The following terms are used throughout this manual to bring attention to the presence of hazards of various risk levels.

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in death, serious injury or substantial property damage.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in moderate or minor injury or property damage.

Basic Operation

DANGER

There are no user serviceable parts on this boiler. Attempts to service this boiler by someone other than a qualified gas service technician could void the warranty, cause property damage, personal injury or loss of life.

CAUTION

Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance.

En cas de surchauffe ou si I'admission de gaz ne peut étre coupée, ne pas couper ni débrancher l'alimentation électrique de la pompe. Fermer plutôt le robinet d'admission de gaz à l'extérieur de I'appareil.

Do not use this boiler if any part has been under water. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water.

CAUTION

Like all central heating appliances, this boiler is equipped with safety devices, which could cause it to shutdown, requiring service to restore normal operation. Where such a shutdown could result in damage from low temperatures (such as frozen pipes), do not leave the heating system unattended during cold weather unless alarms or other safeguards are in place to prevent damage.

A.General

1.This manual covers the proper care and use of the

Alpine™ (ALP) Condensing High Efficiency Gas

Fired Boiler

2.Instructions to safely light and shut down this boiler are shown on page 4, as well as on a label affixed to the boiler. Control locations shown in Figure 1.

3.The Alpine™ (ALP) boilers use an electronic means built into the ignition system to extinguish the burner in the event that flames exit the combustion chamber. If the boiler fails to fire, call a qualified heating service agency to diagnose and correct the problem.

4.Alpine™ (ALP) boilers – These boilers are equipped with a safety feature which will shut down the burner in the event that there is a blockage in the vent system. In the event that the boiler fails to function, and the boiler is vented through an outside wall accessible from the ground, inspect the vent terminal on the outside wall for a blockage such

as a bee’s nest or ice. If a blockage is found, the burner should ignite approximately 30 seconds after the blockage is removed. If no blockage is found, or if the terminal is inaccessible from the ground, the problem must be diagnosed and corrected by a qualified gas service technician.

Image 2
Contents Alpine Basic Operation GeneralMaintenance Control Locations shown with optional concentric vent collar Alpine Series Lighting and Operating Instructions Inspect Concentric Inlet Air/Vent System Monthly User MaintenanceGeneral Housekeeping Continuous Inspect burner Flames MonthlyPage Avoid Breathing Fiber Particulates and Dust