Guaranteed efficiency and easy maintenance assure low cost operation
All Bryan RV Series boilers offer these operating and performance features
Guaranteed efficiency
The breakthrough in water tube boiler design that pro- duced the RV Series provides operating efficiency so reliable, we guarantee it to be 84% for hot water boilers and 82% - 15 psi / 80% - 150 psi or better for steam boilers.
The Bryan Flexible Tube
Bryan’s exclusive “Flexible Tube” design eliminates the possibility of damage from
ever be required.
Water cooled furnace
The configuration of the water tubes provides a water cooled combustion chamber. A high percentage
of the heating surface is exposed to direct radiant heat, increasing water velocities and heat transfer.
Large steam drum
The steam drum has generous water volume and steam release area. This design, along with effective drum internal functions, results in a stable water level and produces extremely dry steam at all load conditions.
Accessibility of furnace and tube area
Inner panel provides easy and complete access to furnace and boiler tube area, as well as to burner head. All panels are heavily insulated and sealed to boiler frame. All access is from only one side.
Compact design, minimum floor space
With our compact water tube design, the overall size of the unit is less than most other types of boilers, yet maintains a full five square feet of heating surface area per HP.
Needing only 32" for tube removal, and on only one side of the boiler, the RV Series boiler occupies very little space in the boiler room. This can result in considerable savings in building costs. Pressurized firing permits minimum sized breaching and vent.
Multi-pass flue gas travel
High velocity
Thermal blend water return
Bryan’s unique “thermal blend” return blends cold or cooler return water with warmer boiler water abridging it to design operating temperatures. An injector tube directs the “mixed” water flow through the downcomer to the lower header and heating surfaces at a temperature above possible condensing conditions. This reduces the possi- bility of “cold spots” and
damage from corrosive condensation.
Positive internal circulation
Each pass of the Bryan water tube slopes up- ward. This configuration, along with the large vol- ume
damage caused by unequal temperature distribution is especially important for heating systems, particularly where intermittent or continuous low temperature water returns may be encountered.
Bryan RV Series Boilers Standard and Optional Equipment
Hot water boiler
STANDARD EQUIPMENT FURNISHED
OPTIONAL EQUIPMENT,
Optional construction to ASME Power BoilerCoderequirementsfortempera-
Water Boiler
Combinationthermometerandaltitude gauge, ASME Code rated boiler relief valve, water temperature control (240°F max std.), high limit control, probe LWCO.
Steam Boiler
Steam pressure gauge, steam pres- sure control, combination low water cutoff and pump control, auxiliary low water cutoff, high limit pressure control,
Straight gas fired unit
Electronic combustion safety control, automatic operating gas valve, safety gas valve, pilot solenoid valve, pilot ignition assembly, main manual gas
switch, control panel, all controls installed and wired.
Straight oil fired unit
Electronic combustion safety control, dual oil valves oil ignition transformer,
Combination gas-oil unit
Electronic combustion safety control, automatic operating gas valve, safety gas valve, pilot solenoid valve, pilot ignition assembly, main manual gas
EXTRA COST
1.Manual reset high limit control
2.Manual reset low water cutoff
3.Auxiliary low water cutoff
4.Combination low water cutoff and feeder
5.Alarm bells or horns
6.UL, CUL,
7.Indicating lights, as desired
8.
9.Draft control system
10.Low NOx package
OPTIONAL CONSTRUCTION
Steam boiler
Optional construction to ASME Power Boiler Code requirements for pressure exceeding 150 psi to maximum of 300 psi design pressure.
turesexceeding240°Fand/orpressure exceeding 160 psi to maximum of 285° F operating and 300° F design temperature and 250 psi.
When ordering, please specify:
1.Boiler size
2.Supply and return tempera- tures required
3.Boiler relief valve setting
4.Type of fuel: natural, LP, or other gas and/or No. 2 oil
5.If gas, type, BTU content, specific gravity and pressure available
6.Electric power voltage, phase and frequency
7.Optional extra equipment or construction
8.Special approvals required (UL, CUL,
9.Altitude