Table 1 - Nozzle Capacities

Rated gph @

Pressure - Pounds per

100 psig

square inch

 

 

 

 

140

150

1.75

2.07

2.14

2.00

2.37

2.45

2.25

2.66

2.74

2.50

2.96

3.06

2.75

3.24

3.37

3.00

3.55

3.68

3.50

4.13

4.29

4.00

4.70

4.90

4.50

5.30

5.51

5.00

5.90

6.13

5.50

6.50

6.74

6.00

7.10

7.33

6.50

7.65

7.96

‰Verify air tube

yThe information in this section may be disregarded if the air tube is supplied by the appliance manufacturer.

yTwo tube arrangements are available –

CF500 1.75 to 5.50 GPH

CF800 Tube A — 3.00 to 7.00 GPH

Tube B — 5.00 to 8.00 GPH

yMaximum firing capacity depends on the firebox pressure. Use Table 2 to verify the correct air tube type for the fir- ing rate required. Use Tube B only when Tube A cannot provide the firing rate required.

ySee Figure 2 to verify the correct air tube length and air tube combination code.

‰Verify firing rate

yRefer to appliance manufacturer’s instructions (if available) for firing rate and nozzle selection. Otherwise, the maximum recommended firing rate for the burner depends on the length of the firing chamber and the distance from the burner center to the chamber floor. Verify that the chamber dimensions are at least as large as the minimum values given in Figure 1. If the appliance dimensions are smaller than recommended, reduce the firing rate accordingly.

Figure 1. Min. Combustion Chamber Dimensions

Figure 2 - Air Tube Mounting Dimensions

X

 

Minimum Dimensions

 

Firing Rate

 

 

(with damper)

(without damper)

 

 

 

 

 

 

A

L

A

 

L

1.75 to 3.00 gph

7.5”

18.0”

8.0”

 

19.0”

4.00 gph

8.0”

21.0”

9.5”

 

23.0”

5.00 gph

9.0”

23.0”

10.5”

 

30.0”

6.00 gph

10.0”

28.0”

11.5”

 

40.0”

7.00 gph

11.0”

34.0”

12.0”

 

46.0”

8.00 gph

14.0”

38.0”

14.0”

 

51.0”

XInstall burner with 2o pitch as shown.

Air Tube

 

A.T.C. Codes

 

(A.T.C. = Air Tube Combination)

Length

 

 

 

 

 

CF800

 

(Dimension T)

CF500

 

Tube A

 

Tube B

 

 

 

 

 

 

 

 

6.00”

CF 60 KK

CF 60 KH

 

CF 60 KJ

8.00”

CF 80 KK

CF 80 KH

 

CF 80 KJ

10.00”

CF 100 KK

CF 100 KH

 

CF 100 KJ

14.00”

CF 140 KK

CF 140 KH

 

CF 140 KJ

16.00”

CF160 KK

--

 

--

17.00”

--

CF 170 KH

 

CF 170 KJ

Page 6

6104 BCF5 R06

Image 6
Contents To the Professional, Qualified Installer or Service Agency Potential for Fire, Smoke and Asphyxiation HazardsTo the Homeowner or Equipment Owner Before you begin To the Owner Agency approvalsProtect Against Stray Light Lockout Pre-installation check- listFollow These Instructions Exactly Protect Against Dust MoistureOil Supply Pressure Control Required Correct Nozzle and Flow Rate Required‰ Verify air tube ‰ Verify firing rateMount the burner Protect the Air Tube From Overheating‰ Mount flanges on air tube ‰ Install nozzle line assembly ‰ Install nozzle‰ Check electrode settings ‰ Set dimension ZDo Not Install By-pass Plug with 1-Pipe System Install Oil Supply To SpecificationsConnect fuel lines Wire the burner R7184 Prepare the burner for start-up‰ Initial air settings Table ‰ Start-up checklist‰ Z dimension ‰ Initial head position FigureExplosion and Fire Hazard Hot Gas Puff-back Heavy Smoke Hazard‰ Starting the burner and venting air ‰ Set combustion using instruments Sequence of operation typicalMonthly maintenance by owner Maintenance and ServiceAnnual Professional Service Required Annual service by qualified service techni- cianReplacement parts Warranty Limited Warranty Information
Related manuals
Manual 36 pages 29.5 Kb Manual 16 pages 28.56 Kb