Beckett ADC manual Section Burner Wiring

Page 8

Section: Burner Wiring

Figure 6A. Typical Wiring For Constant Duty Ignition - With No Primary Control

SAFETY AND

LIMIT CONTROLS

50A

30A

FUSE

FUSE

ORANGE

MOTOR

OPERATING

CONTROLS

10A FUSE

BLUE WITH

SOLID

VIOLET(+)

WHITE STRIPE

WHITE

 

YELLOW

CAPPEDIGNITER VALVE

(NOT USED)

BLACK

BLACK

WHITE(-)

GND

FROM 12 - 13.5 Vdc

POWER SUPPLY

Notes:

1.Wires are to be sized to prevent a voltage drop between battery and burner with burner running at full load.

2.Motor runs continuously in normal confi guration.

3.Hard-wire burner ground to battery. DO NOT USE CHASSIS GROUND SYSTEM.

SK10087

Figure 6B. Typical Wiring For Interrupted Ignition - With No Primary Control

SAFETY AND

LIMIT CONTROLS

50A

30A

FUSE

FUSE

OPERATING CONTROLS

10A FUSE

ORANGE

VIOLET(+)

SOLID

BLUE W/

WHITE

WHITE STRIPE

 

 

MOTOR

VALVE

IGNITER

YELLOW

CAD

CELL

 

 

 

YELLOW

 

 

 

 

BLACK

WHITE(-)

BLACK

GND

FROM 12 - 13.5 Vdc

POWER SUPPLY

Notes:

1.Wires aret to be sized to prevent a voltage drop between battery and burner with burner running at full load.

2.Hard-wire burner ground to battery. DO NOT USE CHASSIS GROUND SYSTEM.

SK10088

8

Image 8
Contents 12Vdc Oil Burner Manual Potential for Fire, Smoke and Asphyxiation HazardsContents Prepare Before Installing Specifications Owner’s ResponsibilityGeneral Information Replace the Burner Nozzle Nozzle Assembly MaintenanceLow Firing Rate Baffle Check/Adjust Electrodes Igniter MaintenanceServicing Nozzle Line Assembly Check/Adjust Z DimensionBurner Wiring Fuel SupplySection Burner Wiring Drive Component Maintenance Motor, Blower Wheel, and Coupling ReplacementPump Maintenance Valve Coil and Stem ReplacementStart Up Burner & Set Combustion Basic Burner OperationSet Combustion with Instruments Combustion Set-upExplosion and Fire Hazard Maintain & Service Burner Owner’s Information Professional Service RequiredOwner Service and Maintenance Regular Service/MaintenanceTroubleshooting 125 140 150 175 200Rated Psi PsigTroubleshooting Chart Replacement Parts 2320 1618Limited Warranty Information

ADC specifications

Beckett Advanced Digital Control (ADC) represents a significant advancement in the world of heating technology, offering homeowners enhanced efficiency, control, and convenience in managing their heating systems. This innovative technology is designed to integrate seamlessly with various heating solutions, including oil and gas furnaces, boilers, and water heaters.

One of the main features of Beckett ADC is its advanced control algorithms, which enable precise modulation of fuel delivery and combustion processes. This modulation not only optimizes energy consumption but also minimizes emissions, ensuring compliance with environmental standards. The ADC system intelligently adjusts the fuel flow based on the heating demands of the home, thus achieving a high degree of efficiency.

The user interface of the Beckett ADC is another standout characteristic. It features a digital display that provides real-time feedback on system performance, making it easy for homeowners to monitor their heating systems. The interface is designed to be user-friendly, allowing for quick adjustments and settings changes without technical expertise.

In terms of technology, Beckett ADC utilizes sophisticated sensors that monitor various parameters, including temperature, pressure, and airflow. This data is constantly analyzed to ensure optimal operation. The system also incorporates advanced ignition technology, which allows for a quick and reliable start, thus enhancing the overall user experience.

Another key characteristic of Beckett ADC is its compatibility with smart home systems. Many models are designed to connect with Wi-Fi and can be integrated into home automation platforms. This allows homeowners to control their heating systems remotely, enabling features such as scheduling, temperature adjustments, and real-time monitoring from a smartphone or tablet.

Additionally, Beckett ADC is known for its durability and low maintenance requirements. The design incorporates high-quality materials that resist wear and tear, allowing for a longer lifespan and reliable operation over time. This durability ensures that homeowners can enjoy an efficient heating system without the frequent need for repairs or replacements.

In summary, Beckett ADC stands out in the heating industry for its advanced digital control capabilities, user-friendly interface, sophisticated sensor technology, smart home compatibility, and durable design. These features come together to create an efficient, convenient, and environmentally friendly heating solution for modern homes, underscoring Beckett's commitment to innovation and quality in heating technology.