White Rodgers 1F56N-911 installation instructions Installation Instructions, Description

Page 1

1F56N-911

Low Voltage Heating/Cooling Thermostat

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

This low voltage thermostat is designed to provide conve- nient control of the heating/cooling system. To provide greater room comfort, the sensitive spiral bimetal is com- bined with an adjustable heating anticipator and a fixed cooling anticipator to provide maximum comfort.

DESCRIPTION

FAN

 

SYSTEM

 

AUTO

ON

COOL OFF

HEAT

 

°C

°C

 

90

32

32

90

80

 

 

80

70

21

21

70

60

 

 

 

60

 

 

 

50

10

10

50

 

 

If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor, electrician, or someone familiar with basic electricity and wiring.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

CONTENTS

 

Description

1

Precautions

1

Specifications

2

Installation

2

Select Thermostat Location

 

Route Wires to Location

 

Attach Subbase to Wall

 

Special System Configurations

 

Electric Heat Furnaces (Single Trans-

 

former Systems Only)

 

Two-Transformer Systems

 

Heat Pump Applications

 

Special Application Terminals

 

Attach Thermostat to Subbase

 

Operation & Maintenance

5

Adjusting Heat Anticipator

 

Calibrating Thermostat

 

PRECAUTIONS

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Do not short out terminals on gas valve or pri- mary control to test. Short or incorrect wiring will burn out heat anticipator and could cause per- sonal injury and/or property damage.

!WARNING

Do not use on circuits exceeding 30 volts. Higher voltage will damage control and could cause shock or fire hazard.

Thermostat installation and all components of the system shall conform to Class II circuits per the NEC code.

White-Rodgers is a division

PART NO. 37-6923A

of Emerson Electric Co.

 

www.white-rodgers.com

0807

Image 1
Contents Precautions Installation InstructionsContents DescriptionInstallation SpecificationsRoute Wires to Location Select Thermostat LocationAttach Subbase to Wall Special System ConfigurationsAttach Thermostat to Subbase System Factory-installed Red Jumper Wire Operation MaintenanceCalibrating Thermostat Adjusting Heat AnticipatorPage Homeowner Help Line

1F56N-911 specifications

The White Rodgers 1F56N-911 is a highly regarded thermostat known for its efficiency and user-friendly features. This device is specifically designed to maintain optimal indoor climate control while offering energy-saving capabilities. Its sleek design and practical functionalities make it a preferred choice for homeowners looking to enhance their HVAC systems.

One of the standout features of the 1F56N-911 is its digital display, which provides clear, easy-to-read temperature settings. The large LCD screen enables users to quickly view and adjust the temperature without any hassle. Furthermore, it comes equipped with a set of intuitive controls, allowing for straightforward navigation through its functionalities.

The thermostat supports a range of heating and cooling systems, making it highly adaptable to different home environments. It is compatible with traditional gas and electric systems as well as heat pumps, which makes it a versatile option for various HVAC setups. The 1F56N-911 is designed to work seamlessly with multi-stage heating and cooling systems, ensuring precise temperature regulation and comfort.

Energy efficiency is a pivotal feature of the White Rodgers 1F56N-911. It includes programmable capabilities, enabling users to set schedules for different times of the day. This allows for reduced energy consumption when the home is unoccupied or during the night. Users can program up to four distinct periods within a day, ensuring that the system operates effectively while minimizing energy bills.

Additionally, the 1F56N-911 incorporates advanced technologies such as adaptive recovery and smart temperature control. Adaptive recovery allows the thermostat to learn how long it takes to heat or cool the space, initiating the system earlier to achieve the desired temperature right when needed. This feature optimizes energy use while ensuring comfort.

Another significant characteristic of this thermostat is its flexibility in installation. The device is designed for easy installation, often compatible with standard wall plates and wiring configurations, which minimizes installation time for DIY enthusiasts and professionals alike.

In conclusion, the White Rodgers 1F56N-911 thermostat combines modern technology with user-centric design. Its programmable features, adaptability across different systems, energy-saving characteristics, and ease of installation make it an excellent choice for anyone looking to improve their home's comfort and efficiency. With its reliable performance, the 1F56N-911 serves as an essential tool for effective climate control.