Burnham V9 Series Burners: Complete Guide to Specifications and Models

Page 7

V9 Series Burner Schedule

V9 Series Burners

OIL BURneRS

OIL BURneRS

 

BeCKeTT

 

CARLIn

 

pOWeR FLAMe

WeBSTeR

 

 

 

 

 

 

 

 

 

 

 

 

 

BOILeR

BURneR

 

 

BURneR

 

 

BURneR

 

BURneR

 

 

MODeL

MODeL

 

H.p.

MODeL

 

H.p.

MODeL

H.p.

MODeL

 

H.p.

 

 

 

 

 

 

 

 

 

 

 

 

V903A

CF500

 

1/3

301CRD

 

1/4

Ñ

Ñ

Ñ

 

Ñ

V904A

CF800

 

1/3

301CRD

 

1/4

C1-OS

1/3

Ñ

 

Ñ

V905A

CF800

 

1/3

301CRD

 

1/4

C1-OS

1/3

JB1O-02

 

1/4

V906A

CF1400

 

1/2

702CRD

 

1/2

C1-OS

1/2

JB1O-03

 

1/3

V907A

CF1400

 

1/2

702CRD

 

1/2

C1-OS

1/2

JB1O-03

 

1/3

V908A

CF1400

 

1/2

702CRD

 

1/2

C2-OAS

3/4

JB1O-03

 

1/3

V909A

CF2300A

 

3/4

801CRD

 

3/4

C2-OAS

3/4

JB1O-05

 

1/2

V910A

CF2300A

 

3/4

801CRD

 

3/4

C2-OAS

3/4

JB1O-05

 

1/2

V911A

CF2500A

 

2

801CRD

 

3/4

C2-OB

1-1/2

JB1O-07

 

3/4

V912A

CF2500A

 

2

801CRD-B

 

1-1/2

C2-OB

1-1/2

JB1O-07

 

3/4

 

 

 

 

 

 

 

 

 

 

 

 

Standard Burner Motor Voltage:

Beckett – CF500, CF800, CF1400, and CF2300A are 120/60/1. CF2500A is 240/60/1. Carlin – 301CRD and 702CRD are 120/60/1. 801CRD is 240/60/1.

power Flame C1-OS is 120/60/1. C2-OAS and C2-OB are 240/60/1. Webster JB1O-02, JB1O-03, and JB1O-05 are 120/60/1. JB1O-07 is 240/60/1.

Optional Motor Voltage:

Most models have 208-240 or 480 volts/3phase available at additional cost as an option. Consult your Burnham Commercial sales representative.

GAS BURneRS*

 

 

 

 

pOWeR FLAMe*

pOWeR FLAMe

 

 

 

 

BeCKeTT

C SeRIeS

 

JR SeRIeS

WeBSTeR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MIn. GAS

 

 

 

 

 

MIn. GAS

 

MIn. GAS

BOILeR

BURneR

 

pReSSURe

BURneR

 

BURneR

 

 

pReSSURe

BURneR

pReSSURe

MODeL

MODeL

H.p.

InCHeS

MODeL

H.p.

MODeL

 

H.p.

InCHeS

MODeL

InCHeS

 

 

 

 

 

 

 

 

 

 

 

 

V903A

CG10-1S

1/3

3.3

Ñ

Ñ

JR15A-10

 

1/4

4.0

Ñ

Ñ

V904A

CG10-4S

1/3

3.7

C1-G-10

1/3

JR30A-10

 

1/3

4.2

JB1G-02

5.0

V905A

CG10-5S

1/3

4.7

C1-G-10

1/3

JR30A-12

 

1/3

5.9

JB1G-02

8.0

V906A

CG10-6S

1/3

5.5

C1-G-12

1/2

JR30A-12

 

1/3

4.3

JB1G-02

5.0

V907A

CG15-3S

1/2

5.4

C1-G-12

1/2

JR50A-15

 

1/3

5.4

JB1G-02

6.0

V908A

CG15-4S

1/2

6.2

C2-G-15

1/2

JR50A-15

 

