Burnham 20_PV_I manual Avoid Breathing Fiber Particulates and Dust

Page 20

Important Product Safety Information

Refractory Ceramic Fiber Product

Warning:

This product contains refractory ceramic fibers (RCF). RCF has been classified as a possible human carcinogen. After this product is fired, RCF may, when exposed to extremely high temperature (>1800F), change into a known human carcinogen. When disturbed as a result of servicing or repair, RCF becomes airborne and, if inhaled, may be hazardous to your health.

AVOID Breathing Fiber Particulates and Dust

Precautionary Measures:

Do not remove or replace previously fired RCF (combustion chamber insulation, target walls, canopy gasket, flue cover gasket, etc.) or attempt any service or repair work involving RCF without wearing the following protective gear:

1.A National Institute for Occupational Safety and Health (NIOSH) approved respirator

2.Long sleeved, loose fitting clothing

3.Gloves

4.Eye Protection

Take steps to assure adequate ventilation.

Wash all exposed body areas gently with soap and water after contact.

Wash work clothes separately from other laundry and rinse washing machine after use to avoid contaminating other clothes.

Discard used RCF components by sealing in an air tight plastic bag.

First Aid Procedures:

If contact with eyes: Flush with water for at least 15 minutes. Seek immediate medical attention if irritation persists.

If contact with skin: Wash affected area gently with soap and water. Seek immediate medical attention if irritation persists.

If breathing difficulty develops: Leave the area and move to a location with clean fresh air. Seek immediate medical attention if breathing difficulties persist.

Ingestion: Do not induce vomiting. Drink plenty of water. Seek immediate medical attention.

20

Image 20
Contents Series 2PV 8141775R12-3/01 Price $3.00Table of Contents Elevation Views Pre-Installation II. Unpack Boiler Alternate method for boiler located within confinedIII. Water Piping and Trim Page Connect boiler gas valve to gas supply system IV. Gas PipingRated Input Venting Fitting Equivalent LengthsSpecific Gravity Correction Factors General GuidelinesInstall Vent Connector Burnham Vent System ComponentsInstall Vent Pipe, General Horizontal Through Wall Vent InstallationVI. Electrical Recommendations for Thimble and Wall PenetrationMain Burner Installation VII. System Start-upGas Valve Pressure Tap Prepare to check operationGas Flow Rate in Cubic Feet per Hour Adjust gas input rate to boiler Natural GasCheck limit Operating Instructions Trouble Shooting Guide Page Page Avoid Breathing Fiber Particulates and Dust VIII. Service Clean Main Burners and FireboxSpark Gap Setting Pilot Burner LocationProcedure for Measuring Fan Suction Pressure Minimum Suction PressureIX. Repair Parts Burnham Corporation Regional OfficesSection Assembly Canopy/Blower AssemblyBase Assembly Group Manifold and Main Burners Pilot Burner and Gas Valve Jacket Page Vent Accessory Carton

20_PV_I specifications

The Burnham 20_PV_I is a high-efficiency, versatile heating solution designed for residential and commercial applications. Renowned for its performance and reliability, the Burnham 20_PV_I is a notable choice for those seeking an effective way to heat their spaces.

One of the standout features of the Burnham 20_PV_I is its innovative design, which incorporates a range of advanced technologies to maximize thermal efficiency. The boiler operates using a proven cast iron heat exchanger that ensures optimal heat transfer. This not only allows for rapid heating but also contributes to the longevity of the unit. With a heating capacity of 20,000 BTUs, it is well-suited for medium-sized spaces, making it ideal for heating homes or small businesses.

Efficiency is a key attribute of the Burnham 20_PV_I, which boasts an impressive AFUE (Annual Fuel Utilization Efficiency) rating. This high efficiency translates into lower fuel consumption, resulting in reduced energy bills for users. The boiler is designed to operate with various fuel types, accommodating natural gas and propane options, which provides flexibility depending on regional availability and price factors.

Another notable characteristic of the Burnham 20_PV_I is its user-friendly control system. The boiler features an integrated digital control panel that allows users to easily set desired temperatures and monitor system performance. This level of control enhances comfort while also enabling owners to proactively maintain efficiency.

In terms of installation, the Burnham 20_PV_I is designed with convenience in mind. Its compact dimensions allow it to be installed in various locations, including basements and utility rooms, without taking up excessive space. Plus, the unit's lightweight construction facilitates easier handling during the installation process.

Safety is paramount in the design of the Burnham 20_PV_I, which includes multiple safety features such as a high limit temperature control, pressure relief valve, and robust emergency shutoff systems. These features ensure reliable operation and peace of mind for users.

Overall, the Burnham 20_PV_I stands out as a robust, efficient, and user-friendly heating solution. With its advanced technologies, impressive efficiency ratings, and committed focus on safety and reliability, it represents an excellent investment for anyone looking to enhance their heating systems, providing warmth and comfort for years to come.