V9 Series Burner Schedule
V9 Series Burners
OIL BURneRS
OIL BURneRS
| BeCKeTT |
| CARLIn |
| pOWeR FLAMe | WeBSTeR |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
BOILeR | BURneR |
|
| BURneR |
|
| BURneR |
| BURneR |
|
|
MODeL | MODeL |
| H.p. | MODeL |
| H.p. | MODeL | H.p. | MODeL |
| H.p. |
|
|
|
|
|
|
|
|
|
|
|
|
V903A | CF500 |
| 1/3 | 301CRD |
| 1/4 | Ñ | Ñ | Ñ |
| Ñ |
V904A | CF800 |
| 1/3 | 301CRD |
| 1/4 | 1/3 | Ñ |
| Ñ | |
V905A | CF800 |
| 1/3 | 301CRD |
| 1/4 | 1/3 |
| 1/4 | ||
V906A | CF1400 |
| 1/2 | 702CRD |
| 1/2 | 1/2 |
| 1/3 | ||
V907A | CF1400 |
| 1/2 | 702CRD |
| 1/2 | 1/2 |
| 1/3 | ||
V908A | CF1400 |
| 1/2 | 702CRD |
| 1/2 | 3/4 |
| 1/3 | ||
V909A | CF2300A |
| 3/4 | 801CRD |
| 3/4 | 3/4 |
| 1/2 | ||
V910A | CF2300A |
| 3/4 | 801CRD |
| 3/4 | 3/4 |
| 1/2 | ||
V911A | CF2500A |
| 2 | 801CRD |
| 3/4 |
| 3/4 | |||
V912A | CF2500A |
| 2 |
|
| 3/4 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
Standard Burner Motor Voltage:
Beckett – CF500, CF800, CF1400, and CF2300A are 120/60/1. CF2500A is 240/60/1. Carlin – 301CRD and 702CRD are 120/60/1. 801CRD is 240/60/1.
power Flame –
Optional Motor Voltage:
Most models have
GAS BURneRS*
|
|
|
| pOWeR FLAMe* | pOWeR FLAMe |
|
| ||||
|
| BeCKeTT | C SeRIeS |
| JR SeRIeS | WeBSTeR | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MIn. GAS |
|
|
|
|
| MIn. GAS |
| MIn. GAS |
BOILeR | BURneR |
| pReSSURe | BURneR |
| BURneR |
|
| pReSSURe | BURneR | pReSSURe |
MODeL | MODeL | H.p. | InCHeS | MODeL | H.p. | MODeL |
| H.p. | InCHeS | MODeL | InCHeS |
|
|
|
|
|
|
|
|
|
|
|
|
V903A | 1/3 | 3.3 | Ñ | Ñ |
| 1/4 | 4.0 | Ñ | Ñ | ||
V904A | 1/3 | 3.7 | 1/3 |
| 1/3 | 4.2 | 5.0 | ||||
V905A | 1/3 | 4.7 | 1/3 |
| 1/3 | 5.9 | 8.0 | ||||
V906A | 1/3 | 5.5 | 1/2 |
| 1/3 | 4.3 | 5.0 | ||||
V907A | 1/2 | 5.4 | 1/2 |
| 1/3 | 5.4 | 6.0 | ||||
V908A | 1/2 | 6.2 | 1/2 |
| 1/3 | 4.4 | 8.0 | ||||
V909A | 3/4 | 4.7 | 3/4 |
| 1/3 | 5.0 | 6.0 | ||||
V910A | 3/4 | 5.0 | 3/4 | Ñ |
| Ñ | Ñ | 6.0 | |||
V911A | 3/4 | 4.9 | 1 | Ñ |
| Ñ | Ñ | 7.0 | |||
V912A | 2 | 3.9 | 1 | Ñ |
| Ñ | Ñ | 9.0 | |||
|
|
|
|
|
|
|
|
|
|
|
|
Standard Motor Voltage:
Beckett – V903 through V911 120/60/1, V912 240/60/1
power Flame C Series –
Webster
GAS/OIL BURneRS
Optional Burner Motor Voltage:
Most models have
*For gas connection size on
|
| pOWeR FLAMe - C SeRIeS |
|
| WeBSTeR** | ||
|
|
|
|
|
|
|
|
|
|
| InLeT GAS | MIn. GAS |
|
| InLeT GAS |
BOILeR | BURneR |
| COnneCTIOn | pReSSURe | BURneR |
| COnneCTIOn |
MODeL | MODeL | H.p. | InCHeS | InCHeS | MODeL | H.p. | InCHeS |
|
|
|
|
|
|
|
|
V904A | 1/3 | 1 | 4.4 | Ñ | Ñ | Ñ | |
V905A | 1/3 | 1 | 4.4 | 1/4 | |||
V906A | 1/2 | 1 | 4.8 | 1/3 | |||
V907A | 1/2 | 1 | 5.2 | 1/3 | |||
V908A | 3/4 | 1 | 6.4 | 1/2 | |||
V909A | 1 | 4.9 | 1/2 | ||||
V910A | 1 | 5.2 | 1/2 | ||||
V911A | 5.4 | 3/4 | 2 | ||||
V912A | 5.0 | 1 | 2 | ||||
|
|
|
|
|
|
|
|
Standard Burner Motor:
power Flame –
Optional Burner Motor Voltage: Most models have
**For minimum gas pressure requirements, see gas burner chart.
7