1/3

4.4

JB1G-03

8.0

V909A

CG25-2S

3/4

4.7

C2-G-20A

3/4

JR50A-15

 

1/3

5.0

JB1G-05

6.0

V910A

CG25-3S

3/4

5.0

C2-G-20A

3/4

Ñ

 

Ñ

Ñ

JB1G-05

6.0

V911A

CG25-4S

3/4

4.9

C2-G-20B

1

Ñ

 

Ñ

Ñ

JB1G-07

7.0

V912A

CG50-2S

2

3.9

C2-G-20B

1

Ñ

 

Ñ

Ñ

JB1G-07

9.0

 

 

 

 

 

 

 

 

 

 

 

 

Standard Motor Voltage:

Beckett – V903 through V911 120/60/1, V912 240/60/1

power Flame C Series C1-G-10, C1-G-12, C2-G-15 are 120/60/1. C2-G-20A and C2-G-20B are 240/60/1. power Flame JR Series – All burners are 120/60/1.

Webster –JB1G-02, JB1G-03 and JB1G-05 are 120/60/1. JB1G-07 is 240/60/1.

GAS/OIL BURneRS

Optional Burner Motor Voltage:

Most models have 208-240 or 480 volts/3phase available at additional cost as an option. Consult your Burnham Commercial sales representative.

*For gas connection size on Gordon-Piatt,Webster and Power Flame C burners and minimum gas pressure for C burner see gas/oil burner chart.

 

 

pOWeR FLAMe - C SeRIeS

 

 

WeBSTeR**

 

 

 

 

 

 

 

 

 

 

 

InLeT GAS

MIn. GAS

 

 

InLeT GAS

BOILeR

BURneR

 

COnneCTIOn

pReSSURe

BURneR

 

COnneCTIOn

MODeL

MODeL

H.p.

InCHeS

InCHeS

MODeL

H.p.

InCHeS

 

 

 

 

 

 

 

 

V904A

C1-GO-10

1/3

1

4.4

Ñ

Ñ

Ñ

V905A

C1-GO-10

1/3

1

4.4

JB1C-02

1/4

1-1/4

V906A

C1-GO-12

1/2

1

4.8

JB1C-03

1/3

1-1/4

V907A

C1-GO-12

1/2

1

5.2

JB1C-03

1/3

1-1/2

V908A

C2-GO-15

3/4

1

6.4

JB1C-05

1/2

1-1/2

V909A

C2-GO-20A

1

1-1/4

4.9

JB1C-05

1/2

1-1/2

V910A

C2-GO-20A

1

1-1/4

5.2

JB1C-05

1/2

1-1/2

V911A

C2-GO-20B

1-1/2

1-1/4

5.4

JB1C-07

3/4

2

V912A

C2-GO-20B

1-1/2

1-1/2

5.0

JB1C-10

1

2

 

 

 

 

 

 

 

 

Standard Burner Motor:

power Flame C1-GO-10 and C1-GO-12 are 120/60/1. C2-GO-15, C2-GO-20A and C2-GO-20B are 240/60/1. Webster JB1C-02, JB1C-03, and JB1C-05 are 120/60/1. JB1C-07 and JB1C-10 are 240/60/1.

Optional Burner Motor Voltage: Most models have 208-240 or 480 volts/ 3phase available at additional cost as an option. Consult your Burnham Commercial sales representative.

**For minimum gas pressure requirements, see gas burner chart.

7

Image 7
Contents V9Series American-Made Cast Iron ConstructionÐ BC25-HSi Installation & Service FlexibilityCommitment to Quality V9 Series Hot Water or Steam BoilerSBCª Boiler Control System SBCV9 Series Dimensions PIpInG SIZe In InCHeS V9 Series Piping RecommendationsQty. SIZe GAS/OIL BURneRS V9 Series BurnersOIL BURneRS GAS BURneRSSTAnDARD eQUIpMenT V9 Series Ratings Equipment ListingOpTIOnAL eQUIpMenT