Beckett AFG, Oil Burner manual Professional Maintenance, Description

Page 15

Professional Maintenance

For best performance specify genuine Beckett replacement parts

Parts that are unique to AF burn- ers replace parts numbered 6 and

31841 AIR INLET BELL

14. Refer 2459Uto partsBLOWERlist belowWHEEL for part numbers.

SK9462

#

Part No.

Description

1

 

Burner Housing Assembly

2

Specify

Air Band - Specify # of slots

 

4198

Screw, 10-24 x 1/2”

 

4150

Nut, 10-24 Square

3

Specify

Air Shutter - Specify # of slots

 

4292

Screws, 10-24 x 5/16”

4

3493

Escutcheon (F & L1/L2 heads)

 

5941

Head Adjusting Plate (V1 head)

 

4292

Screw, 10-24 x 5/16”

5

2139

Hole Plug

6

31231U (AFG)

Air Guide (AFG)

 

31841 (AF)

Air Inlet Bell (AF)

7

5880

Low Firing Rate Baffle

8

2184404U

CleanCut Pump

 

4189U

Mounting Screws

9

21807U

Valve Cordset

 

21887U

PD Timer Delay Cordset

10

2182602U

Solenoid Valve Kit (delay)

11

2256

Pump Elbow

12

5394

Copper Oil Line - 8”

13

21805U

PSC Motor

 

4189

Mounting Screws

#

Part No.

Description

14

2999U (AFG)

Blower Wheel (AFG)

 

2459U (AF)

Blower Wheel (AF)

15

2454

Coupling

16

7455U

R7184A - Interrupted Ignition

 

7456U

R7184B - Pre-purge

 

7457U

R7184P - Pre and Post-purge

 

7458U

R7184P w/ Alarm Contacts

17

5770

Electrical Box

18

51771U

Igniter & Base Plate

19

51304

Igniter Gasket Kit

20

7006U

Cad Cell Detector

21

5432

Universal Flange w/ Gasket

 

3616

Gasket Only

22

Specify **

Air Tube Combination

23

Specify **

Heat Shield, Ceramic or Fiber

24

5780

Electrode Kit - F Head up to 9”

5782

Electrode Kit - F Head over 9”

 

 

5940

Electrode Kit - M Head up to 9”

25

3666

Splined Nut

26

5685

Pedestal Kit

27

51814U

Cover

**Contact your Beckett Representative for part num- ber and pricing.

RWB 6104 BAFG R02

Page 15

Image 15
Contents To the Professional, Qualified Installer or Service Agency Potential for Fire, Smoke and Asphyxiation HazardsTo the Homeowner or Equipment Owner Information To Be Used Only By Qualified Service Technicians Table of ContentsGeneral Information To the Owner Hazard DefinitionsGeneral Specifications Burner SpecificationsAir Tube Combination ATC codes Ventilation Air Supply Inspect/Prepare Installation SiteChimney or vent Adequate CombustionPrepare the Burner Nozzle Flow Rate by Size Check/adjust electrodesAttach air tube if not already installed Install burner nozzle if not already in- stalledBurner Dimensions Check/Adjust ‘Z’ Dimension ‘F’ headsCheck/Adjust ‘Z’ Dimension V1 Heads Check/Adjust ‘Z’ Dimension L1 & L2 HeadsMounting options Servicing nozzle line assemblyMounting dimensions Mount burner on applianceBurner packaged with appliance Wire burnerBurner installed at jobsite Special wiring required with covered burners Typical Burner Wiring Set combustion with instruments Start up burner/set combustionReplace the blower wheel Perform regular maintenanceDescription Professional MaintenanceWarranty