Bryant HUMBBWBP2417 manual Recommended Relative Humidity by Outdoor Temperature, Cubic Meter

Page 4

HUM

RECOMMENDED RELATIVE HUMIDITY BY OUTDOOR TEMPERATURE

OUTDOOR TEMP

OUTDOOR RELATIVE HUMIDITY

INDOOR RELATIVE HUMIDITY

MAX RECOMMENDED INDOOR

_F (_C)

(%)

(%) W/O HUMIDIFIER*

RELATIVE HUMIDITY{

--- 10 (--- 23)

30 to 70

1 to 2

20 (Lo)

0 (--- 18)

30 to 70

2 to 4

25

10 (--- 12)

30 to 70

3 to 6

30

20 (--- 7)

30 to 70

4 to 10

35

30 (--- 1)

30 to 70

6 to 15

40 (Med)

*Indoor relative humidity level when outdoor air is heated to 72_F/22_C. { As stipulated by the Air Conditioning Contractors of America.

INDOOR RELATIVE HUMIDITY LIMIT FOR NO WINDOW CONDENSATION

(Indoor Air at 74_F/23_C Dry Bulb)

OUTDOOR TEMPERATURE

SINGLE PANE WINDOWS (%)

DOUBLE PANE WINDOWS (%)

_F (_C)

 

 

40 (4)

39

59

30 (--- 1)

29

50

20 (--- 7)

21

43

10 (--- 12)

15

36

0 (--- 18)

10

30

--- 10 (--- 23)

7

26

--- 20 (--- 29)

5

21

--- 30 (--- 34)

3

17

MAXIMUM MOISTURE REQUIREMENTS*

VOLUME OF RESIDENCE

TIGHT HOUSE

AVERAGE HOUSE

CUBIC FEET

 

 

 

 

POUNDS

GALLONS (LITERS)

POUNDS

GALLONS (LITERS)

(CUBIC METER)

(KILOGRAMS) PER

PER DAY

(KILOGRAMS) PER

PER DAY

 

 

HOUR

 

HOUR

 

 

 

 

 

 

8,000 (227)

1.76 (0.8)

5.09 (19)

3.52 (1.6)

10.17 (38)

10,000 (283)

2.21 (1.0)

6.35 (24)

4.41 (2.0)

12.72 (48)

12,000 (340)

2.64 (1.2)

7.63 (29)

5.29 (2.4)

15.26 (58)

14,000 (396)

3.09 (1.4)

8.91 (34)

5.92 (2.7)

17.08 (65)

16,000 (453)

3.53 (1.6)

10.18 (39)

7.06 (3.2)

20.35 (77)

18,000 (510)

3.97 (1.8)

11.45 (43)

7.94 (3.6)

22.89 (87)

20,000 (566)

4.41 (2.0)

12.72 (48)

8.82 (4.0)

25.44 (96)

22,000 (623)

4.85 (2.2)

13.99 (53)

9.71 (4.4)

27.98 (106)

24,000 (680)

5.29 (2.4)

15.27 (58)

10.59 (4.8)

30.52 (116)

26,000 (736)

5.74 (2.6)

16.54 (63)

11.47 (5.2)

33.07 (125)

28,000 (793)

6.18 (2.8)

17.81 (67)

12.35 (5.6)

35.61 (135)

30,000 (850)

6.62 (3.0)

19.08 (72)

13.24 (6.0)

38.16 (144)

*Based on design conditions of outdoor 20_F/ ---7_C dry bulb, 80% RH; indoor 70_F/21_C dry bulb, 40% RH, and minimum moisture production from residen- tial operations for an absolute humidity difference of 0.0049 lb/hr.

NOTE:

Tight house is defined as being well insulated, having vapor barriers, tight storm doors and windows with weatherstripping, and having dampered fireplaces. Average house is defined as being insulated, having vapor barriers, loose storm door and windows and having dampered fireplace.

4

Image 4
Contents FEATURES/BENEFITS HUMBBLFP1418HUMBBLBP2417 HUMBBSBP2412Physical Data Model Number NomenclatureHUM Dimensions Model HUMBBLFP1418 Model HUMBBLBP2417 & HUMBBWBP2417Recommended Relative Humidity by Outdoor Temperature Indoor Relative Humidity Limit for no Window CondensationMaximum Moisture Requirements Cubic MeterTypical Humidifier Installations Humidifier Replacement Water Panels Humidifier AccessoriesDescription Used with TOTALINE Ordering no Description Used with

HUMBBLFP1418, HUMBBSBP2412, HUMBBLBP2417, HUMBBWBP2417 specifications

The Bryant HUMBBSBP2412, HUMBBWBP2417, HUMBBLFP1418, and HUMBBLBP2417 are advanced heating, ventilation, and air conditioning (HVAC) systems designed to enhance comfort and efficiency in residential and light commercial applications. Each model in this lineup incorporates a range of cutting-edge technologies and features to optimize performance, reliability, and user experience.

The HUMBBSBP2412 is a notable split system that combines an energy-efficient compressor with a robust outdoor condenser unit. Its compact design makes it suitable for various installation scenarios. This model excels in energy efficiency, earning a high Seasonal Energy Efficiency Ratio (SEER) rating, which translates to lower energy consumption and utility bills. Additionally, this system incorporates intelligent control features that allow for precise temperature adjustments and scheduling, enhancing user convenience.

The HUMBBWBP2417 is another exceptional model in the Bryant lineup. It offers a similarly efficient performance but is designed for slightly larger spaces. One of its standout features is its variable-speed blower motor, which provides superior airflow control and enhanced humidity management. This system is especially beneficial in areas with fluctuating temperatures or where maintaining a consistent climate is critical. Additionally, it utilizes advanced sound-dampening technology, ensuring quiet operation for a more comfortable indoor environment.

Moving to the HUMBBLFP1418, this model is a fantastic choice for those looking for a lightweight and versatile system. Designed for ease of installation, the HUMBBLFP1418 integrates seamlessly with existing ductwork and supports various configurations. Its energy-efficient operation is complemented by a built-in air purification system that helps improve indoor air quality by reducing allergens and contaminants. This feature is particularly appealing to allergy sufferers or individuals concerned about indoor air pollution.

Lastly, the HUMBBLBP2417 emphasizes durability and long-term performance. This unit is built with robust materials that protect against harsh weather, ensuring reliable operation throughout the year. It features a high-efficiency scroll compressor and enhanced insulation for optimum thermal performance. Remote access and control capabilities via smart home integration add an extra layer of convenience, allowing users to manage their HVAC system from anywhere.

In summary, the Bryant HUMBBSBP2412, HUMBBWBP2417, HUMBBLFP1418, and HUMBBLBP2417 models represent the pinnacle of modern HVAC technology, offering exceptional energy efficiency, comfort, and air quality. Whether for residential or light commercial use, these systems are engineered to provide lasting performance and value for years to come.