FULL SIZE GAS CONVECTION OVEN - GENERAL
GENERAL
INTRODUCTION
Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific.
Models
|
| FEATURES |
|
| OPTIONS |
| ||
|
|
|
|
|
|
|
|
|
MODEL | CAVITY | TEMPERATURE | DOORS | NORMAL | NORMAL | ROAST |
|
|
TIMER OR |
| BLOWER | ||||||
| DEPTH | CONTROL | (50/50) | (ROAST) | HOLD | & |
| 208/240/60/1 |
| TIMER | HOLD |
| |||||
|
|
|
| TIMER |
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
WKG | 26.5" | Mechanical (KX) | Independent 1, 2 | Optional |
| Optional | ||
WKGX | 30.5" | Mechanical (KX) | Independent 1, 2 | Optional |
| Optional | ||
WKGD | 26.5" | Solid State | Independent 1, 3 | Optional |
| Optional | ||
WKGDX | 30.5" | Solid State | Independent 1, 3 | Optional |
| Optional | ||
WKGC | 26.5" | Computer | Independent 1, 3 | Built in | Built in |
| Optional | |
|
|
|
| Digital |
|
|
|
|
WKGCX | 30.5" | Computer | Independent 1, 3 |
| Built in | Built in |
| Optional |
|
|
|
| Digital |
|
|
|
|
1.Simultaneous doors are optional (with or w/o window).
2.Stainless steel doors w/o window (standard).
3.Stainless steel doors with window (standard).
INSTALLATION
Refer to the Owner's Manual for detailed installation instructions on single or stacked ovens.
OPERATION
Refer to the Owner's Manual for specific operating instructions.
CLEANING
Refer to the Owner's Manual for specific cleaning instructions.
LUBRICATION
!Cavity blower motor has sealed bearings and requires no additional lubrication.
!Huskey’s TF1000 grease or equivalent high temperature Teflon grease.
SPECIFICATIONS
Electrical
Voltage | - | 120/60/1 |
Amps | - | 9.0 Amps |
Input BTU Rating |
| |
Natural Gas | - 44,000 | BTU input at 3.5 in. W.C. |
Propane Gas | - 44,000 | BTU input at 10.0 in. W.C. |
Gas Line Pressures
Natural - Recommend (in. W.C.) 7.0, Min 5.0
Propane - Recommend (in. W.C.) 11.0, Min 11.0 Maximum 14.0 in. W.C. (Nat. or Prop.)
TOOLS
Standard
!Standard set of hand tools.
!VOM with A.C. current tester (Any quality VOM with a sensitivity of at least 20,000 ohms per volt can be used).
!Gear Puller to remove blower
Special
!Temperature tester (thermocouple type).
!Manometer
F32700 (February 2006) |
| Page 4 of 64 |
|