Maxon Telecom 700, 850, 550, 300, 100 Spark ignitor SI-1/2, Filter Elements FLT- Indi, 3 15 E m 7/08

Page 10

Low temperature burners - INDITHERM®

1 - 2.3 - 15 E - m - 7/08

Spark ignitor - SI-1/2

The spark ignitor is standard included with the burner. It is advised to keep at least one additional spark ignitor available as a spare item for maintenance.

This spark ignitor can be mounted directly onto the burner spark ignitor connection port.

To be used on all burner sizes. See table below for mounting position C depending on burner size.

1)1/2” NPT

Dimensions in mm unless stated otherwise

burner size

A

B

C

D

Ø E

 

 

 

 

 

 

100

165

140

33

5

14

 

 

 

 

 

 

300

165

140

37

5

14

 

 

 

 

 

 

550-850

165

140

31

5

14

 

 

 

 

 

 

1100-1800

165

140

33

5

14

 

 

 

 

 

 

Filter Elements - FLT- INDI

Replacement elements for the optional INDITHERM® burners combustion air filters.

Available in 4 types to cover all burner sizes.

„FLT-INDI-1 for burner sizes 100 and 300

„FLT-INDI-2 for burner size 550

„FLT-INDI-3 for burner sizes 700-850-1100-1500

„FLT-INDI-4 for burner size 1800

w w w . m a x o n c o r p . c o m

combustion systems for industry

MAXON reserves the right to alter specifications and data without prior notice. © 2008 Copyright Maxon Corporation. All rights reserved.

Image 10
Contents Low temperature burners Inditherm Specifications of Inditherm burners3 6 E m 7/08 Materials of construction 3 7 E m 7/08Available Inditherm burner versions and options Selection criteriaApplication details 3 8 E m 7/08Burner discharge sleeve Fuels3 9 E m 7/08 Minimum capacities Process temperatureMaximum capacities Preheated airGas pipe train design Low temperature burners Inditherm Flame supervisionFlame development Process back pressuresInditherm with standard discharge sleeve all sizes Dimensions3 12 E m 7/08 Inditherm with high temperature discharge sleeve all sizes 3 13 E m 7/08Adjustable orifice for pilot burner ADJ-ORF 3 14 E m 7/08Filter Elements FLT- Indi Spark ignitor SI-1/23 15 E m 7/08 Gaskets GSK- Indi 3 16 E m 7/08Installation instructions Application requirements3 18 E m 7/08 Low temperature burners Inditherm Burner mounting flange 3 19 E m 7/083 20 E m 7/08 Start-up instructions for Inditherm burners 3 21 E m 7/08Visual inspections Maintenance and inspectionSafety requirements Recommended spare parts

1100, 100, 1500, 700, 550 specifications

Maxon Telecom 1800, 850, 700, 1500, 300 represents a series of advanced telecommunications infrastructure solutions that cater to diverse connectivity needs. With its robust features and modern technologies, Maxon Telecom is paving the way for enhanced communication in various sectors, including mobile networks, satellite services, and broadband applications.

One of the main features of the Maxon Telecom series is its multi-band capabilities. Supporting frequencies such as 1800 MHz, 850 MHz, and 700 MHz, these systems enable operators to provide seamless coverage and improved data speeds across urban and rural landscapes. The 1500 MHz band is particularly advantageous for applications requiring high-capacity data throughput, making it suitable for dense population areas. The inclusion of the 300 MHz band enhances the offering by facilitating broader network coverage, crucial for emerging IoT technologies.

In terms of technology, Maxon Telecom utilizes state-of-the-art amplification and filtering systems that enhance signal clarity and strength. This approach minimizes dropouts and provides a consistent user experience. The incorporation of advanced digital signal processing techniques allows for better handling of high-volume data traffic, ensuring that users can stay connected even during peak usage times.

The design characteristics of the Maxon Telecom systems focus on both reliability and efficiency. Built to withstand various environmental conditions, these units come with rugged enclosures that protect against heat, moisture, and dust. Moreover, energy-efficient components ensure that the systems consume less power while delivering high performance, aligning with global sustainability goals.

Scalability is another key trait of the Maxon Telecom series. Operators can easily integrate these systems into existing networks, allowing for seamless upgrades without significant infrastructure changes. This modular approach also enables customization based on specific regional requirements, ensuring that the solutions can adapt as technology evolves.

Overall, Maxon Telecom 1800, 850, 700, 1500, 300 stands out as a comprehensive communication solution suitable for today's digital landscape. Its blend of multi-band support, advanced technology, and robust design makes it an ideal choice for telecom operators aiming to enhance their service offerings and meet the ever-increasing demands for reliable connectivity. Through continuous innovation, Maxon Telecom is well-positioned to address the challenges of modern communication needs.