White Rodgers 1F56N-911 Specifications, Installation, Select Thermostat Location

Page 2

SPECIFICATIONS

ELECTRICAL DATA

APPLICATIONS

Switch Rating: 24 VAC (30 VAC max.)

The 1F56N is designed for use with

Heating - 0.15 to 1.2 Amps

• Standard heating and cooling systems

Cooling - 0 to 1.5 Amps

Electric heating and cooling systems

Switch Action: SPST - Snap Action

• Single stage heat pump systems

Anticipator Rating:

Two-transformer systems

Heating - Adjustable from 0.15 to 1.2 Amps

Electronic air cleaners

Cooling - Fixed 24 VAC

• Humidifiers

THERMAL DATA

• Zone dampers

 

 

Temperature Range: 50°F to 90°F (10°C to 32°C)

This thermostat CANNOT BE USED with:

Differential: 1°F

Millivolt systems

 

Multi-stage applications

INSTALLATION

ATTENTION: This product does not contain mercury. However, t his product may replace a unit which contains mercury.

Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing non-absorbent gloves, take up the spilled mercury and place into a container which can be sealed. If a cell becomes dam- aged, the unit should be discarded.

Mercury must not be discarded in household trash. When the unit this product is replacing is to be discarded, place in a suitable container and return to White-Rodgers at 2895 Harrison Street, Batesville, AR 72501-2117 for proper disposal.

SELECT THERMOSTAT LOCATION

Proper location insures that the thermostat will provide a comfortable home temperature. Observe the following general rules when selecting a location:

1.Locate thermostat about 5 ft. above the floor.

2.Install thermostat on a partitioning wall, not on an outside wall.

3.Never expose thermostat to direct light from lamps, sun, fireplaces or any temperature radiating equip- ment.

4.Avoid locations close to windows, adjoining outside walls, or doors that lead outside.

5.Avoid locations close to air registers or in the direct path of air from them.

6.Make sure there are no pipes or duct work in that part of the wall chosen for the thermostat location.

7.Never locate thermostat in a room that is warmer or cooler than the rest of the home, such as the kitchen.

8.Avoid locations with poor air circulation, such as behind doors or in alcoves.

9.The living or dining room is normally a good location, provided there is no cooking range or refrigerator on opposite side of wall.

ROUTE WIRES TO LOCATION

NOTE

All wiring must conform with local and national electrical codes and ordinances.

1.If an old thermostat being replaced is in a satisfactory location, and the wiring appears to be in good condi- tion, use existing wiring. If in doubt, re-wire.

2.If a new location is chosen or if this is a new installa- tion, thermostat wiring must first be run to the location selected.

3.Probe for obstructions in partition before drilling 1¦2” hole in wall at selected location. Take up quarter round and drill a small guide hole for sighting (see fig. 1). From basement, drill 3¦4” hole in partition floor next to guide hole. In houses without basements, drill 1¦2” hole through ceiling and into partition from above (see fig. 1).

4.Through this hole drop a light chain, or 6” chain attached to a strong cord. Snag cord in basement with hooked wire. In houses without basements, drop cord through hole in ceiling and down partitioning; snag cord at the thermostat location.

5.Attach thermostat wires to cord and pull thermostat wires through hole in wall so that 6” of wire protrudes.

12” hole for

 

thermostat wire

 

Stout cord with 6”

 

chain attached

 

Baseboard

Approximately

5 feet from floor

strip moulding

 

14” guide hole

 

for sighting

 

Quarter round

 

removed

 

34” hole in floor of partition

Hooked wire for snagging chain

Figure 1. Routing thermostat wires

2

Image 2
Contents Contents Installation InstructionsPrecautions DescriptionRoute Wires to Location SpecificationsInstallation Select Thermostat LocationAttach Thermostat to Subbase Special System ConfigurationsAttach Subbase to Wall System Operation Maintenance Factory-installed Red Jumper WireAdjusting Heat Anticipator Calibrating ThermostatPage Homeowner Help Line

1F56N-911 specifications

The White Rodgers 1F56N-911 is a highly regarded thermostat known for its efficiency and user-friendly features. This device is specifically designed to maintain optimal indoor climate control while offering energy-saving capabilities. Its sleek design and practical functionalities make it a preferred choice for homeowners looking to enhance their HVAC systems.

One of the standout features of the 1F56N-911 is its digital display, which provides clear, easy-to-read temperature settings. The large LCD screen enables users to quickly view and adjust the temperature without any hassle. Furthermore, it comes equipped with a set of intuitive controls, allowing for straightforward navigation through its functionalities.

The thermostat supports a range of heating and cooling systems, making it highly adaptable to different home environments. It is compatible with traditional gas and electric systems as well as heat pumps, which makes it a versatile option for various HVAC setups. The 1F56N-911 is designed to work seamlessly with multi-stage heating and cooling systems, ensuring precise temperature regulation and comfort.

Energy efficiency is a pivotal feature of the White Rodgers 1F56N-911. It includes programmable capabilities, enabling users to set schedules for different times of the day. This allows for reduced energy consumption when the home is unoccupied or during the night. Users can program up to four distinct periods within a day, ensuring that the system operates effectively while minimizing energy bills.

Additionally, the 1F56N-911 incorporates advanced technologies such as adaptive recovery and smart temperature control. Adaptive recovery allows the thermostat to learn how long it takes to heat or cool the space, initiating the system earlier to achieve the desired temperature right when needed. This feature optimizes energy use while ensuring comfort.

Another significant characteristic of this thermostat is its flexibility in installation. The device is designed for easy installation, often compatible with standard wall plates and wiring configurations, which minimizes installation time for DIY enthusiasts and professionals alike.

In conclusion, the White Rodgers 1F56N-911 thermostat combines modern technology with user-centric design. Its programmable features, adaptability across different systems, energy-saving characteristics, and ease of installation make it an excellent choice for anyone looking to improve their home's comfort and efficiency. With its reliable performance, the 1F56N-911 serves as an essential tool for effective climate control.