESS DRY” or 1 bar on display) | 65°F |
|
|
Temperature Sensor Range | 40°F to 100°F |
|
|
Relative Humidity Sensor Range | 30% to 100% |
|
|
Temperature Storage Conditions | |
|
|
Relative Humidity Storage Conditions | 0 to 100% |
|
|
Supply Voltage (DC from Central Dehumidifier Control Board) | 12 VDC |
|
|
LIVING SPACE CONTROL INSTALLATION INSTRUCTIONS
STEP 1. CHOOSE A LOCATION TO MOUNT THE CONTROL
The Model 70 Living Space Control contains its own sensors that override the Aprilaire Central Dehumidifier main control sensors when connected and enabled. Therefore, the control should be located in an area (living room, master bedroom, etc.) where the homeowner wants to monitor and control moisture levels at a convenient location.
MOUNT CONTROL…
•Approximately 5 feet off the floor (refer to local codes for compliance with the Americans with Disabilities Act).
•On an interior wall where the humidity is representative of the home being dehumidified.
•At least 18 inches away from an outside wall.
DO NOT MOUNT CONTROL…
•Behind doors, in corners or other dead air spaces.
•In direct sunlight, near lamps or other sources of heat.
•On an outside wall or any wall exposed to an unconditioned space (i.e. garage).
•In the airflow path of a supply register or near outside doors.
•On a wall where concealed pipes or ductwork will affect the control temperature and relative humidity accuracy.
STEP 2. DISASSEMBLE THE CONTROL
Carefully remove the front cover from the backing plate. See Figure 1.
Figure 1 – Disassemble the Control
|
| T |
|
| PAR |
| A | |
L |
| |
L |
|
|
PU |
|
|
BACKING PLATE
FRONT COVER