Lochinvar 210, 50 manual Contents

Page 2

Contents

HAZARD DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 2 PLEASE READ BEFORE PROCEEDING . . . . . . . . . . . . 3

1. PREVENT COMBUSTION AIR CONTAMINATION . . . 4

2. MAINTENANCE SCHEDULE . . . . . . . . . . . . . . . . . . . . 5 Maintenance Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Boiler Must Be Serviced and Maintained . . . . . . . . . . 6 Check Boiler Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Check Pressure Temperature Gauge . . . . . . . . . . . . . 6 Check Vent Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Check Air Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Check Relief Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Check Condensate Drain System . . . . . . . . . . . . . . . . 6-7 Check Air Vents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Test Low Water Cutoff (if installed) . . . . . . . . . . . . . . . 8 Reset Button (low water cutoff) . . . . . . . . . . . . . . . . . . 8 Check Boiler Piping (gas and water) . . . . . . . . . . . . . . 8 Operate Relief Valve . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Shut Boiler Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

3. OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . 9

4. SMART SYSTEM CONTROL MODULE

SMART SYSTEM Control Module . . . . . . . . . . . . . . . . . . 10

Access Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Saving Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Parameter Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

A: General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

B: Temperature Settings . . . . . . . . . . . . . . . . . . . . . . . 13

C: Data Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

E: DHW Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

F: Outdoor Air Reset . . . . . . . . . . . . . . . . . . . . . . . . . 14

Status Display Screens . . . . . . . . . . . . . . . . . . . . . . . . . . 15-18

NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Revision Notes . . . . . . . . . . . . . . . . . . . . . . . . . Back Cover

Hazard definitions

The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product.

￿DANGER

￿WARNING

￿CAUTION

CAUTION

NOTICE

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.

NOTICE indicates special instructions on installation, operation, or maintenance that are important but not related to personal injury or property damage.

2

Image 2
Contents User’s Information Manual Models 50 Save this manual for future referenceContents Boiler service and maintenance Please read before proceedingAreas likely to have contaminants Prevent combustion air contaminationProducts to avoid See pages 6 8 for detailed instructions Maintenance schedule Service technicianOwner maintenance Maintenance schedule 1Condensate Trap Condensate disposalCheck air vents Test low water cutoff if installedReset button low water cutoff Operate relief valveOperating instructions Smart System control module Knight wall mount control moduleUser Access modesInstaller To save parameters and exit programmingParameter table Data logging Temperature settingsGeneral DHW settings Outdoor air resetSet Point Met ServiceStandby PrepurgeSYS ***.*F Control will display the actual fan motor RPMDelay 10V in **.VdcOperation of the cascade User’s Information Manual